JJF 1129-2005 English PDFUS$499.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1129-2005: Calibration specification of urine analyzers Status: Valid
Basic dataStandard ID: JJF 1129-2005 (JJF1129-2005)Description (Translated English): Calibration specification of urine analyzers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A61 Classification of International Standard: 17.180 Word Count Estimation: 19,192 Date of Issue: 2005-03-03 Date of Implementation: 2005-06-03 Issuing agency(ies): State Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to all types of urine analyzer calibration. JJF 1129-2005: Calibration specification of urine analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration specification of urine analyzers National Metrology Technical Specification of the People's Republic Urine Analyzer Calibration Specifications Released on.2005-03-03 2005-06-03 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Urine Analyzer Calibration Specifications ofUrineAnaly Zers This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 3,.2005, and It will take effect on June 3,.2005. Focal Point. National Physical and Chemical Metrology Technical Committee Main drafting unit. Hebei Institute of Metrology Participated in drafting unit. Hebei Bureau of Quality and Technical Supervision This specification entrusts the National Physical and Chemical Measurement Technical Committee to explain The main drafters of this specification. Ren Yanli (Hebei Institute of Metrology) Liu Zengming (Hebei Institute of Metrology) Liu Yan (Hebei Institute of Metrology) Participate in the drafters. Wang Shaoping (Hebei Institute of Metrology) Ban Li (Hebei Province Quality and Technical Supervision Bureau) Sun Lingxin (Hebei Institute of Metrology) table of Contents1 Scope (1) 2 Overview (1) 3 Metrological performance requirements (1) 3.1 blank (1) 3.2 indication (1) 4 General technical requirements (1) 4.1 Appearance (1) 4.2 Single measurement time (2) 4.3 Insulation resistance (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Standard solutions and other equipment (2) 6 Calibration items and calibration methods (3) 6.1 Visual inspection (3) 6.2 Preparation before calibration (3) 6.3 blank calibration (3) 6.4 Calibration of indication values (3) 6.5 Single measurement time (3) 6.6 Insulation resistance (3) 7 Expression of calibration results (3) 8 re-study interval (4) Appendix A Representation of various measurement results and gradient table (5) Appendix B Preparation of working standard solution (7) Appendix C Calibration Record Format (8) Appendix D Calibration Certificate Cover Format (9) Appendix E Calibration Instructions (10) Appendix F Calibration Certificate (Inside) Format (11) Urine Analyzer Calibration Specifications1 ScopeThis specification applies to the calibration of various types of urine analyzers.2 OverviewThe urine analyzer (hereinafter referred to as the instrument) is based on the measured components in the urine and the corresponding test blocks on the urine test strip. Independent reactions produce color changes for qualitative and quantitative measurement of urine composition. Test strip color block color change The depth is proportional to the corresponding components in the urine, so that the relative density (SG), pH, and whiteness of the urine are achieved. Cell (WBC or LEU), nitrite (NIT), protein (PRO), glucose (GLU), ketone body (KET), Urobilinogen (URO or UBG), bilirubin (BIL), red blood cells (RBC or BLD), and vitamin C (VC) Detection of the component. The instrument is mainly composed of photoelectric scanning system, mechanical system, motherboard, display system and attached test strips.3 Metrological performance requirements3.1 blank Should meet the requirements of Table 1. Table 1 Technical requirements for instrument blank Parameter SG pH WBC /( /μl) NIT /(μmol/l) PRO /(g/l) GLU /(mmol/l) KET /(mmol/l) URO /(μmol/l) BIL /(μmol/l) RBC /( /μl) VC /(mmol/l) measuring result 1.000~ 1.010 5.0~ 6.0 0 0 0 0 0 ≤3.4 0 0 0 Note. 1. The measurement results of the instrument (except SG, pH and VC) have two other representation methods, namely “-” and "neg", both of which are negative; or "normal", indicating normal. See Appendix A. 2. According to the instructions, individual instruments GLU ≤ 0.6mmol/l. 3.2 indication The measured values of the instrument shall comply with the requirements of Table 2.4 General technical requirements4.1 Appearance 4.1.1 The appearance of the instrument should be smooth and flat, and there should be no mechanical damage affecting the working performance; the surface of the display should be smooth and clean. No scratches, clear readings; good function of each device, regulator, switch and buttons. 4.1.2 Test strips used with the instrument should be neatly cut, no discoloration, no delamination, flat substrate, no falling block Like; during the warranty period. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1129-2005_English be delivered?Answer: Upon your order, we will start to translate JJF 1129-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1129-2005_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1129-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |