Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1268-2010: Calibration Specification for Medical Diagnostical X-ray Radiation Source for Computer Tomography (CT) Phantom Status: Valid JJF 1268: Historical versions
Basic dataStandard ID: JJF 1268-2010 (JJF1268-2010)Description (Translated English): Calibration Specification for Medical Diagnostical X-ray Radiation Source for Computer Tomography (CT) Phantom Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 12,112 Date of Issue: 2010-12-30 Date of Implementation: 2011-04-01 Quoted Standard: AAPM REPORT NO.39; GB/T 17006-1997; GB/T 17589-1998 Regulation (derived from): State Administration of Quality Supervision, Inspection and Quarantine Notice No. 3 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to medical X-ray CT phantom calibration, the voltage range of 80kV ~ 140kV. JJF 1268-2010: Calibration Specification for Medical Diagnostical X-ray Radiation Source for Computer Tomography (CT) Phantom---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Calibration Specification for Medical Diagnostical X-ray Radiation Source for Computer Tomography (CT) Phantom People's Republic of China National Metrology Technical Specifications Medical X-ray CT calibration phantom Specification ComputerTomography (CT) Phantom Issued on. 2010-12-30 2011-04-01 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical X-ray CT calibration phantom Specification (CT) Phantom This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on December 30, 2010, and from From April 1, 2011 implementation. Focal point. the National Technical Committee of ionizing radiation metrology Drafting units. China Institute of Metrology Xuanwu Hospital This specification commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this specification. Li Xingdong (China Institute of Metrology) Pengming Chen (Xuanwu Hospital) Wu Huili (China Institute of Metrology) Drafters participate. Wan National Day (China Institute of Metrology) White gold (Xuanwu Hospital) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 aperture resolution module (or trash rack width) and its deviation interval size (1) Stability 4.2 CT value (1) Calibration Condition 5 (2) 5.1 standard module group (2) 5.2 CT phantom calibration device (2) 5.3 Calibration environmental conditions (2) 6 calibration items and calibration methods (3) 6.1 General inspection (3) 6.2 aperture width or bias-irons (3) 6.3 CT value and stability (3) 7 Calibration Results The expression (4) 8 Recalibration interval (4) Appendix A resolution module aperture or gate finger width calibration uncertainty analysis (5) Appendix B calibration certificate contents (7) Medical X-ray CT calibration phantom Specification1 ScopeThis standard applies to medical X-ray CT calibration phantom, the voltage range of 80kV ~ 140kV.2 CitationsThis specification references the following documents. [1] AAPMReportNo.39Specificationandacceptancetestingofcomputedtomo- graphyscanners (Report No. AAPM39 computer tomography device acceptance test procedure described in detail) Evaluation [2] GB/T 17006-1997 medical imaging departments and routine testing - Part 2-6. X-ray Computer tomography apparatus stability test [3] GB/T 17589-1998 X-ray computed tomography apparatus of image quality assurance testing standards When using this specification it should be noted that using the currently valid version of the documents cited.3 OverviewCT imaging for medical testing and evaluation of the physical parameters of the die body (hereinafter referred to as CT phantom) generally consists of water on module empty Resolution between modules, module density resolution, slice thickness and CT value linear modules and other components (or components) components. respectively CT imaging for the detection of water in CT values and their uniformity and noise, spatial resolution, density resolution, slice thickness, The accuracy of CT values and other indicators. Now see there are two categories, based on water as a homogeneous medium performance phantom (water phantom), the other is Water equivalent of organic material is a homogeneous medium performance phantom (water equivalent solid mold).4 Metrological characteristicsAperture 4.1 Resolution module (or trash rack width) and the size of the deviation interval Performance measurement aperture (or trash rack width) and the size of the resolution module spacing requirements in Table 1. Table 1 resolution metrology module size requirements Modular form Square hole gridlines The long interval measurement site side aperture spacing wide spacing Deviation ± 0.05mm Stability 4.2 CT values In determining the energy condition, it recalibrated stability of each material cycle of CT values (hereinafter referred to as stability) See Table 2. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1268-2010_English be delivered?Answer: Upon your order, we will start to translate JJF 1268-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1268-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1268-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJF 1268-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1268-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |