JG/T 356-2012 English PDFUS$759.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JG/T 356-2012: Test methods of building shading product on indoor environment thermal and visual comfort Status: Valid
Basic dataStandard ID: JG/T 356-2012 (JG/T356-2012)Description (Translated English): Test methods of building shading product on indoor environment thermal and visual comfort Sector / Industry: Building & Construction Industry Standard (Recommended) Classification of Chinese Standard: P04 Classification of International Standard: 91.010.30 Word Count Estimation: 29,297 Quoted Standard: JGJ/T 151-2008; JG/T 277-2010 Adopted Standard: DIN EN 14500-2008, NEQ Regulation (derived from): Ministry of Housing and Urban Notice No. 1234; industry standard filing Notice 2012 No. 4 (No. 148 overall) Issuing agency(ies): Ministry of Housing and Urban-Rural Development of the People's Republic of China Summary: This standard specifies the architectural shading thermal comfort and visual comfort performance testing methods terminology and symbols, thermal comfort, performance, visual comfort and performance test report. This standard applies except fluorescent ma JG/T 356-2012: Test methods of building shading product on indoor environment thermal and visual comfort---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Test methods of building shading product on indoor environment thermal and visual comfort ICS 91.010.30 P04 People's Republic of China building industry standards Building sunshading thermal comfort, visual comfort performance testing methods Posted on January 6,.2012 2012-05-01 implementation Ministry of Housing and Urban-Rural Development, People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and symbols 1 4 thermal comfort 3 5 visual comfort 9 6 test report 12 Appendix A (Normative) Dual Beam Spectrophotometer 13 Appendix B (Normative) Sunshade device direct sunlight - hemispherical transmittance and direct sunlight - hemispherical reflection ratio calculation method 16 Appendix C (informative) shade device and glass combination solar total transmittance calculation example 20 Appendix D (informative) optical parameters table 21 Appendix E (Normative) Opacity Tester 22 Appendix F (informative) thermal comfort and visual comfort performance rating 24 ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the redrafted law reference DINEN14500..2008 "sun blinds and shutters - thermal comfort and visual comfort - detection and Calculation Method, "which is not equivalent to DINEN14500..2008. This standard proposed by the Ministry of Housing and Urban Standard and Design Institute. This standard by the Ministry of Housing and Urban Construction Building Products and Components Products Standardization Technical Committee. This standard is drafted by. Beijing Zhongjian Institute of Building Research Co., Ltd., Fujian Institute of Building Science. Participated in the drafting of this standard. China Building Council (Group) Co., Ltd., Guangdong Provincial Academy of Building Research, Guangzhou Building Research Institute Institute, Tianjin Jianke Building Energy Conservation Environmental Monitoring Co., Ltd., Tianjin Construction Quality Testing Center, China Building Standard Design and Research Institute, Guangxi Building Research Institute, South China University of Technology School of Architecture, Guangzhou Institute of Building Materials Industry Co., Ltd., China Building Materials Materials Testing and Certification Center Co., Ltd., Shanghai Academy of Building Research (Group) Co., Ltd., China Academy of Building Research, Shenyang Purple microcomputer Electrical Equipment Co., Ltd., PerkinElmer Instruments Co., Ltd., Shimadzu International Trading (Shanghai) Co., Ltd., Beijing Construction Engineering Quality Sixth Detection of all the company. The main drafters of this standard. Duan Kai, Wang Yunxin, Wu Yuehua, Tu Fengxiang, Ma Yang, Ren Jing, Ren Jun, Du Jialin, Zhang Jinhua, Yu Xiaotong, Li Pan, Zhang Shujun, Zhu Huiying, Zhao Lihua, Xu Chuntao, Xue Gang, Yu Lu, Li Hua, Ye Jinting, Liu Yi, Zhang Hua, Liu Yue Li, Secretary crystal, Li Shengying, Li Jianbin, Liu Qiang, Wang Jining, Guo Yonghai, Fei Yijuan, Cui Xinyang, Wang Zhiyong, Bai Shengfang, Wang Guanying, Cui Ye-ting. Building sunshading thermal comfort, visual comfort performance testing methods1 ScopeThis standard specifies the construction of solar thermal comfort and visual comfort testing methods of terms and symbols, thermal comfort, visual comfort And test report. This standard applies to fluorescent materials and directional reflectance sunshade device, the parallel with the glass window construction sunshade thermal comfort and Visual comfort performance testing methods.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Thermal calculation procedures for building windows and doors glass curtain wall Building Sunshades Thermal comfort, visual comfort, performance and grading JG/T3 Terms and symbolsJG J/T 151-2008, JG/T 277-2010 defined and the following terms and symbols apply to this document. 3.1 Terms 3.1.1 Sun visor planeofsolarshading Shade products fully extended with the windows close to and parallel to the plane, sun blinds refers to the blade center axis of the plane. 3.1.2 Total solar transmittance totalsolarenergytransmittance Ratio of incoming solar radiation to incident solar radiation. 3.1.3 Shade shade shadingcoefficientofbuildingshadingproduct The total solar transmittance of a sunshade and a glazing (or standard window) combination is proportional to the total solar transmittance of the glazing (or standard window) The ratio of shading device is also known when outside the shade coefficient. 3.1.4 Glare conditioning performance glarecontrol By adjusting the sunshade device, changing the brightness, contrast or distribution range in the field of view, to reduce the visual discomfort, improve the observation details and Performance of the target ability. 3.1.5 Night privacy at night privacy When the sunshade device is fully extended and closed, it obstruct the external observation under normal lighting conditions to avoid the performance of being see-through by the outside world. Note. The normal lighting state is usually refers to the location of the human or object illumination value is not greater than 300lx. External observation refers to the outside observer from the shade device (stretch Show and close) 5m away from the indoor unit to identify the ability of the person or object 1m. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JG/T 356-2012_English be delivered?Answer: Upon your order, we will start to translate JG/T 356-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JG/T 356-2012_English with my colleagues?Answer: Yes. The purchased PDF of JG/T 356-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |