Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1309-2011 English PDF

US$669.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1309-2011: Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Status: Valid

JJF 1309: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1309-2011669 Add to Cart 5 days Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement Valid
JJF 1309-1990239 Add to Cart 2 days O.T.N. of Atomic Time Scale Primary Standard Obsolete

Similar standards

JJF 1366   JJF 1187   JJF 1107   JJF 2019   JJF 1908   JJF 1308   

Basic data

Standard ID: JJF 1309-2011 (JJF1309-2011)
Description (Translated English): Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A54
Classification of International Standard: 17.200
Word Count Estimation: 29,231
Date of Issue: 2011-09-14
Date of Implementation: 2011-12-14
Quoted Standard: JJG 617-1996; GB/T 16839.2-1997; JB/T 8622-1997; JB/T 8623-1997
Regulation (derived from): AQSIQ Announcement No. 134 of 2011
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard applies to the calibration temperature calibration. Temperature Calibrator can be connected with RTD or thermocouple to measure the temperature, you can also simulate thermal resistance, thermocouple, or the output of the process signal calibration temperature secondary instrument. Temperature Calibrator (hereinafter referred to as calibrator) can be a part of the multi-function calibrator.

JJF 1309-2011: Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification of Temperature Indicators and Simulators by Electrical Simulation and Measurement People's Republic of China National Metrology Technical Specifications Temperature Calibrator calibration specifications Issued on. 2011-09-14 2011-12-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Temperature Calibrator calibration specifications This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 14, 2011, and from From December 14, 2011 into effect. Focal point. the National Technical Committee of temperature measurement Main drafting unit. Shanghai Institute of Measurement and Testing Participated in the drafting unit. China Testing Technology Research Institute Dalian metrological verification tests Beijing Const Instrument Technology Co., Ltd. Shandong Province Institute of Metrology Hebei Academy of Supervision and Testing This specification commissioned the National Technical Committee is responsible for interpretation of temperature measurement The main drafters of this specification. Zhu Jialiang (Shanghai Institute of Measurement and Testing) Cui Ling Yan (Shanghai Institute of Measurement and Testing) Drafters participate. EDUCATION JOURNAL (China Testing Technology Research Institute) Li Ying (Dalian metrological verification tests) Liu Baoqi (Beijing Const Instruments Technology Co., Ltd.) Sun Shulan (Shandong Province Institute of Metrology) Liu Hongyan (Hebei Supervision and Testing Institute)

table of Contents

1 Scope (1) 2. References (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 indication error (1) 4.2 output error (2) 4.3 analog RTD excitation current effective range (2) The minimum temperature in steps of 4.4 output (2) Calibration Condition 5 (2) 5.1 standard devices and other equipment (2) Environmental conditions 5.2 (3) 5.3 Power (3) 6 calibration items and calibration methods (3) 6.1 calibration items (3) 6.2 Calibration method (3) 6.3 Data Processing principle (7) Expression 7 Calibration results (7) 8 Recalibration interval (8) A wire compensation calibration method Appendix (9) Appendix B Calibration temperature calibrator original record format (13) Appendix C Temperature Calibrator Error in Measurement of Uncertainty Evaluation (15) Appendix D Temperature Calibrator output error measurement results Uncertainty Evaluation (18) Appendix E thermal resistance of the differential resistance and thermocouple Seebeck coefficient (21) Appendix F Calibration Certificate-page format (23) Temperature Calibrator calibration specifications

1 Scope

This standard applies to the calibration temperature calibration. Temperature Calibrator can be connected with RTD or thermocouple to measure the temperature Degree, can also simulate RTD or thermocouple output process signals to calibrate the temperature of the secondary instrument. Temperature Calibrator (hereinafter referred to as the calibrator) can be part of the multi-function calibrator. 2. References This specification references the following documents. JJG617-1996 Digital Temperature Indicators and Controllers GB/T 16839.2-1997 Thermocouples - Part 2. Tolerances JB/T 8622-1997 industrial platinum RTD Technical conditions and indexing table JB/T 8623-1997 industrial copper heat resistance Technical conditions and indexing table For dated references, only the edition date of application of this specification, cited documents without a date, The latest version (including any amendments) applies to this specification.

3 Overview

Calibrator has two functions and output measurements, temperature measuring instruments belonging to the multifunction measuring instruments. Calibrator It can be measured and simulated thermal resistance type usually Pt100, Pt500, Pt1000, Cu50, Cu100 and so on; measuring Type thermocouple simulation and usually B, S, R, K, N, E, J, T, etc; DC analog signal output from the process Current is 4mA ~ 20mA or dc voltage of 1V ~ 5V and the like. When the calibrator is set in the measurement mode, you can connect with RTD or thermocouple to measure the temperature, the equivalent of a number Word temperature indicator. Calibrator when connecting thermocouples to measure temperature, usually having a built-in reference junction temperature compensation function automatically Can, it can not directly connected with the external thermocouple cold junction compensator. Some calibrator manual switching compensation. When you set the calibrator output state can simulate a variety of thermal resistance, thermocouple temperature transmitter output and the corresponding Standard electrical signal to calibrate the temperature of the secondary instrument. Usually in the form of the numeric keypad to set the analog temperature value, can also be used Increasing or decreasing the minimum temperature in a stepwise manner to apply to analog temperature secondary instrument calibration. Calibrator thermoelectric simulation Dual output, usually a reference junction temperature automatic compensation function, the output was simulated thermocouple reference junction temperature Potential output terminal temperatures. Some calibrator manual switching compensation. RTD and thermocouple simulation, correspondence and the corresponding relationship between temperature and resistance temperature and potential are to follow GB/T 16839.2-1997, JB/T 8622-1997, JB/T 8623-1997 standards.

4 Metrological characteristics

4.1 Indication error Calibrator set in the measurement state, as the use of digital temperature indicator, which shows the difference between the input value and the standard value for the Indication error calibrator. The maximum permissible error indication will usually not exceed ± (0.01 ~ 0.6) ℃.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1309-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1309-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1309-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1309-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1309-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1309-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.