JJF 1385-2012 English PDFUS$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1385-2012: Calibration Specification for Flow Analyzer for Short Transient Loaded Mode of Gasoline Vehicles Status: Valid
Basic dataStandard ID: JJF 1385-2012 (JJF1385-2012)Description (Translated English): Calibration Specification for Flow Analyzer for Short Transient Loaded Mode of Gasoline Vehicles Sector / Industry: Metrology & Measurement Industry Standard Word Count Estimation: 16,137 Quoted Standard: JJG 535-2004; JJG 688-2007; JJG 1029-2007; GB 18285-2005; HJ/T 290-2006 Regulation (derived from): AQSIQ Announcement No. 212 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to gasoline vehicles short transient method using flow analyzer (hereinafter referred to as flow analyzer) calibration. JJF 1385-2012: Calibration Specification for Flow Analyzer for Short Transient Loaded Mode of Gasoline Vehicles---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Calibration Specification for Flow Analyzer for Short Transient Loaded Mode of Gasoline Vehicles People's Republic of China National Metrology Technical Specifications Gasoline Simple transient conditions with law Traffic Analyzer Calibration Specification Issued on. 2012-12-21 2013-03-21 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Gasoline Simple transient conditions with law Traffic Analyzer Calibration Specification les Focal point. the National Technical Committee of Legal Metrology measurement management Main drafting unit. Zhejiang Institute of Metrology Liaoning Provincial Institute of Metrology Participated in the drafting unit. Gansu Province Institute of Metrology Zhejiang University Oriental Technology Co., Ltd. This specification commissioned the National Technical Committee on Metering Management is responsible for interpretation of legal metrology The main drafters of this specification. Jin Yan (Zhejiang Institute of Metrology) Liu (Liaoning Provincial Institute of Metrology) Raymond (Zhejiang Institute of Metrology) Drafters participate. Ye Zhenzhou (Zhejiang Institute of Metrology) Zhang Baoguo (Liaoning Provincial Institute of Metrology) High Decheng (Gansu Province Institute of measurement) Wu Yong (Zhejiang University Oriental Technology Co., Ltd.) table of ContentsIntroduction (Ⅲ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) The oxygen concentration is diluted 3.1 (1) 3.2 standard condition (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 flow and drift (1) 5.2 flow indication error (1) 5.3 Flow Repeatability (2) 5.4 stars diluted oxygen concentration value (2) 5.5 diluted oxygen concentration indication error (2) 5.6 diluted oxygen concentration Repeatability (2) 5.7 diluted oxygen concentration response time (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (2) 7 calibration items and calibration methods (2) 7.1 flow and drift (2) 7.2 flow indication error (3) 7.3 Flow Repeatability (3) 7.4 Indication Error diluted oxygen concentration (4) 7.5 repeatability diluted oxygen concentration (4) 7.6 diluted oxygen concentration response time (5) Expression 8 calibration results (5) 9 Recalibration interval (5) Appendix A standard gas and the nominal value requirement (6) Appendix B calibration certificate (within the page) format (7) Appendix C Simple Transient method using flow analyzer flow indication Uncertainty in Measurement (8)IntroductionIn the present specification JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "Universal Measurement terms and definitions ", JJF 1059-1999" Evaluation and Expression of Uncertainty in Measurement "as the basic norms into series Row developed. This specification main reference JJG535-2004 "zirconia oxygen analyzer", JJG688-2007 "automobile exhaust gas Body Tester ", JJG1029-2007" Vortex ", GB 18285-2005" ignition engine vehicle exhaust Emission limits and measurement methods (two-speed idle conditions and simple method) "and HJ/T 290-2006" gasoline Jane Easy transient conditions exhaust emission testing equipment technical requirements "compiled. This specification is the first release. Gasoline Simple transient conditions with law Traffic Analyzer Calibration Specification1 ScopeThis instruction applies to gasoline Simple transient conditions method using flow analyzer (hereinafter referred to as flow analyzer) calibration. 2. References This specification refers to the following documents. JJG535-2004 zirconia oxygen analyzer JJG688-2007 automobile exhaust gas tester JJG1029-2007 Vortex Flowmeter GB 18285-2005 ignition engine exhaust emission limits and measurement methods (two-speed idle And BASM) HJ/T 290-2006 Simple transient conditions gasoline exhaust emission testing equipment technical requirements For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.3 terminology and units of measurementHJ/T 290-2006 and define the following terms and definitions apply to this specification. 3.1 diluted oxygen concentration dilutemixtureoxygenconcentration All the oxygen concentration of exhaust gas and ambient air mixture diluted test vehicle exhaust. 3.2 standard condition standardtemperatureandpressure Temperature 0 ℃, 101.325kPa atmospheric pressure or temperature 20 ℃, atmospheric pressure 101.325kPa state.4 OverviewTraffic Analyzer uses vortex flow measurement principle, the use of zirconia oxygen sensor was diluted concentration measurements. Traffic Analyzers set mainly by the air hose, gas collection cone tube, air pump, flow sensors, oxygen sensors diluted, dilute Release gas flow pressure sensors, temperature sensors and microprocessors and other components, used to measure the exhaust gas and petrol car ring Traffic throughout the air mixture under standard conditions (hereinafter referred to as the standard flow) and diluted oxygen concentration.5 Metrological characteristics5.1 flow and drift Traffic flow in standard state state analyzer measuring fan provided under the (95 ~ 180) L/s range Inside, within 6min flow indication drift generally not exceed ± 4L/s. 5.2 flow indication error ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1385-2012_English be delivered?Answer: Upon your order, we will start to translate JJF 1385-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1385-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1385-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |