JJF 1432-2013 English PDFUS$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1432-2013: Calibration Specification for Medical Diagnostics X-Ray Non-Invasive Exposure Time Meters Status: Valid
Basic dataStandard ID: JJF 1432-2013 (JJF1432-2013)Description (Translated English): Calibration Specification for Medical Diagnostics X-Ray Non-Invasive Exposure Time Meters Sector / Industry: Metrology & Measurement Industry Standard Word Count Estimation: 16,163 Quoted Standard: JJG 744-2004; GB 9706.3-2000; GB/T 10149-1988; YY/T 0106-2008; YY/T 0722-2009 Regulation (derived from): AQSIQ Notice No. 154 of 2013 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to: non-invasive medical diagnostic X-ray exposure schedule calibration. JJF 1432-2013: Calibration Specification for Medical Diagnostics X-Ray Non-Invasive Exposure Time Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Calibration Specification for Medical Diagnostics X-Ray Non-Invasive Exposure Time Meters People's Republic of China National Metrology Technical Specifications Non-invasive medical diagnostic X-ray exposure schedule Calibration Specification Issued on. 2013-10-25 2014-01-25 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Non-invasive medical diagnostic X-ray exposure Schedule calibration specifications osureTimeMeters Focal point. the National Technical Committee of ionizing radiation metrology The main drafting units. China Testing Technology Research Institute Participated in the drafting unit. Fujian Institute of Metrology Xinjiang Institute of Metrology Liaoning Provincial Institute of Metrology Zhejiang Institute of Metrology Shanghai Measurement and Testing Technology Research Institute This specification commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this specification. Zheng Yongming (China Testing Technology Research Institute) Liu Zhihong (China Testing Technology Research Institute) Li Jie (Fujian Institute of Metrology) Drafters participate. Mao Dingli (Zhejiang Institute of Metrology) Kang Rui (Xinjiang Institute of Measurement and Testing) Liu Jian (Liaoning Provincial Institute of Metrology) Chen Jianxin (Shanghai Institute of Measurement and Testing) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 Exposure Time (1) 3.2 Non-intrusive measurement (1) Maximum peak voltage of 3.3 (1) The average peak voltage 3.4 (1) 3.5 Radiation detection limit (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 Exposure Time (2) 5.2 Working lower radiation (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (3) 6.3 Calibration preparation work (3) 7 calibration items and calibration methods (4) 7.1 appearance and function check (4) 7.2 Calibration method (4) Expression 8 calibration results (6) 8.1 Calibration records (6) 8.2 Calibration process results (6) 9 Recalibration interval (6) Information AX-ray tube voltage load curve Appendix (7) Appendix B Calibration original record format (recommended) (8) Appendix C Measurement of Uncertainty Evaluation (9)IntroductionThis specification based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "Tong Metering term and definition of "establishment. This specification reference JJG744-2004 "Medical Diagnostic X-ray radiation" on the exposure of non-intervention schedule Technical requirements, GB 9706.3-2000 "Medical electrical equipment - Part 2. X-ray diagnostic apparatus high incidence Voltage generator for safety requirements ", YY/T 0106-2008" diagnostic X-ray machine general technical conditions "in Loading time technical requirements, YY/T 0722-2009/(IEC 61676.2002, IDT) "Medical electrical equipment Preparation of diagnostic radiology for X-ray tube voltage non-access measuring dosimetric instruments "in the access type divider About the methods of measurement. The specification for the first time to develop. Non-invasive medical diagnostic X-ray exposure schedule Calibration Specification1 ScopeThis instruction applies to non-invasive medical diagnostic X-ray exposure calibration schedule. 2. References These rules mainly cited the following documents. JJG744-2004 diagnostic X-ray radiation GB 9706.3-2000 Medical electrical equipment - Part 2. diagnostic X-ray high voltage generator occurs Requirements for the safety device GB/T 10149-1988 X-ray equipment for medical terminology and symbols YY/T 0106-2008 medical diagnostic X-ray machine general technical conditions YY/T 0722-2009/(IEC 61676.2002, IDT) Medical electrical equipment in diagnostic radiology For X-ray tube voltage non-access measuring dosimetric instruments For dated references, only the dated edition applies to this rule; undated reference documents Member, the latest edition (including any amendments) apply to this rule.3 terminology and units of measurement3.1 Exposure time exposuretime Also known as irradiation time, referring to the duration of the irradiation method prescribed measured X-ray machine, the radiation dose rate is usually Exceeds a predetermined level of the time. NOTE. The exposure time is usually based on load time measurements obtained. Loading time is measured by the method specified anode input power Rate applied to the X-ray tube time. Usually refers to the first X-ray tube voltage rises to a peak of 75% until the final descent to the phase Stop time interval of equal value. 3.2 Non-intrusive measurement of non-invasivemeasurement Analysis of the emitted radiation X-ray tube voltage is measured by. 3.3 The maximum peak voltage maximumpeakvoltage The maximum value of the X-ray tube voltage within a specified time interval, the amount of volts (V). 3.4 the average peak voltage meanpeakvoltage Within a predetermined time interval the average of all X-ray tube voltage spikes, the amount of volts (V). 3.5 Radiation detection limit X-ray detector can accurately respond to minimum air kerma rate in units of cGy/min.4 OverviewNon-intrusive medical X-ray exposure schedule, is used to measure X-ray machines for medical exposure time measuring instruments, ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1432-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1432-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1432-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1432-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |