JJF 1150-2006 English PDFUS$449.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1150-2006: Calibration specification for relative spectral responsivity for photoelectric detectors Status: Valid
Basic dataStandard ID: JJF 1150-2006 (JJF1150-2006)Description (Translated English): Calibration specification for relative spectral responsivity for photoelectric detectors Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A60 Classification of International Standard: 17.180 Word Count Estimation: 17,117 Date of Issue: 2006-05-23 Date of Implementation: 2006-11-23 Older Standard (superseded by this standard): JJG 685-1990 Quoted Standard: GB/T 6495.8-2002; JJF 1001-1998 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to the photodetector, light meter probe luminance meter probes and other optical test equipment used by the photodetector relative spectral responsivity calibration. The wavelength range (300 ~ 2500) nm, other wavelengths may refer to the specification range of the calibration. JJF 1150-2006: Calibration specification for relative spectral responsivity for photoelectric detectors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Calibration specification for relative spectral responsivity for photoelectric detectors National Metrology Technical Specification of the People's Republic Photodetector relative spectral responsivity calibration specification Released on.2006-05-23 Implementation of.2006-11-23 The General Administration of Quality Supervision, Inspection and Quarantine issued Photodetector relative spectrum Responsive calibration specification Replace JJG685-1990 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on May 23,.2006, and Implemented on November 23,.2006. Focal Point. National Optical Metrology Technical Committee Main drafting unit. China Testing Technology Research Institute Participated in the drafting unit. China Institute of Metrology This specification is interpreted by the National Optical Metrology Technical Committee. The main drafters of this specification. Cao Yuansheng (China Testing Technology Research Institute) Participate in the drafters. Xiong Limin (China Institute of Metrology) table of Contents1 Scope (1) 2 Citations (1) 3 Terms and definitions (1) 4 Overview (1) 5 Measurement characteristics (1) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Calibration Equipment (2) 7 Calibration items (2) 7.1 Visual inspection (2) 7.2 Relative spectral responsivity of photodetectors (2) 8 Calibration method (2) 8.1 Visual inspection (2) 8.2 Photodetector relative spectral responsivity calibration (2) 9 Calibration result expression (4) 10 re-study interval (4) Appendix A Analysis of Uncertainty in Measurement of Relative Spectral Responsivity of Photodetectors (5) Appendix B Another Method for Calibration of Relative Spectral Responsivity of Photodetectors (8) Appendix C Photodetector Relative Spectral Responsive Calibration Record Format (10) Appendix D Calibration Certificate (Report) Content (11) Photodetector relative spectral responsivity calibration specification1 ScopeThis specification applies to light used in photodetectors, illuminometer probes, luminance meter probes, and other optical test instruments. Calibration of the relative spectral responsivity of the electrical detector. The wavelength range is (300~2500) nm, and other wavelength ranges can be used. Calibrate according to this specification.2 CitationsGB/T 6495.8-2002 "Photovoltaic devices - Part 8. Measurement of spectral response of photovoltaic devices" JJF 1001-1998 General Terms and Definitions Use of this specification should be done with the current valid version of the above cited documents.3 Terms and definitionsThe spectral responsivity R(λ) of a photodetector is defined as the output of the photodetector as a function of wavelength λ dY(λ) divided by the quotient of the photodetector monochromatic input dXe(λ)=Xe(λ)dλ in the wavelength interval dλ. R(λ)= dY(λ) dXe(λ) (1) The ratio of the spectral responsivity R(λ) of the photodetector at wavelength λ to the given reference value Sm. Rr(λ)= R(λ) Sm (2) Rr(λ) is the relative spectral responsivity of the detector. Sm can be the average, maximum or arbitrary of R(λ) Value.4 OverviewPhotodetector is a sensor that uses a material with photoelectric effect to convert an optical radiation signal into an electrical signal. Device. The photoelectric effect is divided into an internal photoelectric effect and an external photoelectric effect. Photodetectors fabricated by external photoelectric effect have photocells And photomultiplier tubes. Photodetectors fabricated using internal photoelectric effects are photoconductive and photovoltaic. Photoconductive detector Lead sulfide, mercury cadmium telluride, photoresistor, etc. Photovoltaic photodetectors are silicon photodiodes, silicon photocells, selenium optoelectronics Pool and so on. In general, whether it is a photodetector made by internal photoelectric effect or external photoelectric effect, their ringing It should only be in a certain spectral region and have strong spectral selectivity. That is, the spectral response of the photodetector Degrees are different at different wavelengths.5 Measurement characteristicsThe relative spectral responsivity of the photodetector operating wavelength range and calibration uncertainty are. Wavelength (300~400) nm. 2.6% (k=2.5); Wavelength (400~1100) nm. 1.7% (k=2.5); ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1150-2006_English be delivered?Answer: Upon your order, we will start to translate JJF 1150-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1150-2006_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1150-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |