HYT187-2015 English PDFHYT187: Historical versions
Basic dataStandard ID: HY/T 187-2015 (HY/T187-2015)Description (Translated English): (Seawater circulating cooling system design specifications - Part 1: Intake technical requirements) Sector / Industry: Marine Industry Standard (Recommended) Classification of Chinese Standard: A45 Date of Issue: 2015-07-30 Date of Implementation: 2015-10-01 Regulation (derived from): ?State Oceanic Administration Announcement 2015 No.3 (Total No.24) Issuing agency(ies): State Oceanic Administration HYT187.1-2015: Code for design of recirculating cooling seawater system. Part 1: Requirement of intake technology---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Code for design of recirculating cooling seawater system.Part 1.Requirement of intake technology ICS 07.060;91.140 A45 People's Republic of China Marine Industry Standard Design specification for seawater circulating cooling system Part 1.Technical requirements for water extraction 2015-07-30 released 2015-10-01 Implementation Issued by the State Oceanic Administration ForewordHY/T 187 "Code for Design of Seawater Circulating Cooling System" is divided into 5 parts. ---Part 1.Technical requirements for water extraction; ---Part 2.Technical requirements for drainage; ---Part 3.Seawater pretreatment; ---Part 4.Circulating cooling system; ---Part 5.Material selection and anti-corrosion design guidelines. This part is part 1 of HY/T 187. This section was drafted in accordance with the rules given in GB/T 1.1-2009. This part was proposed by the Tianjin Seawater Desalination and Comprehensive Utilization Research Institute of the State Oceanic Administration. This part is under the jurisdiction of the National Marine Standardization Technical Committee (SAC/TC283). This section was drafted by. Tianjin Sea Water Desalination and Comprehensive Utilization Research Institute of State Oceanic Administration, Northeast China Municipal Engineering Design and Research Institute. The main drafters of this section. Wang Yinzhong, Fan Lihua, Wang Guoying, Zhang Lianqiang, Yin Jianhua, Zhang Yan, Chen Chong, Li Xue. Design specification for seawater circulating cooling system Part 1.Technical requirements for water extraction1 ScopeThis part of HY/T 187 specifies the technical requirements for the water intake engineering design of the seawater circulating cooling system. This part is applicable to the design of water intake engineering of seawater circulating cooling system for new construction, reconstruction and expansion, and the design of sea water intake engineering of other systems Can refer to implementation.2 Normative referencesThe following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 3097 Sea Water Quality Standard GB/T 16166 Sacrificial anode cathodic protection for seawater cooling water system of Binhai Power Plant GB 17378.4 Marine Monitoring Specification Part 4.Seawater Analysis GB 17501 Ocean Engineering Topographic Survey Specification GB/T 19570-2004 Technical Specification for Sewage Drainage Pipeline Engineering GB/T 23248-2009 Design code for seawater circulating cooling water treatment GB 50013-2006 Outdoor Water Supply Design Code GB 50050-2007 Design code for industrial circulating cooling water treatment GB 50265 Pumping Station Design Code GB 50268-2008 Code for construction and acceptance of water supply and drainage pipeline engineering GB 50296 Technical Specification for Water Supply Tube Well DL/T 5195 Code for design of hydraulic tunnel JTJ213-1998 Seaport Hydrological Code JTJ267 Port Engineering Concrete Structure Design Code JTJ275 Technical Specification for Corrosion Prevention of Concrete Structures in Seaport Engineering3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Seawater circulating cooling system recirculatingcoolingseawatersystem A water supply system that uses seawater as the cooling medium and circulates. It consists of heat exchange equipment, seawater cooling towers, water pumps, pipelines and other Close equipment composition. [GB/T 23248-2009, definition 3.1] 3.2 Unexpected environmental pollution incident on the sea It is unforeseeable to happen and cause sudden changes in the ecological environment elements of a local sea area. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HYT187-2015_English be delivered?Answer: Upon your order, we will start to translate HYT187-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of HYT187-2015_English with my colleagues?Answer: Yes. The purchased PDF of HYT187-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version HYT187-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version HYT187-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |