Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1583-2016 English PDF

US$439.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1583-2016: Calibration Specification for Master Meter Method Verification Facility of Compressed Natural Gas Dispenser
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1583-2016439 Add to Cart 4 days Calibration Specification for Master Meter Method Verification Facility of Compressed Natural Gas Dispenser Valid

Similar standards

JJF 1561   JJF 1406   JJF 1280   JJF 1960   JJF 1367   JJF 1593   

Basic data

Standard ID: JJF 1583-2016 (JJF1583-2016)
Description (Translated English): Calibration Specification for Master Meter Method Verification Facility of Compressed Natural Gas Dispenser
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A52
Word Count Estimation: 19,145
Date of Issue: 2016-11-25
Date of Implementation: 2017-02-25
Regulation (derived from): State Administration of Quality Supervision, Inspection and Quarantine Notice No.116 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine

JJF 1583-2016: Calibration Specification for Master Meter Method Verification Facility of Compressed Natural Gas Dispenser


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Master Meter Method Verification Facility of Compressed Natural Gas Dispenser National Metrological Technical Code of the People's Republic of China Standard table method for compressed natural gas filling machine Calibration device calibration specification 2016-11-25 release 2017-02-25 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Standard table method for compressed natural gas filling machine Calibration device calibration specification CalibrationSpecification forMasterMeter NaturalGasDisp enser Responsible Unit. National Traffic Capacity Measurement Technical Committee The main drafting unit. Chongqing Institute of Measurement and Quality Inspection Chengdu Huayu Houpu Electrical and Mechanical Equipment Co., Ltd Participated in the drafting unit. China Testing Technology Research Institute Ningbo Institute of Measurement and Testing Chongqing giant a measurement equipment Co., Ltd. Xinjiang Jin Kangda Energy Equipment Co., Ltd This specification entrusts the National Flow Capacity Measurement Technical Committee to explain The main drafters of this specification. Wang Shuo (Chongqing Institute of Measurement and Quality Inspection) Zhang Zehong (Chongqing Institute of Measurement and Quality Inspection) Zhang jun (Chengdu Huamei Houpu Electromechanical Equipment Co., Ltd.) Participate in the drafters. Zhao Pujun (China Testing Technology Research Institute) Ma Jun (Ningbo Institute of Measurement and Testing) Liu Wei (Chongqing Juchuang Measurement Equipment Co., Ltd.) Wang Jiwa (Xinjiang Jin Kangda Energy Equipment Co., Ltd.)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Units of measurement (2) 4 Overview (2) 4.1 Construction (2) 4.2 Working principle (2) 5 Metrological characteristics (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Calibration media (3) 6.3 Equipment for calibration (3) 7 Calibration items and calibration methods (3) 7.1 Calibration items (3) 7.2 Calibration method (3) 8 Expression of calibration results (7) 9 re-school time interval (7) Appendix A Reference format for calibration records (8) Appendix B Calibration Certificate (End page) Reference Format (10) Appendix C Examples of measurement uncertainty (11)

Introduction

This specification refers to International Recommendations of the International Legal Metrology Organization (OIML) R139..2007 (E) "Automotive Compression Gas fuel measurement system "(Compressedgaseousfuelmeasuringsystemsforvehicles) and the country Metrological verification procedures JJG996-2012 "Compressed natural gas filling machine", the national measurement technical specifications JJF 1369-2012 "Compressed natural gas filling machine type evaluation outline", combined with China's standard table method of natural gas filling machine calibration device Production, use and calibration of the status quo to develop, the main technical indicators and international recommendations, national measurement procedures, technology Technical specifications consistent. The terms used in this specification, except as specifically defined in this specification, use JJF 1001 "General Metrological Terms and Definition "and JJF 1004" flow meter noun terms and definitions ". According to JJF 1071-2010 "national measurement calibration standard preparation rules", the standard standard method of natural law The correction factor of the gas filling machine calibration device is the main item of the metrological calibration. This specification is the first release. Standard table method for compressed natural gas filling machine Calibration device calibration specification

1 Scope

This specification applies to the calibration of the standard table compressed natural gas filling machine.

2 reference file

JJG996-2012 compressed natural gas filling machine JJF 1369-2012 Compressed Natural Gas Filling Machine Type Evaluation Outline Automotive Compressed Natural Gas OIMLR139..2007 (E) Vehicle Compressed Gas Fuel Measurement System (Compressedgaseousfuel measuringsystemsforvehicles For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 terms and units of measurement

3.1 terminology 3.1.1 Standard table method Compression natural gas filling machine Verification device mastermetermethodverificationfacility ofcompressednaturalgasdispenser Standard equipment for calibrating or calibrating compressed gas filling machines using standard table principles (see below) Called the filling machine verification device). It includes standard tables, computer systems, pressure gauges, inlet valves, outlet valves, etc. standard Table generally use Coriolis mass flowmeter. At the same time according to the filling machine calibration device measurement range, divided into large, Medium and small flow filling machine verification device. Note. large, medium and small flow method filling machine verification device can be designed separately, can also be combined together. 3.1.2 Large flow filling machine Verification device highcapacityverificationfacilityofcompressednatural gasdispenser The maximum flow rate is greater than 70 kg/min for the filling machine of the large flow filling machine. 3.1.3 Flow filling machine Verification device mediumcapacityverificationfacilityofcompressed naturalgasdispenser The maximum flow rate is greater than 30 kg/min and not greater than that of the filling machine 70kg/min. 3.1.4 small flow filling machine verification device lowcapacityverificationfacilityofcompressednatural gasdispenser For the determination of small flow filling machine filling machine verification device, the maximum flow rate of not more than 30kg/min. 3.1.5 correction factor correctionfactor Calibration of the filling machine verification device and correction of the indication of the filling machine verification device according to the calibration result
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1583-2016_English be delivered?

Answer: Upon your order, we will start to translate JJF 1583-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1583-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1583-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.