Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1287-2011: Calibration Specification for Clarity Test Equipment Status: Valid JJF 1287: Historical versions
Basic dataStandard ID: JJF 1287-2011 (JJF1287-2011)Description (Translated English): Calibration Specification for Clarity Test Equipment Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A60 Classification of International Standard: 17.180 Word Count Estimation: 14,156 Date of Issue: 2011-06-14 Date of Implementation: 2011-09-14 Quoted Standard: JJG 245-2005; Chinese Pharmacopoeia (2010 edition) Regulation (derived from): AQSIQ Announcement No. 90 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to visible foreign matter Inspection Act (light inspection method) for clarity detector calibration. JJF 1287-2011: Calibration Specification for Clarity Test Equipment---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Clarity Test Equipment People's Republic of China National Metrology Technical Specifications Clarity detector calibration specification Issued on. 2011-06-14 2011-09-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Clarity detector calibration specification TestEquip ment This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on June 14, 2011, and from From September 14, 2011 into effect. Focal point. the National Technical Committee on Optical metrology Main drafting unit. Liaoning Provincial Institute of Metrology China Testing Technology Research Institute Participated in the drafting unit. China Institute of Metrology This specification committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this specification. Aiming Ze (Liaoning Provincial Institute of Metrology) Li Xiaobin (China Testing Technology Research Institute) Zhang Mei (Liaoning Provincial Institute of Metrology) Drafters participate. Jiang Xiaomei (China Institute of Metrology) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (2) Calibration Condition 5 (2) 5.1 Calibration environmental conditions (2) 5.2 Calibration Equipment (2) 6 calibration items and calibration methods (2) 6.1 Calibration before the test (2) The relative error of 6.2 Indication of illumination (2) 6.3 Uniformity light source (3) 6.4 Stability of the light source (3) 6.5 Timer indication error (3) 7 Calibration Results The expression (3) 8 Recalibration interval (4) Appendix A Measurement Uncertainty Example (5) Appendix B Calibration record format (7) Appendix C calibration certificate page format (9) Clarity detector calibration specification1 ScopeThis instruction applies to visible foreign matter inspection method (light detection method) of clarity detector calibration.2 CitationsThis specification references the following documents. JJG245-2005 light meter People's Republic of China Pharmacopoeia (2010 edition) When using this specification it should be noted that using the currently valid version of the documents cited.3 OverviewVisible foreign matter is present in injections, ophthalmic pharmaceutical preparations in a liquid solution, under specified conditions, can be visually In observed insoluble material, typically having a particle size or length greater than 50μm. Clarity detector is based on light inspection method using visual methods, within the time specified in the illuminance and provisions, respectively In black and white background of the instruments to detect visible foreign matter. Clarity light detector system consists of a dedicated trichromatic illumination continuously adjustable fluorescent lamp composed of digital photos Meter part (the photoreceptor), time control systems. Figure 1 schematic clarity detector A- with a fluorescent light shading plate; B- reflective white background (the inside of the visor); C- non-reflective black background; D- white background and is not reflective of the bottom (for checking colored foreign matter); G- time display section; H- illumination display portion; E- one (or two) Illuminometers; F- clarity illuminance detector probe ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1287-2011_English be delivered?Answer: Upon your order, we will start to translate JJF 1287-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1287-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1287-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJF 1287-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1287-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |