Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

HJ 1066-2019 English PDF

US$1589.00 · In stock
Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email.
HJ 1066-2019: Technical specification for application and issuance of pollutant permit Printing industry
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
HJ 1066-20191589 Add to Cart 8 days Technical specification for application and issuance of pollutant permit Printing industry Valid

Similar standards

HJ 1060   HJ 1061   HJ 1059   

Basic data

Standard ID: HJ 1066-2019 (HJ1066-2019)
Description (Translated English): Technical specification for application and issuance of pollutant permit Printing industry
Sector / Industry: Environmental Protection Industry Standard
Word Count Estimation: 69,642
Date of Issue: 2019-12-10
Date of Implementation: 2019-12-10
Issuing agency(ies): Ministry of Ecology and Environment

HJ 1066-2019: Technical specification for application and issuance of pollutant permit Printing industry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Sewage Permit Application and Issuance Technical Specifications) National Standards of People's Republic of China Technical Specifications for Sewage Permit Application and Issuance Printing industry Technical specification for application and issuance of pollutant permit Printing industry 2019-12-10 Release 2019-12-10 Implementation Released by the Ministry of Ecology and Environment

Contents

Foreword ... ii 1 Scope ... 1 2 Normative references ... 1 3 Terms and definitions ... 2 4 Reporting requirements for basic information of sewage units ... 3 5 Corresponding discharge ports and methods for determining permitted discharge limits in the production and discharge sectors ... 15 6 Possible technical requirements for pollution prevention ... 16 7 Self-monitoring management requirements ... 19 8 Requirements for Compiling Environmental Management Ledger and Pollutant Emission Permit Report ... 22 9 Accounting method for actual emissions ... 26 10 Compliance Determination Method ... 26 Appendix A (Informative) Possible technical parameters for pollution prevention ... 29 Appendix B (Informative) Reference Table of Environmental Management Ledger Records (Key Management) ... 31 Appendix C (Informative) Reference Table of Environmental Management Ledger Records (Simplified Management) ... 38 Appendix D (Informative) Summary of Pollutant Permit Implementation ... 41 Appendix E (Informative) Form of Annual Implementation Report of Sewage Permit (Key Management) ... 44 Appendix F (Informative) Form of Annual Implementation Report of Sewage Permit (Simplified Management) ... 58 Appendix G (informative) Recommended method for calculating actual emissions ... 62

Foreword

In order to implement the "Environmental Protection Law of the People's Republic of China" Water Pollution Control Law, Soil Pollution Control Law of the People's Republic of China, and other laws and regulations; Notice on the Implementation Plan of the Emission Permit System (State Office of the People's Republic of China No..2016 ﹞ 81) "Administrative Measures for Emission Permits (Trial)" (Order of the Ministry of Environmental Protection No. 48) and "List of Classified Management of Pollutant Discharge Permits for Fixed Pollution Sources", improve the technical support system for pollution permits, and guide and regulate the printing industry The pollutant discharge unit shall apply for and issue a discharge permit to develop this standard. This standard specifies the basic requirements for the application and issuance of pollutant discharge permits for the printing industry's pollutant discharge units, the determination of permitted emission limits, Compliance determination methods and environmental management requirements such as self-monitoring, environmental management ledger, and pollution permit execution reports, proposed the printing industry Feasible technical requirements for pollution prevention. Appendices A to G of this standard are informative appendices. This standard is issued for the first time. This standard was formulated by the Department of Environmental Impact Assessment and Emission Management, and the Regulations and Standards Department of the Ministry of Ecology and Environment. The main drafters of this standard. East China University of Science and Technology, Shanghai Environmental Monitoring Center, Beijing Quanhua Environmental Technology Standards Research Center, China National Daily Chemical Industry Ink Branch. This standard was approved by the Ministry of Ecology and Environment on December 10,.2019. This standard will be implemented as of December 10,.2019. This standard is explained by the Ministry of Ecology and Environment. Sewage Permit Application and Issuance Technical Specifications Printing Industry

1 Scope

This standard specifies the basic requirements for the application and issuance of pollutant discharge permits for the printing industry's pollutant discharge units, the determination of permitted emission limits, Technical methods for compliance determination and environmental management requirements such as self-monitoring, environmental management ledger, and pollution permit execution report, proposed pollution Technical requirements for prevention and treatment. This standard is applicable to guide the printing industry sewage discharge unit to fill in the national sewage license management information platform (hereinafter referred to as the sewage license platform). Reporting relevant application information is applicable to guide the issuing authority to review and determine the permit requirements of the pollutant discharge unit of the pollutant discharge unit. This standard applies to the emission permit management of air pollutants and water pollutants discharged by the pollutant discharge units of the printing industry. Production facilities and discharge outlets that implement the “Boiler Air Pollutant Emission Standard” (GB 13271) in the pollutant discharge units of the printing industry are applicable In "Sewage Permit Application and Issuance of Technical Specifications for Boilers" (HJ 953). Printing industry sewage units that do not make provisions in this standard but discharge industrial waste water, waste gas or toxic and hazardous pollutants prescribed by the state Other pollution-producing facilities and discharge outlets are implemented in accordance with the General Rules for the Application of Pollutant Discharge Permits and Technical Specifications (HJ 942).

2 Normative references

The content of this standard refers to the following documents or the clauses therein. For undated references, the valid version is applicable to this standard. GB 8978 Integrated Wastewater Discharge Standard GB 13271 Boiler Air Pollutant Emission Standard GB 16297 comprehensive emission standards for air pollutants GB 37822 Volatile Organic Compounds Emission Control Standard GB/T 4754-2017 National Economic Industry Classification GB/T 16157 Determination of particulate matter and sampling methods of gaseous pollutants in exhaust gas from fixed pollution sources and amendments Classification and technical conditions of GB/T 16158 exhaust hood HJ 75 Technical Specifications for Continuous Monitoring of Flue Gas (SO2, NOX, Particulate Matter) Emissions from Stationary Pollution Sources HJ 493 Technical Requirements for Preservation and Management of Water Sampling Samples HJ 494 Water Quality Sampling Technical Guide HJ 495 Water Quality Sampling Scheme Design Technical Regulations HJ 608 Sewage unit coding rules HJ 732 Sampling air bag method for volatile organic compounds in fixed source exhaust gas HJ 819 Technical Guidelines for Self-monitoring of Sewage Units HJ 942 General Rules for Application and Issuance of Sewage Permits HJ 944 General Regulations on Technical Specifications for Environmental Management Ledgers and Pollutant Permits of Pollutant Discharge Units HJ 953 Application for Sewage Permit and Issuance of Technical Specifications HJ/T 55 Technical guidelines for fugitive emissions monitoring of air pollutants HJ/T 91 Technical specifications for surface water and sewage monitoring HJ/T 373 Technical Specifications for Monitoring Quality Assurance and Quality Control of Fixed Pollution Sources (Trial) HJ/T 397 Fixed source exhaust gas monitoring technical specifications AQ/T 4274 Technical Specifications for Detection and Evaluation of Controlled Wind Speed in Local Exhaust Facilities "Circular of the State Council on Printing and Distributing the Three-Year Action Plan to Win the Blue Sky Defense War" (Guo Fa [2018] No. 22) Catalogue of Classified Management of Pollutant Discharge Permits for Fixed Pollution Sources "Administrative Measures on Pollutant Discharge Permit (Trial)" (Decree No. 48 of the Ministry of Environmental Protection) "Technical Requirements for the Standardization of Sewage Outlets (Trial)" (SEPA Environmental Supervision [1996] No. 470) "Administrative Measures for the Operation of Automatic Monitoring Facilities for Pollution Sources" (Huanfa [2008] No. 6) Announcement on the Implementation of Special Emission Limits of Air Pollutants (Ministry of Environmental Protection Announcement.2013 No. 14) "Volatile Organic Compounds (VOCs) Pollution Control Technology Policy" (Announcement No. 31 of.2013 from the Ministry of Environmental Protection) "Reply Letter on Issues Concerning the Implementation of Special Emission Limits of Air Pollutants" (Environment Office Atmospheric Letter [2016] 1087)

