Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1285-2011 English PDF

US$509.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1285-2011: Calibration specification for surface resistance tester
Status: Valid

JJF 1285: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1285-2011509 Add to Cart 4 days Calibration specification for surface resistance tester Valid
JJF 1285-1990199 Add to Cart 2 days O.T.N.for D.C Resistance Primary Standard Obsolete

Similar standards

JJF 1234   JJF 1366   JJG 376   JJF 2000   JJF 1293   JJF 1284   

Basic data

Standard ID: JJF 1285-2011 (JJF1285-2011)
Description (Translated English): Calibration specification for surface resistance tester
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A55
Classification of International Standard: 17.220
Word Count Estimation: 22,215
Date of Issue: 2011-06-14
Date of Implementation: 2011-09-14
Quoted Standard: JJF 1001-1998; JJF 1059-1999; JJF 1094-2002; JJF 690-2003; GB/T 1410-2006; GB/T 10064-2006; IEC 61340-4-1-2003; ANSI/ESD S7.1- 2005
Regulation (derived from): ?AQSIQ Announcement 2011 No.90;
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard applies to the measurement of anti-static surface resistance of the surface resistance tester (hereinafter referred to as the tester) for calibration. This specification does not apply to other uses of the surface resistance tester calibration.

JJF 1285-2011: Calibration specification for surface resistance tester

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for surface resistance tester People's Republic of China National Metrology Technical Specifications Surface resistance tester calibration specification Issued on. 2011-06-14 2011-09-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Surface resistance tester Calibration Specification This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on June 14, 2011, and from From September 14, 2011 into effect. Focal point. the National Technical Committee on Electromagnetic measurement Main drafting unit. Jiangsu Province Institute of Metrology China Institute of Metrology Participated in the drafting. Guangdong Institute of Metrology Zhejiang Institute of Metrology Guilin Institute of Electrical Science Changzhou Tonghui Electronic Co., Ltd. This specification by the responsible National Technical Committee Electromagnetic measurement interpretation The main drafters of this procedure. Fan Yi (Jiangsu Province Institute of Metrology) Shao Haiming (China Institute of Metrology) Li Wenjie (Jiangsu Province Institute of Metrology) Drafters participate. Luo Xudong (Guangdong Institute of Metrology) Luo Jin (Zhejiang Institute of Metrology) Xuemin (Guilin Electric Institute of Science) Zhao Haohua (Changzhou Tonghui Electronic Co., Ltd.)

table of Contents

1 Scope (1) 2. References (1) 3 Terminology (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 resistance measurement basic error (2) 5.2 The maximum permissible error open circuit voltage (3) 5.3 the basic requirements of the measuring electrode (3) 5.4 Safety Performance requirements (3) 6 calibration conditions (3) Environmental conditions 6.1 (3) 6.2 standards and other measuring equipment (3) 7 calibration items and calibration methods (4) 7.1 calibration items (4) 7.2 Calibration method (4) 8 calibration results (7) 9 Recalibration interval (7) Appendix A light-emitting diode display basic parameters tester (8) Appendix B surface resistance tester (digital) calibration records (9) Appendix C surface resistance tester (analog) calibration records (11) Appendix D surface resistance tester (LED) calibration records (13) Appendix E calibration certificate-page format (digital) (14) Appendix F Calibration Certificate-page format (analog) (15) Appendix G calibration certificate within the page format (LED) (16) Surface resistance tester calibration specification

1 Scope

This standard applies to the measurement of anti-static surface resistance of the surface resistance tester (hereinafter referred to as the tester) school quasi. This specification does not apply to other uses of surface resistance tester calibration. 2. References This specification references the following documents. JJF 1001-1998 common measurement terms and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 measuring instrument characteristics evaluation JJG690-2003 high insulation resistance meter (megger) test procedures GB/T 1410-2006/IEC 60093. 1980 Solid volume resistivity of insulating materials and surface resistivity test method GB/T 10064-2006/IEC 60167. 1964 Standard Test Method for Determination of insulation resistance of solid insulating materials IEC 61340-4-1.2003 floor covering and flooring installed Standard Test Method for Resistance ANSI/ESD-S7.1-2005 anti-static flooring material properties When using this specification should be taken in the current valid version of the above referenced files.

3 Terminology

3.1 surface resistance surfaceresistance In between the two electrodes of the sample surface the applied voltage and the power of time specified in the current flowing through the quotient between the two electrodes. Polarized in the two electrodes may be formed negligible. Note. The normal current flows mainly through a surface layer of the sample, but also flows through the components within the sample volume. 3.2 electrode electrodes Electrode testing equipment is generally used for communication with the test sample and to the sample collection device related information. this Specification tester electrode conductor has a certain shape, size and weight of the sample in contact.

4 Overview

Surface resistance tester is used to measure anti-static objects (such as. floors, work surfaces, clothing, etc.) surface resistance The special test equipment, the test voltage is generally 250V, 100V and 10V (or 9V) and the like. Surface resistance tester method commonly used at both ends of the electrode between the measured surface resistance was measured to determine The surface resistance value of the object. The measurement electrode is generally shaped hammer (hammer) electrode, which has a digital display Display Shows, the bar graph and a light emitting diode (LED) display. Digital display, an analog tester by measuring pointer displayed after the measured surface (resistance) applied voltage Generating current size, to determine the surface resistance value of the object by means of operation. Mainly by the test power, zoom
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1285-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1285-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1285-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1285-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1285-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1285-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.