JJF 1367-2022 English PDFUS$1639.00 · In stock
Delivery: <= 9 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1367-2022: Program of Pattern Evaluation of Thermogravimetric Moisture Meters Status: Valid JJF 1367: Historical versions
Basic dataStandard ID: JJF 1367-2022 (JJF1367-2022)Description (Translated English): Program of Pattern Evaluation of Thermogravimetric Moisture Meters Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A52 Word Count Estimation: 81,851 Date of Issue: 2022-12-07 Date of Implementation: 2023-06-07 Issuing agency(ies): State Administration for Market Regulation JJF 1367-2022: Program of Pattern Evaluation of Thermogravimetric Moisture Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.National Metrology Technical Specifications of the People's Republic of China Outline of Type Evaluation for Drying Method Moisture Meter Released on 2022-12-07 2023-06-07 Implementation Released by the State Administration for Market Regulation Outline of Type Evaluation for Drying Method Moisture Meter Replace JJF 1367-2012 Responsible unit. National Mass Density Measurement Technical Committee Main drafting unit. Shanghai Institute of Metrology and Testing Technology China Institute of Metrology Participating in the drafting unit. Jiangsu Institute of Metrology Shaanxi Institute of Metrology Sartorius (Shanghai) Trading Co., Ltd. Shanghai Tianmei Balance Instrument Co., Ltd. This specification entrusts the National Mass Density Measurement Technical Committee to be responsible for interpretation The main drafters of this specification. Zhu Jun (Shanghai Institute of Metrology and Testing Technology) Wu Di (National Institute of Metrology, China) Participating drafters. Su Yi (Shanghai Institute of Metrology and Testing Technology) Liu Wei (Jiangsu Institute of Metrology) Dong Lei (Shaanxi Institute of Metrology) Wang Bing[Sartorius (Shanghai) Trading Co., Ltd.] Huang Cheng (Shanghai Tianmei Balance Instrument Co., Ltd.) Table of contentsIntroduction (Ⅲ) 1 Scope(1) 2 References(1) 3 terms(2) 4 Overview(2) 4.1 Analog Indicating Moisture Analyzer(2) 4.2 Digital Moisture Analyzer(3) 5 Legal management requirements (3) 5.1 Units of measure(3) 5.2 Marking of accuracy class (3) 5.3 Requirements for metrological legal signs and marking of measuring instruments (3) 5.4 Requirements for installation marks (4) 5.5 Technical information to be submitted (4) 5.6 Quantity and usage of test prototype (EUT) (4) 6 Measurement Requirements(5) 6.1 Classification of accuracy levels (5) 6.2 Actual division value d (5) 6.3 Auxiliary indicating device(5) 6.4 Verification division value e (5) 6.5 The maximum permissible error of the weighing device(5) 6.6 Moisture determination error (6) 6.7 Variation due to influence magnitude and time(7) 6.8 Range Stability(8) 7 General technical requirements (8) 7.1 Appearance and structure (8) 7.2 Indication of weighing results (8) 7.3 Functional requirements (10) 7.4 Safety and reliability(11) 8 Type evaluation item list (12) 8.1 Observation and verification items (12) 8.2 Test items (14) 9 Test conditions and methods of test items (15) 9.1 Review technical documents and information (15) 9.2 Structure and file comparison(15) 9.3 Technical inspection (16) 9.4 Test equipment (16) 9.5 Test conditions (17) 9.6 Inspection of appearance and main parts (18) 9.7 Test method for analog indicating moisture analyzer (18) 9.8 Test method for digital indicating moisture analyzer (20) 10 Judgment of type evaluation results (33) Appendix A Type Evaluation Record Format (34) Appendix B Preparation of Sodium Chloride Solution (72) Appendix C Key Parts and Materials Table Format (74)IntroductionJJF 1015 "General Specification for Type Evaluation of Measuring Instruments", JJF 1016 "Guidance for Compiling Outline of Type Evaluation of Measuring Instruments" Rules", JJF 1001 "General Measurement Terms and Definitions" and JJF 1051 "Naming and Classification Codes of Measuring Instruments" It constitutes the basic series of specifications supporting the writing work of this specification. The technical indicators and test methods of this specification mainly refer to OIMLR59.2006(E) "Moisture Measurement of Grain and Oilseeds" Calibration Instrument", OIMLR76-1.2006 (E) "Non-automatic Weighing Instrument Part 1.Measurement and Technical Requirements Test", OIMLR76-2.2007 (E) "Non-automatic Weighing Instruments Part 2.Test Report" and GB/T 23111-2008 "Non-automatic Weighing Instruments Contents related to moisture, measurement performance, anti-interference performance, test procedures and record format in "Automatic Weighing Apparatus" are included in this manual. The specification is a revision of JJF 1367-2012 "Outline for Type