3 terms and definitions

The following terms and definitions apply to this standard. 3.1 Printing Refers to the copying process of transferring a toner/colorant (such as ink) to a substrate using an analog or digital image carrier. 3.2 Printing industry Refers to production activities such as typesetting, plate making, coating before printing, varnishing, laminating, foiling, and mounting after printing. 3.3 Printing industry pollutant emission unit Refers to the sewage units engaged in the printing industry. 3.4 Printing ink Refers to the substance used to print on the substrate in the printing process, mainly composed of binder, pigment, solvent, auxiliary and so on. 3.5 Relief printing The graphic part of the finger print is higher than the non-graphic part. 3.6 Planographic printing The printing method of the graphic part and the non-graphic part of the finger printing plate is almost on the same plane. 3.7 Gravure printing The graphic part of the finger print is lower than the non-graphic part. 3.8 Permeographic printing A printing method in which the graphic area of the printing plate is leaking ink and the ink is not leaking in the non-graphic area. 3.9 Flexographic printing Refers to the printing method in which the ink is transferred to the surface of the substrate with an elastic relief printing plate. 3.10 Permitted emission limits Refers to the maximum discharge concentration (or rate) and amount of pollutants allowed by the pollutant discharge unit as specified in the pollutant discharge permit. 3.11 Special periods Refers to the pollution control unit ’s pollution control plan based on the environmental quality deadlines or other relevant environmental management documents formulated by the local people ’s government according to law. Periods with special requirements for the discharge of dyes, including the period of response to severely polluted weather and the period of winter defense. 3.12 Volatile organic compounds (VOCs) Refers to organic compounds that participate in atmospheric photochemical reactions, or organic compounds determined in accordance with relevant regulations. This standard uses non-methane total hydrocarbons (expressed as NMHC) as the comprehensive control index of volatile organic compounds emissions. To be related to the printing industry After the pollutant emission standards are issued and implemented, the regulations will follow.

4 Reporting requirements for basic information of sewage units

4.1 General principles The pollutant discharge unit shall fill in the corresponding information on the pollutant discharge permit platform in accordance with the requirements of this standard. Local ecological environment not included in the sewage permit platform If the competent authority in charge of the environment has a requirement to fill in the report or the polluting unit considers it necessary to fill in the report, it may add the content on its own. Local eco-environmental authorities at or above the city level with districts may increase the need to include And fill in the “Management Content Added by Local Eco-Environmental Authorities with Verification and Issuance Authority” in the sewage permit platform. 4.2 Basic information of pollutant discharge units The basic information of the pollutant discharge unit shall be filled in with the name of the unit, whether it needs to be corrected, the type of pollution permit management, postal code, industry category, Whether it is put into operation and the date of production, the latitude and longitude of the center of the production and operation site, and whether the location is an environmentally sensitive area (such as a key atmospheric control area, Total phosphorus and total nitrogen control area, etc.), whether it is located in the industrial park and the name of the industrial park to which it belongs, the environmental impact assessment approval document number (recording number), Local government identification or filing document number of the illegal project, document number of main pollutant total distribution plan, total particulate matter index (t/a), Total sulfur dioxide (t/a), total nitrogen oxides (t/a), total volatile organics (t/a), total chemical oxygen demand Indicator (t/a), total ammonia nitrogen indicator (t/a), total indicators of other pollutants involved, etc. When filling in the industry category, the pollutant discharge unit of the printing industry is selected according to the actual situation. "2311 Book and Newspaper Printing", "2312 Book Printing", "2319 Packaging and Decoration, and Printing and Printing (C23)" Other Printing "category. 4.3 Major Products and Capacity 4.3.1 General principles The pollutant discharge unit shall fill in the name of the main production unit, the name of the main process and the name of the production facility on the pollutant discharge permit platform according to the requirements of this standard Scale, production facility number, facility parameters, product name, production capacity, unit of measurement, design annual production time and other options. The following "4.3.2 ~ 4.3.6" are required and "4.3.7" are optional. 4.3.2 Main production units, main processes, production facilities and facility parameters The contents of the main production units, main processes and production facilities of key management pollutant discharge units are shown in Table 1. See Table 2 for the names of production units, main processes and production facilities. Table 1 List of the main production units, main processes and production facilities of the key management pollutant discharge units Main production unit main process production facility facility parameter unit Prepress processing Ink adjustment and ink supply system Ink pump power kW Mixer power kW Other other other Plate making Exposure machine power kW Imagesetter power kW Color proofing machine power kW Computer plate making machine power kW Plate making developing machine power kW Washing machine power kW Alcohol dampening machine power kW Dryer power kW Plate dryer power kW Punch machine power kW Other other other print Lithography Sheet-fed printing press capacity/h Production capacity of web printing machine Zhang/h Iron printing machine power kW Other other other Gravure printing Sheet-fed gravure printing press capacity/h Production capacity of web gravure printing machine m/min Unit gravure printing machine production capacity m/min Production capacity of satellite gravure printing machine m/min Other other other Letterpress (flexo) printing Production capacity of satellite flexographic printing press m/min Production capacity of multilayer flexographic printing machine m/min Unit Flexographic Printing Machine Production Capacity m/min Other other other Stencil printing Production capacity of flat screen printing machine m/min Production capacity of flat screen printing machine m/min Production capacity of circular screen printing machine m/min Production capacity of circular flat screen printing machine m/min Belt screen printing machine production capacity m/min Other other other other Oven power kW Production capacity of digital inkjet printer Zhang/h Other other other Other processing composite coating Production capacity of solvent-free laminating machine m/min Production capacity of dry compound machine m/min Production capacity of wet compound machine m/min Production capacity of pre-coated film laminating machine m/min Production capacity of coating film laminating machine m/min Coating machine coating width mm Coating machine production capacity m/min Calender production capacity m/min Automatic feed connection coating machine production capacity m/min Other other other Continued Main production unit main process production facility facility parameter unit Other processing other Gluing machine power kW Vacuum aluminizing machine power kW Power of automatic iron washing machine kW Paper machine power kW Adhesive mixer power kW Other other other Table 2 List of major production units, main processes and production facilities for simplified management of pollutant discharge units Main production unit main process production facility facility parameter unit Prepress processing Ink adjustment and ink supply system Ink pump power kW Mixer power kW Plate making Washing machine power kW Alcohol dampening machine power kW Dryer power kW Plate dryer power kW print Lithography Sheet-fed printing press capacity/h Production capacity of web printing machine Zhang/h Iron printing machine power kW Gravure printing Sheet-fed gravure printing press capacity/h Production capacity of web gravure printing machine m/min Unit gravure printing machine production capacity m/min Production capacity of satellite gravure printing machine m/min Letterpress (flexo) printing Production capacity of satellite flexographic printing press m/min Production capacity of multilayer flexographic printing machine m/min Unit Flexographic Printing Machine Production Capacity m/min Stencil printing Production capacity of flat screen printing machine m/min Production capacity of flat screen printing machine m/min Production capacity of circular screen printing machine m/min Production capacity of circular flat screen printing machine m/min Belt screen printing machine production capacity m/min other Oven power kW Production capacity of digital inkjet printer Zhang/h Other processing Composite coating Production capacity of solvent-free laminating machine m/min Production capacity of dry compound machine m/min Production capacity of wet compound machine m/min Production capacity of pre-coated film laminating machine m/min Production capacity of coating film laminating machine m/min Coating machine coating width mm Coating machine production capacity m/min Calender production capacity m/min Automatic feed connection coating machine production capacity m/min other Gluing machine power kW Power of automatic iron washing machine kW Paper machine power kW Adhesive mixer power kW 4.3.3 Production facility number The polluting unit shall report the internal production facility number. If the polluting unit does not have an internal production facility number, it shall be numbered and reported in accordance with HJ 608. 4.3.4 Product name Including composite packaging materials, trademarks, labels, boxes, wrapping paper, cartons, advertising, samples, calendars, plastic bags, composite Bags, wallpapers, building materials printing, paper, cardboard, textile printing, containers and porcelain, can printing, and others. 4.3.5 Production capacity and measurement unit The production capacity of the pollutant discharge unit is the designed production capacity of the main products, excluding the prod......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of HJ 1066-2019_English be delivered?

Answer: Upon your order, we will start to translate HJ 1066-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of HJ 1066-2019_English with my colleagues?

Answer: Yes. The purchased PDF of HJ 1066-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.