JJF 1132-2005 English PDFUS$389.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1132-2005: Calibration Specification for Combined Type Angle Rules Status: Valid
Basic dataStandard ID: JJF 1132-2005 (JJF1132-2005)Description (Translated English): Calibration Specification for Combined Type Angle Rules Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A52 Classification of International Standard: 17.040 Word Count Estimation: 15,185 Date of Issue: 2005-04-28 Date of Implementation: 2005-07-28 Older Standard (superseded by this standard): JJG 132-1994 Quoted Standard: JJG 1; JJG 33; JJF 1059; JJF 1094 Summary: This standard applies: Not indexing plate measuring range 0�� ~ 180��, dividing the value is not 1��, ruler measuring range (0 ~ 300) mm, 1mm-scale value is not modular angle ruler calibrated. JJF 1132-2005: Calibration Specification for Combined Type Angle Rules---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Combined Type Angle Rules People's Republic of China National Measurement Specifications Combined angle scale calibration specification 2005-04-28 released 2005-07-28 implementation General Administration of Quality Supervision, Inspection and Quarantine released Combined angle scale calibration specification Instead of JJG132-1994 This standard was approved by the General Administration of Quality Supervision, Inspection and Quarantine on April 28,.2005 and has been July 28,.2005 shall come into force. Administrative Organization. National Geometrical Angle Measurement Technology Committee Drafting Organization. Changzhou Institute of Measurement and Testing Technology This specification is interpreted by the National Geometrical Angle Measurement Technical Committee Drafters of this Code. Jiang Xiaolan (Changzhou Institute of Measurement and Testing Technology) Yang Xiaonong (Changzhou Institute of Measurement and Testing Technology) Shen Yong (Changzhou Institute of Measurement and Testing Technology) table of Contents1 Scope (1) 2 References (1) 3 Overview (1) 4 Measurement Characteristics (1) 4.1 Flatness or straightness of each measuring surface (1) 4.2 ruler parallelism and indication error (2) 4.3 protractor indication error (2) 4.4 angular deviation of the angle (2) 4.5 ruler measuring line and the central gauge angle coincidence degree (2) 5 calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Calibration standards and the corresponding equipment (2) 6 Calibration Items and Calibration Methods (2) 6.1 The flatness or straightness of each measuring surface (2) 6.2 ruler parallelism and indication error (3) 6.3 protractor indication error (3) 6.4 Angles of the angle of the angle deviation (3) 6.5 ruler measuring line and center gauge bisector of coincidence (3) 7 Calibration Results Expression (4) 8 re-school interval (4) Appendix A special inspection cylinder technical requirements (5) Appendix B Combined Angle Gauge Measurement Results Uncertainty Analysis (6) Appendix C Calibration Certificate Internal Page Format (10) Combined angle scale calibration specification1 ScopeThis standard applies to the dial measuring range of 0 ° ~ 180 °, sub-degree value of 1 °, ruler measuring range (0 ~ 300) mm, dividing the value of 1mm modular angle scale calibration.2 ReferencesThis specification cites the following documents. JJG1-1999 steel ruler test procedures JJG33-2002 Universal angle foot test procedures General measurement terms and definitions Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 Measurement instrument characterization When using this specification, care should be taken to use the current valid version of the referenced offer.3 OverviewCombined angle gauge by the angle ruler, ruler, center gauge, scale seat, sub-dial and other components, the structure shown in Figure 1 Show. Including the base, sub-dial, ruler can form protractor. Figure 1 Schematic structure 1-center gauge; 2-foot holder; 3-indexing plate; 4-ruler; 5-angle foot; Combination angle gauge is mainly used for machining, wood processing angle, length, height measurement and centering Bit and so on.4 measurement characteristics4.1 flatness or straightness of each measuring surface The measuring surface does not allow convex, ruler measuring surface straightness is not greater than 0.02mm, other measuring surface flatness ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1132-2005_English be delivered?Answer: Upon your order, we will start to translate JJF 1132-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1132-2005_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1132-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |