HJ 296: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
HJ 296-2021149 Add to Cart 3 days (Technical Requirements for Environmental Labeling Products Sanitary Ceramics) Valid
HJ/T 296-2006150 Add to Cart Auto, < 3 mins Technical requirement for environmental labeling products. Sanitary wares Obsolete

Similar standards

JG/T 311   JG/T 285   HJ 297   

Basic data

Standard ID: HJ 296-2021 (HJ296-2021)
Description (Translated English): (Technical Requirements for Environmental Labeling Products Sanitary Ceramics)
Sector / Industry: Environmental Protection Industry Standard
Classification of Chinese Standard: Q31
Word Count Estimation: 5,519
Issuing agency(ies): Ministry of Ecology and Environment
HJ/T 296-2006 HJ ENVIRONMENTAL PROTECTION INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing HBC 16-2003 Technical Requirement for Environmental Labeling Products – Sanitary Wares ISSUED ON: AUGUST 23, 2006 IMPLEMENTED ON: SEPTEMBER 01, 2006 Issued by: State Bureau of Environmental Protection

Table of Contents

Foreword ... 4 1 Scope ... 6 2 Normative References ... 6 3 Terms and Definitions ... 6 4 Basic Requirements ... 7 5 Technical Contents ... 8 6 Inspection Methods ... 8 Appendix A (Normative) Determination of Lead and Cadmium in Ceramic Samples ... 9

Foreword

In order to implement the Environmental Protection Law of the People's Republic of China; effectively use and save resources; reduce the impact of sanitary ceramics on the environment and human health in the production, use and disposal process; and guide and promote the production and use of environmentally friendly products; this Standard is formulated. This Standard stipulates the soluble lead and cadmium content limits of sanitary ceramics in accordance with the environmental standards in "Civil Engineering and Civil Building Materials" of South Korea. The radioactive specific activity index of sanitary ceramics is formulated based on the use of raw materials for sanitary ceramics in China. The principle of saving-water stipulates the maximum water consumption of the toilet; meanwhile, it stipulates the recycling rate of industrial waste generated during the production of sanitary ceramics. This Standard has partially modified the technical contents of Certifiable Technical Requirement for Environmental Labeling Products – Sanitary Ceramics (HBC 16- 2003). Compared with the Certifiable Technical Requirement for Environmental Labeling Products – Sanitary Ceramics (HBC 16-2003), the main changes of this Standard are as follows: --- Add the requirements for soluble lead and cadmium in sanitary ceramics, the requirements for the maximum water consumption of urinals and squatting pans, and the requirements for the recycling rate of industrial waste generated during the production of sanitary ceramics; --- Modify the radioactive specific activity index of sanitary ceramics; --- Delete the requirements for water absorption and crack resistance of sanitary ceramics. This Standard is a recommended standard, applicable to the certification of environmental labeling products in China. This Standard was proposed by the Department of Science & Technology, and Standards of the State Bureau of Environmental Protection. Chief drafting organizations of this Standard: Environmental Development Center of State Bureau of Environmental Protection; and National Research Center for Testing Techniques for Building Materials. This Standard was approved by the State Bureau of Environmental Protection on August 23, 2006. Technical Requirement for Environmental Labeling Products – Sanitary Wares

Scope

This Standard specifies the definition, basic requirements, technical content and inspection methods for the sanitary ceramics of environmental labeling products. This Standard is applicable to sanitary ceramic products such as washbasins, toilets, urinals, bidets, washing tanks, squatting pans, bathtubs, etc.

Normative References

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB 6566 Limits of Radionuclides in Building Materials GB 6952 Sanitary Wares GB/T 15555.2-1995 Solid Waste - Determination of Copper, Zinc, Lead, Cadmium - Atomic Absorption Spectrometry

Terms and Definitions

3.1 Internal exposure index The radioactive specific activity of the natural radionuclide radium-226 in sanitary ceramics is divided by the limit specified in this Standard. Expression formula: Where: IRa – internal exposure index;

Appendix A

(Normative) Determination of Lead and Cadmium in Ceramic Samples A.1 Principle The powder samples of ceramics were treated by strong acid; and the heavy metals of lead and cadmium in the solution were determined by flame atomic absorption spectrometry. A.2 Reagents --- Nitric acid (HNO3, ρ = 1.42 g/ml), guaranteed reagent; --- Preparation of nitric acid solution (1 + 1); --- Deionized water or distilled water. A.3 Apparatus --- Atomic absorption spectrophotometer; --- Filtering device: glass sand core filter, fiber filter membrane (pore size φ45μm); --- Adjustable electric heating plate. A.4 Sample preparation The sample is cleaned, dried, smashed, shrunk, ground to pass through an 80μm (180 mesh) sieve, and stored in a clean weighing bottle for later use. The preparation process shall avoid introducing impurities. A.5 Preparation of test solution Take 10 g of the sample (accurate to 0.0001 g) into a 100 ml beaker; add 25 ml of nitric acid solution; rinse the wall of the beaker with a small amount of distilled water; stir evenly; and cover with a watch glass. Place it on a 200°C low-temperature heating plate to heat for 2h; cool to stand for 1h; immediately filter into a 50 ml volumetric flask, rinse to the mark/ and shake well. This is the test solution of the sample to be tested. A.6 Blank test solution Use deionized water or distilled water to replace the sample; use the same procedures and reagents as the sample; and prepare a blank test solution while processing the
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of HJ 296-2021_English be delivered?

Answer: Upon your order, we will start to translate HJ 296-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of HJ 296-2021_English with my colleagues?

Answer: Yes. The purchased PDF of HJ 296-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version HJ 296-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version HJ 296-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.