Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1261.19-2017 English PDF

US$809.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1261.19-2017: Rules of Metrology Testing for Energy Efficiency of AC Electric Fans
Status: Valid

JJF 1261.19: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1261.19-2017809 Add to Cart 6 days Rules of Metrology Testing for Energy Efficiency of AC Electric Fans Valid
JJF 1261.19-2015RFQ ASK 5 days Rules of Metrology Testing for Energy Efficiency of A.C. Electric Fans Obsolete

Similar standards

JJF 1016   JJF 1059.1   JJF 1071   JJF 1261.10   JJF 1261.5   JJF 1261.27   

Basic data

Standard ID: JJF 1261.19-2017 (JJF1261.19-2017)
Description (Translated English): Rules of Metrology Testing for Energy Efficiency of AC Electric Fans
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A50
Classification of International Standard: 17.020
Word Count Estimation: 35,399
Date of Issue: 2017-09-26
Date of Implementation: 2018-03-26
Older Standard (superseded by this standard): JJF 1261.19-2015
Quoted Standard: JJF 1261.1-2017; GB/T 2829-2002; GB 4706.1-2005; GB 12021.9-2008; GB/T 13380-2007
Regulation (derived from): General Administration of State Quality Inspection Announcement 2017 No. 78
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard stipulates the requirements for energy efficiency measurement, measurement and testing procedures, measurement and detection methods, measurement and evaluation criteria, and test reports for AC electric fans (hereinafter referred to as electric fans). This standard applies to single-phase rated voltage does not exceed 250V, other rated voltage does not exceed 480V, driven by the AC motor fan, wall fan, table fan, floor fan, ceiling fan, rotary fan energy efficiency measurement supervision and inspection, commissioned testing Can refer to this standard. Units that produce and sell electric fans can also use this standard for testing. The electric fan that is tested should be a product that the manufacturer has passed its own inspection, or it is a product imported or sold by the seller.

JJF 1261.19-2017: Rules of Metrology Testing for Energy Efficiency of AC Electric Fans

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules of Metrology Testing for Energy Efficiency of AC Electric Fans People's Republic of China National Metrology Technical Specifications AC fan energy efficiency Metering detection rules Published on.2017-09-26 2018-03-26 implementation The State Administration of Quality Supervision, Inspection and Quarantine issued AC fan energy efficiency Metering detection rules Replacing JJF 1261.19-2015 Key units. National Legal Measurement Management and Measurement Technology Committee Energy Efficiency Marking Measurement Inspection Sub-Technical Committee Drafted by. Anhui Provincial Academy of Metrology Hefei University of Technology Participated in drafting. Jiangsu Academy of Metrology China Household Appliances Research Institute Zhuhai Gree Electric Co., Ltd. This Code entrusts the National Legal System Measurement Management Technical Committee to measure the efficiency of energy efficiency labeling Technical Committee is responsible for explaining The main drafters of this specification. Zhang Xiaojun (Anhui Provincial Institute of Metrology) Wu Jun (Anhui Provincial Institute of Metrology) Cheng Yinbao (Hefei University of Technology) Participating drafters. Shao Yuda (Jiangsu Institute of Metrology Science) Yu Ling (China Household Electrical Appliances Research Institute) Zhang Zhaoming (China Household Electrical Appliances Research Institute) Chen Jin (Zhuhai Gree Electric Appliance Co., Ltd.)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Terms and units of measure (1) 3.1 Rated input power (1) 3.2 Output Air Volume (1) 3.3 AC fan energy efficiency (1) 3.4 AC fan energy efficiency limit (1) 3.5 Energy efficiency rating (1) 4 Overview (2) 5 Metrological requirements (2) 5.1 Energy Efficiency Labelling (2) 5.2 Energy Efficiency Index (Energy Consumption) (2) 5.3 Energy efficiency rating (3) 6 Testing Conditions (4) 6.1 Environmental Conditions (4) 6.2 Measuring Equipment (4) 6.3 Measurement uncertainty (5) 7 Testing Items and Methods (5) 7.1 Sampling Principles and Methods (5) 7.2 Sample Testing (5) 7.3 Original records (6) 7.4 Data Processing (6) 8 Test Results (6) 8.1 Eligibility Criteria for Energy Efficiency Index (Energy Consumption) Measurement Test Results (6) 8.2 Test results assessment criteria (6) 8.3 Test Report (7) Appendix A AC Fan Measurement Method (9) Appendix B Examples of Evaluation of Uncertainty in Measurement of AC Fan Energy Efficiency (15) Appendix C AC Fan Energy Efficiency Measurement Inspection Sample Sheet (Format) (22) Appendix D Original Record of AC Fan Energy Efficiency Measurement (Format) (23) Appendix E AC Fan Energy Efficiency Measurement Test Report (Format) (26)

Introduction

In order to standardize the energy efficiency measurement of AC fans implementing energy efficiency label management (hereinafter referred to as “fans”) The inspection work is based on the requirements of JJF 1261.1-2017 Energy Efficiency Measurement and Detection Rules for Energy Products. specification. This specification replaces JJF 1261.19-2015, compared with JJF 1261.19-2015, except for editorial changes. The main changes are as follows. --- "5.1 Energy efficiency labeling" adds "energy efficiency information code" and "energy efficiency 'leader' information" And other requirements; --- The original record format and test report format were revised accordingly (Appendix D, Appendix E). The previous versions of this specification were issued as follows. ---JJF 1261.19-2015. AC fan energy efficiency Metering detection rules

1 Scope

This specification stipulates the requirements for energy efficiency measurement and measurement of AC electric fans (hereinafter referred to as electric fans). Sequence, measurement and measurement methods, measurement criteria, and test reports. This specification applies to single phase rated voltage not exceeding 250V, other rated voltage not exceeding 480V, by alternating current Motive-driven metering supervision and inspection of energy-driven table fans, wall fans, table fans, floor fans, ceiling fans, and rotating pages The test can be carried out with reference to this specification. Units that manufacture and sell electric fans can also be tested in accordance with this specification. The electric fan that is tested should be a product that the manufacturer has passed its own inspection, or it is a product imported or sold by the seller.

2 references

This specification refers to the following documents. JJF 1261.1-2017 Energy Product Energy Efficiency Measurement Inspection Rules GB/T 2829-2002 Periodic Inspection Count Sampling Procedures and Tables (Applicable to Inspection of Process Stability) GB 4706.1-2005 Safety of household and similar electrical appliances Part 1. General requirements GB 12021.9-2008 AC fan energy efficiency limit and energy efficiency rating GB/T 13380-2007 AC fans and governors For dated references, only dated editions apply to this specification; all undated references The latest version (including all amendments) applies to this specification.

3 Terms and units of measure

The following terms and units of measurement apply to this specification. 3.1 Rated input power ratedpowerinput The input power specified by the manufacturer for the fan, measured in W. 3.2 Output air outputofair The amount of air output per minute when the fan operates at the rated voltage, rated frequency, and maximum speed. The unit of measurement is m3/min. 3.3 AC fan energy efficiency valuesofenergyefficiencyforACelectricfans When measured at rated voltage, rated frequency and maximum speed, the measured output air volume is divided by the measured input power. Rate, the unit of measurement is m3/(min·W). 3.4 AC fan energy efficiency limit value minimumalowablevaluesofenergyefficiencyforACe- Lectricfans This specification specifies the minimum allowable energy efficiency value of AC fans under test conditions, and the unit of measurement is m3/(min·W). 3.5 Energy efficiency grade energyefficiencygrades A graded method of indicating the level of energy efficiency of AC fans, with the highest rating at Level 1 and Level 3 lowest.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1261.19-2017_English be delivered?

Answer: Upon your order, we will start to translate JJF 1261.19-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1261.19-2017_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1261.19-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1261.19-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1261.19-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.