JJF 1261.11-2017 English PDFUS$899.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1261.11-2017: Rules of Metrology Testing for Energy Efficiency of Domestic Solar Water Heating Systems Status: Valid JJF 1261.11: Historical versions
Basic dataStandard ID: JJF 1261.11-2017 (JJF1261.11-2017)Description (Translated English): Rules of Metrology Testing for Energy Efficiency of Domestic Solar Water Heating Systems Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A50 Classification of International Standard: 17.020 Word Count Estimation: 39,310 Date of Issue: 2017-09-26 Date of Implementation: 2018-03-26 Older Standard (superseded by this standard): JJF 1261.11-2013 Quoted Standard: JJF 1261.1-2017; GB/T 2829-2002; GB/T 12936; GB/T 18708; GB/T 19141; GB 26969-2011; GB/T 26970 Regulation (derived from): General Administration of State Quality Inspection Announcement 2017 No. 78 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard specifies the energy efficiency measurement requirements, metrological testing procedures, metrological testing methods, criteria for the assessment of measurement results, and test reports for household solar water heating systems with a hot water storage tank capacity of less than 0.6 m3. This standard is applicable to the measurement and supervision of energy efficiency of domestic solar hot water systems with a capacity of hot water storage tank below 0.6m3. The entrusted inspection may refer to this standard. Units that produce and sell domestic solar hot water systems may also be tested in accordance with this standard. The home solar hot water system that is tested should be a product that the producer has passed the inspection of, or is a product that the seller imports or sells. JJF 1261.11-2017: Rules of Metrology Testing for Energy Efficiency of Domestic Solar Water Heating Systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Rules of Metrology Testing for Energy Efficiency of Domestic Solar Water Heating Systems People's Republic of China National Metrology Technical Specifications Home solar hot water system Energy efficiency measurement rules Published on.2017-09-26 2018-03-26 implementation The State Administration of Quality Supervision, Inspection and Quarantine issued Home solar hot water system Energy efficiency measurement rules Replacing JJF 1261.11-2013 Key units. National Legal Measurement Management and Measurement Technology Committee Energy Efficiency Marking Measurement Inspection Sub-Technical Committee Drafted by. Hubei Institute of Metrology and Measurement Technology China Institute of Metrology Participated in the drafting. Huang Ming Solar Energy Co., Ltd. China Quality Certification Center Wuhan Branch Beijing Institute of Metrology and Detection Shanghai Institute of Metrology and Measurement Technology This Code entrusts the National Legal System Measurement Management Technical Committee to measure the efficiency of energy efficiency labeling Technical Committee is responsible for explaining The main drafters of this specification. Tang Xiong (Hubei Provincial Measurement and Measurement Technology Institute) Wang Yanfeng (Hubei Provincial Measurement and Measurement Technology Research Institute) Li Shiliang (China Institute of Metrology) Participating drafters. Liu Haibo (Huangming Solar Energy Co., Ltd.) Zhang Xiaoli (China Quality Certification Center, Wuhan Branch) Xiaoyan Wu (Beijing Institute of Metrology and Detection) Ding Yumin (Shanghai Measurement and Measurement Technology Research Institute) table of ContentsIntroduction (II) 1 Scope (1) 2 References (1) 3 Terms and units of measure (1) 3.1 Unit Profiles Daylighting Area Useful Daily Heat (q17) (1) 3.2 Average Heat Loss Factor (USL) (1) 3.3 Domestic solar energy hot water system energy efficiency coefficient (CTP) (1) 3.4 Limitation of Energy Efficiency for Domestic Solar Hot Water Systems (2) 4 Overview (2) 5 Metrological requirements (2) 5.1 Energy Efficiency Labelling (2) 5.2 Energy Efficiency Indicators (2) 5.3 Energy efficiency rating (3) 6 Testing conditions (3) 6.1 Environmental Conditions (3) 6.2 Measuring Equipment (3) 6.3 Measurement uncertainty (5) 7 Testing Items and Methods (5) 7.1 Sampling Principles and Methods (5) 7.2 Sample Testing (6) 7.3 Original Records (13) 7.4 Data Processing (13) 8 Test Results (13) 8.1 Eligibility Criteria for Measurement of Energy Efficiency Index Measurements (13) 8.2 Test results assessment criteria (14) 8.3 Test Report (14) Appendix A Evaluation of the Uncertainty of Thermal Measurement Using a Unit with a Profile Sunlight Area for Domestic Solar Water Heating Systems Example(16) Appendix B Examples of Evaluation of Uncertainty in Measurement of Average Heat Loss Factor for Domestic Solar Hot Water Systems (21) Appendix C Examples of Evaluation of Uncertainty in Measurement of Energy Efficiency Coefficient (CTP) of Domestic Solar Hot Water Systems (24) Appendix D Sample Sheet for Energy Efficiency Measurement of Domestic Solar Hot Water Systems (format) (25) Appendix E Original records of energy efficiency measurement for domestic solar hot water systems (format) (26) Appendix F Energy Efficiency Measurement Test Report for Domestic Solar Hot Water Systems (Format) (30)IntroductionIn order to regulate the implementation of energy efficiency logo management of domestic solar hot water systems (hereinafter referred to as home solar energy) The energy efficiency measurement and inspection work is based on the JJF 1261.1-2017 Energy Efficiency Measurement and Detection Rules for Energy-using Products. Requirements, the development of this specification. This specification replaces JJF 1261.11-2013, compared with JJF 1261.11-2013, except for editorial modifications. The main changes are as follows. --- The name of the specification was changed from "Household solar hot water system energy efficiency identification measurement and measurement rules" to "Home use too Yangneng Hot Water System Energy Efficiency Measurement and Detection Rules; --- "5.1 energy efficiency labeling" to increase "energy efficiency information code" and "energy efficiency 'leader' information", etc. Claim; --- The original record format and test report format were revised accordingly (Appendix E, Appendix F). The previous versions of this specification were issued as follows. ---JJF 1261.11-2013. Domestic solar hot water system energy efficiency measurement and detection rules1 ScopeThis specification stipulates the energy efficiency measurement of domestic solar hot water systems with a hot storage tank volume of less than 0.6m3. Requirements, metrology and testing procedures, metrological testing methods, criteria for the assessment of measurement results, and test reports. This specification applies to energy efficiency measurement of domestic solar hot water systems with a capacity of up to 0.6m3 Supervisor inspection, commission inspection can refer to this specification. Units that produce and sell home solar hot water systems can also refer to This specification is tested. The tested domestic solar hot water system should be a product that the producers have passed their own inspection or imported by the seller. Sales of goods.2 referencesThis specification refers to the following documents. JJF 1261.1-2017 Energy Product Energy Efficiency Measurement Inspection Rules GB/T 2829-2002 Periodic Inspection Count Sampling Procedures and Tables (Applicable to Inspection of Process Stability) GB/T 12936 Solar Thermal Terms GB/T 18708 Domestic solar hot water system thermal performance test method GB/T 19141 Domestic Solar Hot Water System Technical Conditions GB 26969-2011 Domestic solar energy hot water system energy efficiency limit and energy efficiency grade GB/T 26970 home split dual loop solar hot water system technical conditions For dated references, only dated editions apply to this specification; for undated references, The latest version (including all amendments) applies to this specification.3 Terms and units of measureThe following terms and units of measurement apply to this specification. 3.1 Unit outline lighting area daily useful heat (q17) dailyusefulenergypercontouraperture Areaofdomesticsolarwaterheatingsystem When the water temperature in the hot water storage tank is not lower than the specified value under a certain amount of solar radiation, the unit outline lighting area is stored in the hot water tank The daily useful heat of water is measured in units of MJ/m2. 3.2 Average Heat Loss Factor (USL) averageheatlossfactorofdomesticsolarwaterheatingsys- Tem In the absence of solar irradiation, when the temperature difference between the temperature of the water stored in the domestic solar hot water system and the ambient temperature is 1K, the single The average heat loss of a domestic solar hot water system per unit of time, in units of W/(m3·K). 3.3 Domestic solar hot water system energy efficiency coefficient (CTP) thecoefficientofthermalperformanceof Domesticsolarwaterheatingsystem ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1261.11-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1261.11-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1261.11-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1261.11-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJF 1261.11-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1261.11-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |