Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1300-2011 English PDF

US$599.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1300-2011: Program of Pattern Evaluation of Pendulum Impact Testing Machines
Status: Valid

JJF 1300: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1300-2011599 Add to Cart 5 days Program of Pattern Evaluation of Pendulum Impact Testing Machines Valid
JJF 1300-1990239 Add to Cart 2 days O.T.N. of 3cm,5cm Attenuation Primary Standard Obsolete

Similar standards

GB/T 36126   JJF 1368   GB/T 1885   JJF 1296.1   JJF 1296.2   JJF 1295   

Basic data

Standard ID: JJF 1300-2011 (JJF1300-2011)
Description (Translated English): Program of Pattern Evaluation of Pendulum Impact Testing Machines
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A53
Classification of International Standard: 17.100
Word Count Estimation: 26,238
Date of Issue: 2011-07-28
Date of Implementation: 2011-10-28
Quoted Standard: JJG 145-2007; JJF 1011-2006; GB/T 229-2007; GB/T 2611-2007; GB/T 3808-2002; GB 5226.1-2008
Regulation (derived from): AQSIQ Announcement No. 118 of 2011
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard applies to metallic materials Charpy impact test machine (hereinafter referred to as tester) the type of evaluation can also be used to guide the production process of product quality supervision and inspection.

JJF 1300-2011: Program of Pattern Evaluation of Pendulum Impact Testing Machines

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Pendulum Impact Testing Machines People's Republic of China National Metrology Technical Specifications Charpy impact testing machine model evaluation outline Issued on. 2011-07-28 2011-10-28 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Charpy impact testing machine model Assessment outline Machines This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on July 28, 2011, and from From October 28, 2011 into effect. Focal point. the National Technical Committee on Metering hardness force value Main drafting unit. Iron and Steel Institute Participated in the drafting. Wuzhong Material Testing Machine Co., Ltd. Tenneco Beijing Analytical Instrument Co., Ltd. Hubei Provincial Institute of Measurement and Testing This specification hardness values measured by the National Technical Committee of the force responsible for the interpretation The main drafters of this specification. Zhou Wei Song (Iron and Steel Research Institute) Chen Wu (Iron and Steel Research Institute) Drafters participate. Wang Peking (Wuzhong Material Testing Machine Co., Ltd.) Chunhua (Iron and Steel Research Institute) Zhangzhuang (Tenneco Beijing Analytical Instruments Co., Ltd.) Hu Xiang (Hubei Institute of Measurement and Testing)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Terms, definitions and symbols (1) 3.1 Terms and definitions (1) Symbols 3.2 (1) 4 Overview (2) 4.1 Purpose and principles (2) 4.2 Structure (2) 5 legal management requirements (3) 5.1 Units of measurement requirements (3) 5.2 accuracy requirements (3) 5.3 legal metrology requirements for marking and identification of measuring instruments (3) Technical information and test prototype to be submitted by the applicant 5.4 (3) 6 measurement requirements (4) 6.1 Test machine frame (4) 6.2 pendulum (4) 6.3 and anvil holder (5) 6.4 indicating means (5) 6.5 Use standard sample indirect test (5) 7 General Requirements (6) 7.1 General Requirements (6) 7.2 Electrical Equipment (6) 7.3 jolt resistance to transport performance (6) 7.4 Other requirements (6) 8 Type Evaluation Project (6) Test conditions and test items 9 (7) 9.1 Test Purposes (7) 9.2 Test conditions (7) 9.3 Test Method (8) Determination (12) 10 type of evaluation results 11 original record format type evaluation (12) Appendix A measuring instrument type evaluation original record format (13) Appendix B part of the testing machine (16) Appendix C impact test machine cutting, the specimen holder and the anvil (17) Appendix D work and structure of the specimen bearing tester anvil (19) Appendix E initial potential energy measurement (20) Charpy impact testing machine model evaluation outline

1 Scope

This outline is applied to the metal material Charpy impact test machine (hereinafter referred to as the tester) the type of evaluation can also be used To guide the production process of product quality supervision and inspection.

2 Citations

JJG145-2007 Charpy impact test machine JJF 1011-2006 force value and hardness measurement terms and definitions GB/T 229-2007 metallic materials - Charpy pendulum impact test method GB/T 2611-2007 General requirements for testing machines GB/T 3808-2002 pendulum impact testing machines GB 5226.1-2008/IEC 60204-1.2005 Safety of machinery - Electrical machinery and electrical equipment - Part 1. General technical conditions These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this syllabus, however, the drum Reed whether the latest versions of these files according to the parties that this outline agreement. Those who do not note cited date Use, the latest versions apply to this outline. 3 Terms, definitions and symbols 3.1 Terms and Definitions GB/T 229, the terms and definitions GB/T 3808 and JJG145 defined apply to this outline. 3.2 Symbol Symbols used in this syllabus, units and are described in Table 1. Table 1 Symbols, units and description Symbol Unit Description KN J nominal energy KP J actual initial potential energy (potential energy) KR J energy standard KS J indicative energy KV J absorbed energy Hold the specimen holder and the K1 or β1 J or degree (°) of normal operation, the tester indicates the energy or lift angle K2 or β2 J or degree (°) Hold on the sample holder, and the pointing device is not reset when the tester indicates normal operation of energy Or lead angle
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1300-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1300-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1300-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1300-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1300-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1300-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.