JJF 1345-2012 English PDF

JJF 1345-2012_English: PDF (JJF1345-2012)
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1345-2012579 Add to Cart 5 days Calibration Specification for Cylindrical Thread Gauges Valid
JJF 1345-1990199 Add to Cart 2 days O.T.N. of Exposure Primary Standard for γ-rays Obsolete

BASIC DATA
Standard ID JJF 1345-2012 (JJF1345-2012)
Description (Translated English) Calibration Specification for Cylindrical Thread Gauges
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 25,239
Older Standard (superseded by this standard) JJG 888-1995
Quoted Standard JJF 1071-2010; GB/T 3934-2003; GB/T 14791-1993; GB/T 27025
Adopted Standard EURAMET/cg-10/v.01-2007, NEQ; DKD-R 4-3-2003, NEQ
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to symmetrical straight flank tooth type cylindrical thread gauge calibration.


JJF 1345-2012 Calibration Specification for Cylindrical Thread Gauges People's Republic of China National Metrology Technical Specifications Cylindrical thread gauge calibration specification Issued on. 2012-04-17 2012-10-17 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Cylindrical thread gauge calibration specification es Instead of JJG888-1995 Focal point. the National Technical Committee of length measuring geometry The main drafting units. China Institute of Metrology Liaoning Provincial Institute of Metrology Participated in the drafting unit. Chengdu into a tool Group Co., Ltd. This specification length measuring geometry commissioned the National Technical Committee is responsible for interpretation The main drafters of this specification. Wang farming (China Institute of Metrology) Pei Limei (China Institute of Metrology) Shizuo De (Liaoning Provincial Institute of Metrology) Zhang Yu (Liaoning Provincial Institute of Metrology) Drafters participate. Wang Ying (Chengdu into a tool Group Co., Ltd.) table of Contents Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Terms (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 Metrological characteristics and symbols (1) 5.2 Metrological characteristics calibration combination (2) 6 calibration conditions (3) Environmental conditions 6.1 (3) 6.2 standard instruments and other equipment (3) 7 calibration items and calibration methods (3) 7.1 Calibration portfolio (3) 7.2 Calibration method (3) 8 calibration results expression (7) 9 Recalibration interval (7) APPENDIX A small ring work and general purpose working ring gauge calibration (8) Appendix B Uncertainty Evaluation diameter measurement sample (9) Calculation Examples Appendix C diameter (14) Appendix D calibration records and certificates within the page format (15) Appendix E list of symbols for use in specifications (18) introduction The reference to the following specification drafting. The European Federation of National Metrology Institute (EuropeanAssociationofNationalMetrologyInstitutes) Calibration Guide. mechanical measurement gauge diameter cylindrical threaded guide (EURAMET/cg-10/v.01. Deter- minationofPitchDiameterofParalelThreadGaugesbyMechanicalProbing, July2007) German Calibration Laboratory (DKD) guide DKD-R4-3.2003 section 4.8. dimensional measuring instruments calibration Standard. threaded barrel set regulations, work regulations and master gauge calibration (RichtlinieDKD-R4-3Blatt4.8Kalibri- erenvon Messmittelnfürgeometrische Messgröβen. Kalibrierenvonzylindrischen Gewinde-Einsteldornen, Gewinde-Lehrdornenund-Prüfdornen, 2003) The specification for the revision, instead of JJG888-1995 "Cylindrical thread gauge." Compared with JJG888, in addition to editorial changes, the major technical changes are as follows. Metrological characteristics --- calibration includes only thread gauge diameter values parameters directly impact. diameter, single tooth side Angle, pitch and pitch accumulated error. Inspection of metrological characteristics, such as hardness, surface roughness, etc. are not included. --- For metrological characteristics set combinations can be calibrated clear part of the metrological characteristics according to need to select combinations. Effect --- diameter of the probe components considered by the laboratory as uncertainty depending on the method used. Cylindrical thread gauge calibration specification 1 Scope This standard applies to symmetrical straight tooth flank Cylindrical thread gauge calibration. 2. References This specification refers to the following documents. JJF 1071-2010 National Calibration Specifications writing rules GB/T 3934-2003 Technical requirements common thread gauge GB/T 14791-1993 threaded term GB/T 27025 testing and calibration laboratories General requirements For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification. 3 Terms The term cylindrical threaded see GB/T 3934-2003, GB/T 14791-1993. 4 Overview Cylindrical thread gauge is internal and external thread cylindrical element size boundary conditions for a comprehensive examination of measuring instruments, with The control elements threaded barrel limit sizes. Elements that constitute threaded barrel shown in Figure 1. Figure 1 threaded barrel elements d2- diameter; d- large diameter; d1- trails; P- pitch; α1, α2- flank angle; α- tooth type angle, α = α1 α2 Note. The figure graphics and symbols apply to external threads. Internal thread diameter, large diameter, small diameter symbols are denoted as D2, D, D1, the same as the rest of the external thread. 5 Metrological characteristics 5.1 Metrological characteristics and symbols Metrological characteristics and symbols shown in Table 1. ......

Similar standards: JJF 1561   JJF 1406   JJF 1280   JJF 1349   JJF 1350   JJF 1347