Evaluation of Drying Moisture Meter". Compared with JJF 1367-2012, except for editorial modifications, the main technical changes of this specification are as follows. --- The relevant application classification code is given in "Scope" (see 1); ---Change "water loss rate" to "water loss rate", and add the term "water loss rate determination method", and add Add 1d/60s to determine the rate of dehydration; (see 3.7 and 3.8); --- Change "weighing device" to "weighing device"; --- Added key components and material table content (see 4.1 and 4.2); ---Deleted the regulations on the original license mark and serial number of manufacturing measuring instruments in the legal system of measurement (see 5.3.1); --- Modifications have been made to the submitted test prototype (see 5.6); --- Adjusted part e of the verification division value (see Table 2 and 6.4); --- Modify the definition of moisture measurement error (see 6.6); --- Added requirements for horizontal indicating devices (see 7.3.3); --- Deleted the requirements for electrical safety test items; ---Deleted the requirements for packaging and transportation, transportation and storage adaptability test items; --- Specific requirements for test equipment are given (see 9.4); --- Increased the sodium chloride solution standard substance, and the mass fraction of the original ratio of sodium chloride solution and sodium chloride solution The mass fraction control requirements of standard substances are uniformly U=0.03% (k=2) (see 9.4.1.2); --- Modified the calculation formula of the moisture measurement error of the analog indicating moisture analyzer (see 9.7.4); --- Change the method of "judgment of type evaluation results" to all evaluation items that are qualified to be judged as qualified (see 10); ---Modified the content of "Preparation of Sodium Chloride Solution" (see Appendix B). The release status of previous versions of this specification is as follows. ---JJF 1367-2012. Outline of Type Evaluation for Drying Method Moisture Meter1 ScopeThis type evaluation outline (hereinafter referred to as the outline) is applicable to the determination of moisture by drying method with classification code 46560500 Instrument type evaluation. The drying method moisture analyzer refers to the moisture analyzer using the weighing structure and drying heating principle, the name of the measuring instrument Such as. drying method moisture analyzer, drying method grain moisture analyzer, electronic moisture analyzer, etc.2 ReferencesThis specification references the following documents. JJG99 Weights JJG658 Drying Moisture Meter JJF 1229 Terms and Definitions of Mass Density Measurement Preparation of GB/T 601 Chemical Reagent Standard Titration Solution GB/T 2423.1 Environmental testing for electrical and electronic products - Part 2.Test methods Test A. Low temperature GB/T 2423.2 Environmental testing for electric and electronic products - Part 2.Test methods Test B. High temperature GB/T 2423.3 Environmental testing - Part 2.Test methods Test Cab. Constant damp heat test GB/T 2424.2 Damp heat test guidelines for environmental testing of electrical and electronic products GB/T 6682 Analytical laboratory water specifications and test methods GB/T 17626.2 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility Test and Measurement Technology Radio Frequency Electromagnetic Field Radiation Immunity Test GB/T 17626.4 Electromagnetic Compatibility Test and Measurement Technology Electrical Fast Transient Burst Immunity Test GB/T 17626.6 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity induced by radio frequency field GB/T 17626.11 Electromagnetic compatibility testing and measurement techniques for voltage dips, short interruptions and voltage changes Immunity test GB/T 23111-2008 Non-automatic weighing instruments and oilseeds) OIMLR76-1.2006 (E) Non-automatic weighing instruments Part 1.Measurement and technical requirements test (2006 Test) OIMLR76-2.2007 (E) Non-automatic weighing instruments Part 2.Test report (2007Non-Automatic For dated references, only the dated version applies to this specification; for undated references document, its latest version (including all amendments) applies to this specification. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1367-2022_English be delivered?Answer: Upon your order, we will start to translate JJF 1367-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 9 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1367-2022_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1367-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJF 1367-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1367-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |