JJF 1616-2017 English PDFUS$559.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1616-2017: Calibration Specification for Partial Discharge Testers Based Pulse Current Method Status: Valid
Basic dataStandard ID: JJF 1616-2017 (JJF1616-2017)Description (Translated English): Calibration Specification for Partial Discharge Testers Based Pulse Current Method Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Classification of International Standard: 17.220 Word Count Estimation: 24,275 Date of Issue: 2017-02-28 Date of Implementation: 2017-05-28 Quoted Standard: GB/T 7354-2003 Regulation (derived from): General Administration of Quality Supervision, Inspection and Quarantine No. 23 of 2017 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to the pulse current method, measuring the frequency range of 10 kHz to 500 kHz between the partial discharge tester calibration. JJF 1616-2017: Calibration Specification for Partial Discharge Testers Based Pulse Current Method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Calibration Specification for Partial Discharge Testers Based Pulse Current Method National Metrological Technical Code of the People's Republic of China Standard Specification for Calibration of Partial Discharge Tester for Pulsed Current 2017-02-28 released 2017-05-28 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Pulse current method for partial discharge tester Calibration specification Unit. National Electromagnetic Metrology Technical Committee High Pressure Metering Subcommittee Major drafting unit. National high voltage metering station State Grid Corporation of Zhejiang Electric Power Company Electric Power Research Institute Participated in the drafting unit. State Grid Jiangsu Electric Power Company Electric Power Research Institute Electric Power Research Institute of Guangxi Power Grid Co., Ltd State Grid Tianjin Electric Power Company Electric Power Research Institute State Grid Electric Power Research Institute Wuhan Nairui limited liability company This specification is commissioned by the National Electromagnetic Metrology Technical Committee of the High Pressure Metrology Subcommittee. The main drafters of this specification. Lei Min (National High Voltage Metering Station) Zhan Hongyan (State Grid Zhejiang Electric Power Company Electric Power Research Institute) Zhang jun (national high voltage metering station) Participate in the drafters. Zhou Zhicheng (State Grid Jiangsu Electric Power Company Electric Power Research Institute) Yin Liqun (Guangxi Power Grid Co., Ltd. Electric Power Research Institute) Sun Zhe (State Grid Tianjin Electric Power Company Electric Power Research Institute) Liu Yi (State Grid Electric Power Research Institute Wuhan Nairui limited liability company) table of ContentsIntroduction (Ⅲ) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Pulse current method partial discharge tester (1) 3.2 Impulse response of partial discharge tester (1) 3.3 Calibration pulse generator (1) 3.4 apparent charge (1) 3.5 Pulse resolution time (1) 3.6 pulse repetition rate (1) 3.7 Measurement Sensitivity (1) 3.8 lower limit frequency f1 and upper frequency f2 (2) 3.9 Double pulse generator (2) 4 Overview (2) 5 Metrological characteristics (3) 5.1 Upper and lower cutoff frequency (3) 5.2 Apparent charge amplitude (3) 5.3 Shift Impulse Response Gain Value (3) 5.4 Positive and negative impulse response asymmetry (3) 5.5 Low repetition rate impulse response (3) 5.6 Pulse resolution time (3) 5.7 Measurement Sensitivity (3) 5.8 pulse repetition rate (3) 5.9 Number of pulses (3) 5.10 Pulse acquisition capability (3) 5.11 Calibration pulse generator (3) 5.12 safety performance (4) 6 Calibration conditions (4) 6.1 Environmental conditions (4) 6.2 Measurement standards and other equipment (4) 7 Calibration items and calibration methods (4) 7.1 Calibration items (4) 7.2 Calibration method (5) 8 Calibration results (9) 8.1 Calibration Certificate (9) 8.2 Uncertainty Rating (9) 9 re-school time interval (9) Appendix A Cutoff Frequency and Apparent Charge Amplitude Measurement Uncertainty Evaluation Example (10) Appendix B Calibrate Original Record Format (13) Appendix C Calibration Certificate Inside Page Format (16)IntroductionThis specification is based on JJF 1071-2010 "national measurement calibration standard preparation rules", JJF 1001-2011 "pass Metrological terms and definitions ", JJF 1059.1-2012" measurement uncertainty assessment and representation "compiled from. This specification is the first release. Standard Specification for Calibration of Partial Discharge Tester for Pulsed Current1 ScopeThis specification applies to the pulsed current method, measuring the frequency range of 10kHz ~ 500kHz between the partial discharge test Calibration of the test instrument.2 reference fileThis specification refers to the following documents. Partial discharge measurement GB/T 7354-2003 For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.3 terms and units of measurementGB/T 7354-2003 Definitions and the following terms and definitions apply to this specification. 3.1 pulsed current method partial discharge tester pulsecurrentmethodbasedpartialdischargetester Through the acquisition of pulse current signal to achieve electrical equipment, local discharge measurement of special equipment. 3.2 Impulse response of partial discharge tester pulseresponseofpartialdischargetester When the measuring circuit of the partial discharge tester injects the calibration pulse signal, its corresponding pulse output is displayed. 3.3 Calibration pulse generator calibratedpulsegenerator By the voltage amplitude of U0 pulse voltage generator and the injection capacitor C0 with the composition, can produce a known charge amount q0 Of the pulse current generator. 3.4 apparent charge amount apparent charge [GB/T 7354-2003, definition 3.3.1] The apparent charge is equal to the specified test circuit, if in a very short period of time between the two sides of the sample The amount of readings on the measuring instrument is the same as that of the PD circuit itself. The apparent charge is usually used in the library (pC). 3.5 pulse resolution time pulseresolutiontime [GB/T 7354-2003, definition 3.9.5] The shortest time between successive pulses of the same duration and the same amount of charge and the same amount of charge Interval, the amplitude of the impulse response in this time interval is not greater than 10% of the amplitude of a single pulse. The pulse resolution time is generally inversely proportional to the bandwidth Δf of the measurement system and is also a measure of the system. The ability to characterize. 3.6 pulse repetition rate pulserepetitionrate [GB/T 7354-2003, definition 3.3.2] The ratio of the total number of localized pulses recorded in the selected time interval to the time interval. Note. Actually only consider the pulse above the specified amplitude or within the specified amplitude range. 3.7 Measurement sensitivity detectablesensitivity ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1616-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1616-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1616-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1616-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |