JJF 1412-2013 English PDFUS$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1412-2013: Calibration Specification for Clinical Color Change Thermometers Status: Valid
Basic dataStandard ID: JJF 1412-2013 (JJF1412-2013)Description (Translated English): Calibration Specification for Clinical Color Change Thermometers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A54 Classification of International Standard: 17.200 Word Count Estimation: 17,165 Quoted Standard: EN 12470-2-2000 + A1-2009; ASTM E 825-1998; ASTM E 1299-1996 Regulation (derived from): AQSIQ Announcement No. 85 of 2013; Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to: measurement range of 35. 5��C ~ 42. 0��C for measuring body temperature clinical thermometer with discoloration (hereinafter referred to as the thermometer) calibration. JJF 1412-2013: Calibration Specification for Clinical Color Change Thermometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Clinical Color Change Thermometers People's Republic of China National Metrology Technical Specifications Clinical thermometer calibration with color specification Issued on. 2013-06-27 2013-09-27 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Clinical thermometer calibration with color specification eThermometers Focal point. the National Technical Committee of temperature measurement Main drafting unit. Beijing Institute of Metrology detection China Institute of Metrology Participated in the drafting unit. Liaoning Provincial Institute of Metrology People's Liberation Army General Hospital Taihe Beijing Tong Technology Development Co., Ltd. This specification commissioned the National Technical Committee is responsible for interpretation of temperature measurement The main drafters of this specification. Zhang Ke (Beijing Institute of Metrology detection) Zhang Yi farmers (Beijing Institute of Metrology detection) Chang (China Institute of Metrology) Zhang Law (Beijing Institute of Metrology detection) Drafters participate. Dong Liang (Liaoning Provincial Institute of Metrology) Zhou Juan (PLA General Hospital) Wu Shiming (Taihe Beijing Tong Technology Development Co., Ltd.) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Terms (1) 3.1 discoloration thermometer (1) 3.2 Reusable thermometers (1) 3.3 Disposable thermometer (1) 3.4 Temperature compensation value (1) 3.5 Pre-tune thermometer (1) 3.6 temperature point (1) 3.7 temperature region (2) 3.8 measurement time (2) 3.9 retention time (2) 3.10 Expiration Date (2) 4 Overview (2) 5 Metrological characteristics (2) 5.1 Temperature range (2) 5.2 division value (2) 5.3 retention time (2) 5.4 Indication error (2) 6 calibration conditions (3) Environmental conditions 6.1 (3) 6.2 measurement standard equipment and ancillary equipment (3) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration method (3) 7.3 Calibration process results (4) Expression 8 calibration results (4) 9 Recalibration interval (5) Appendix A clinical thermometer with color calibration original records (6) Appendix B clinical thermometer calibration certificate with color (inside) format (7) Appendix C thermostatic bath thermometer placed in the calibration method of operation (8) Appendix D clinical thermometer with color measurement results Uncertainty Evaluation (9)IntroductionThis specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment, where the measurement is not Evaluation is based on degree of certainty JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" in. This specification metrological characteristics of the temperature range, dividing the value, retention time and indication errors were cited EN12470-2. 2000 A1.2009 "clinical thermometer Part 2 phase change type (dot matrix) thermometers" [Clinicalther- mometers-Part 2. Phasechangetype (dotmatrix) thermometers] in 5,6.1,6.2 And 6.5. This specification calibration conditions in ambient temperature reference ASTME825-98 (Reapproved2009) "to make a one-time Intermittent measuring body temperature thermometer using phase-change "(PhaseChange-TypeDisposableFeverTher- mometerforIntermittentDeterminationofHumanTemperature) of 5.5 and ASTM E1299-96 (Reapproved2010) "Reusable intermittently measuring body temperature phase change type thermometer" (ReusablePhase-Change-TypeFeverThermometerforIntermittentDeterminationof HumanTemperature) of 5.5. EN12470-2.2000 A1.2009 measured as specified in ASTM E 825-98 covers (Reapproved2009) and ASTME1299-96 (Reapproved2010) specified measurement range, more in line with The actual situation. The specification for the first time to develop. Clinical thermometer calibration with color specification1 ScopeThis standard applies to the measurement in the range of 35.5 ℃ ~ 42.0 ℃ for measuring body temperature with a color clinical thermometer (Hereinafter referred to as a thermometer) calibration. 2. References This specification references the following documents. EN12470-2.2000 A1.2009 Clinical thermometers - Part 2 with a phase change type (dot) temperature Meter [Clinicalthermometers-Part 2. Phasechangetype (dotmatrix) thermometers] ASTME825-98 (Reapproved2009) disposable intermittent measuring body temperature of a phase change type body Thermometer (PhaseChange-TypeDisposableFeverThermometerforIntermittentDetermina- tionofHumanTemperature) ASTME1299-96 (Reapproved2010) reusable intermittently measuring the body temperature of a phase-change Thermometer (ReusablePhase-Change-TypeFeverThermometerforIntermittentDetermi- nationofHumanTemperature) For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.3 Terms3.1 discoloration thermometer colorchangethermometer Using a series of temperature-sensitive color change point status indicator to measure the temperature of the thermometer. 3.2 reusable thermometer reusablethermometer You can use many of the thermometer. Note. a maximum limit frequency of use. 3.3 Disposable thermometer disposablethermometer Use a thermometer to waste. Note. The storage temperature not higher than the lower limit of the measurement range. 3.4 Temperature compensation value temperatureoffset Temperature correction amount from the actual value and the thermometer shows the temperature of the reasons for compensating thermal conduction caused provided. [EN12470-2.2000 A1.2009 3.5] Note. The thermometer in the measurement range, only a uniform temperature compensation value. 3.5 Pre-tune thermometer preadjustedthermometer Thermometer having temperature compensation value. [EN12470-2.2000 A1.2009 3.6] 3.6 temperature point temperaturedot Spherical capsules small clinical thermometer on the different chemical composition of the mixture having a specific color temperature. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1412-2013_English be delivered?Answer: Upon your order, we will start to translate JJF 1412-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1412-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1412-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |