JJF 1189-2008: Calibration Specification for Length Measuring Instrument
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1189-2008329 Add to Cart 3 days Calibration Specification for Length Measuring Instrument Valid

Similar standards

JJG 1114   JJF 1280   JJF 1126   JJG 1189.4   JJF 1367   JJG 1189.3   

Basic data

Standard ID: JJF 1189-2008 (JJF1189-2008)
Description (Translated English): Calibration Specification for Length Measuring Instrument
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A52
Classification of International Standard: 17.040
Word Count Estimation: 14,189
Date of Issue: 2008-03-24
Date of Implementation: 2008-06-24
Older Standard (superseded by this standard): JJG 55-1984
Quoted Standard: JJF 1001; JJF 1059; JJF 1094
Regulation (derived from): AQSIQ Announcement No. 35 of 2008
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard specifies the communication tunable laser source (hereinafter referred to as a tunable source) common metrological characteristics, calibration methods and equipment used in the calibration requirements, etc., for the first time tunable source calibration, calibration and use in subsequent tests. Other similar tunable source calibration can be implemented by reference. Tunable source type evaluation requirements relating to metrological characteristics, can refer to this specification.

JJF 1189-2008: Calibration Specification for Length Measuring Instrument

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Length Measuring Instrument People's Republic of China National Metrology Technical Specifications Length measuring instrument calibration specification Posted 2008-03-24 2008-06-24 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Length measuring instrument calibration specification LengthMeasuring Instrument Instead of JJG55-1984 This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on March 24, 2008, and from From June 24, 2008 into effect. Focal point. the National Technical Committee of length measuring geometry Main drafting unit. Jiangsu Province Institute of Metrology China Institute of Metrology This specification length measuring geometry commissioned the National Technical Committee is responsible for interpretation The main drafters of this specification. ROADS (Jiangsu Province Institute of Metrology) Goal Orientation (Jiangsu Province Institute of Metrology) Wang farming (China Institute of Metrology) Drafters participate. Hu Qing (Guiyang Xintian Optoelectronics Technology Co., Ltd.)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 flat cap and measured flatness vertical length measuring instrument fixed table (1) 4.2 Indication variability (1) 4.3 indication error (1) 4.4 measurement repeatability (1) 4.5 measured dimension indication error (1) 5 calibration conditions (1) 5.1 Environmental conditions (1) 5.2 Main standard equipment and ancillary equipment (1) Calibration Method 6 (2) 6.1 measurement plane caps, fixed table flatness (2) 6.2 Indication variability (3) 6.3 Indication error (3) 6.4 Measurement repeatability (4) 6.5 measured dimension indication error (4) 7 Calibration Results (4) 8 Recalibration interval (5) Appendix A Evaluation of Uncertainty in Measurement (Example) (6) Appendix B Typical length measuring instrument main technical parameters (8) Appendix C shows the range of values > is 1100mm auxiliary calibration method (9) Length measuring instrument calibration specification

1 Scope

This standard applies to the length measuring instrument calibration.

2 Citations

This specification references the following documents. JJF 1001-1998 common measurement terms and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 measuring instrument characteristics evaluation When using this specification the calibration should be noted that using the currently valid version of the documents cited.

3 Overview

Length measuring instrument is an optical mechanical or electromechanical combination of length measuring instruments, structure is divided into horizontal and vertical length measuring instrument Type length measuring instrument. Length measuring instrument by the base, seat and measuring measuring axis, tailstock, table, length of the standard device (scale or grating) and Readings or display device component. Length measuring instrument used to cover the entire range, continuous scale length of the standard device. Length measuring instrument measured by direct measurement or comparison of the measured gauge block, measuring tools, smooth gauge, thread gauge and fine Parts of machinery and length dimensions.

4 Metrological characteristics

4.1 Flatness measurement plane caps and vertical length measuring instrument fixed table 4.2 Indication variability 4.2.1 Indication variability measured using a flat cap when 4.2.2 Indication variability measurement using a spherical cap when 4.3 Indication error 4.4 Measurement repeatability 4.5 measured dimension indication error

5 calibration conditions

5.1 Environmental conditions Ambient temperature is generally controlled within (20 ± 3) ℃, or in accordance with the technical requirements of the relevant provisions. 5.2 Main standard equipment and ancillary equipment (see Table 1)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1189-2008_English be delivered?

Answer: Upon your order, we will start to translate JJF 1189-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1189-2008_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1189-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.