GBZ25841-2010 English PDFUS$599.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ25841-2010: Guide of protection relaying for 1000 kV power system Status: Obsolete
Basic dataStandard ID: GB/Z 25841-2010 (GB/Z25841-2010)Description (Translated English): Guide of protection relaying for 1000 kV power system Sector / Industry: National Standard Classification of Chinese Standard: F21 Classification of International Standard: 29.240.01 Word Count Estimation: 15,132 Date of Issue: 2010-12-23 Date of Implementation: 2011-05-01 Quoted Standard: GB/T 14285; GB/T 14598.9; GB/T 14598.10; GB/T 14598.13; GB/T 14598.14; GB/T 14598.16-2002; GB/T 14598.17-2005; GB/T 14598.18-2007; GB/T 15145; GB 16847; GB/T 17626.8; GB/T 17626.9; GB/T 19520.12; GB/T 20840.7; GB/T 20840.8; GB/T 22386; DL/T 364; DL/T 478; DL/T 587; DL/T 667; DL/T 670; DL/T 720; DL/T 770; DL 860; DL/T 866; IEC 60255-11-2008; IEC 60721-3-3; ITU-T 2MBIT/S G703 Regulation (derived from): ?National Standard Approval Announcement 2010 No.10 (Total No.165) Issuing agency(ies): Ministry of Health of the People's Republic of China Summary: This standard specifies the research 1 000 kV power system protection for, design, authorities to abide by the basic principles of construction and operation, etc., manufacturing, tests. The technical guidance document applies to 1 000 kV power system protection devices (referred to UHV protection). GBZ25841-2010: Guide of protection relaying for 1000 kV power system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Guide of protection relaying for 1000 kV power system ICS 29.240.01 F21 People's Republic of China national standardization of technical guidance documents Technical Guidelines for 1000 kV Power System Relay Protection Posted on.2010-12-23 2011-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 General requirements 2 4 line protection technical requirements 4 5 Transformer Protection Technical Requirements 6 6 bus protection 8 7 circuit breaker failure protection and reclosing 8 8 remote tripping and over-voltage protection 10 9 shunt reactor protection 10 Short lead protection ForewordThis guiding technical document is proposed and managed by China Electricity Council. The main drafting of this technical guidance document. State Grid Corporation, Nanjing NARI Electric Co., Ltd., China Southern Power Grid Dispatch Communication Center, Beijing Sifang Automation Co., Ltd., State Power Nanjing Automation Equipment Co., Ltd., Central China Power Dispatching and Communication Center, North China Power Dispatching and Communication Center, China Electric Power Research Institute. The main drafters of this technical guidance document, Zheng Yuping, Han Xiancai, Shu Zhihuai, Liu Huanzhang, Huang Shaofeng, Zhou Zexin, Wang Ning, Zhao Manyong, Huang Jian, Liu Hongtao. Technical Guidelines for 1000 kV Power System Relay Protection1 ScopeThis Guidance Document stipulates the scientific research, design, manufacture, testing, construction and operation of the 1000kV power system relay protection Relevant departments to comply with the basic guidelines. This guideline is applicable to the 1000kV power system relay protection device (referred to as UHV protection).2 Normative referencesThe following documents contain provisions which, through reference in this Guidance Document, become the provisions of this Guidance Note document. All dated Reference documents, all subsequent amendments (not including errata content), or revisions do not apply to this guidance document, however, drums Recipients of the agreement based on this guidance document are encouraged to study whether the latest versions of these documents are applicable. All undated references The latest version of this document applies to this guidance document. GB/T 14285 relay protection and safety automatic device technical regulations GB/T 14598.9 Electrical relays Part 22-3. Measuring relays and protection devices electrical disturbance test Radiated Electromagnetic Field interference test (GB/T 14598.9-2002, IEC 60255-22-3.2000, IDT) GB/T 14598.10 Electrical relays Part 22-4 - Electrical disturbance tests for measuring relays and protection devices Variable burst immunity test (GB/T 14598.10-2007, IEC 60255-22-4.2002, IDT) GB/T 14598.13 Electrical relays Part 22-1. Electrical disturbance tests for measuring relays and protection devices 1MHz pulse Rush immunity test (GB/T 14598.13-2008, IEC 60255-22-1.2007, MOD) GB/T 14598.14 Electrical disturbance tests for measuring relays and protection equipment - Part 2. Electrostatic discharge test (GB/T 14598.14-1998, idtIEC 60255-22-2.1996) GB/T 14598.16-2002 Electrical relays - Part 25. Electromagnetic emission test of measuring relays and protection devices (idtIEC 60255-25.2000) GB/T 14598.17-2005 Electrical relays - Part 22-6. Electrical disturbance tests for measuring relays and protection equipment - Radio frequency Field Induced Conducted Interference Immunity (IEC 60255-22-6.2001, IDT) GB/T 14598.18-2007 Electrical relays - Part 22-5. Electrical disturbance tests for measuring relays and protection devices - Surge Immunity test (IEC 60255-22-5.2002, IDT) GB/T 15145 transmission line protection devices for general technical conditions GB 16847 protection of current transformer transient characteristics of technical requirements (GB 16847-1997, idtIEC 60044-6.1992) GB/T 17626.8 Electromagnetic compatibility test and measurement techniques Frequency magnetic field immunity test (GB/T 17626.8-2006, IEC 61000-4-8.2001, IDT) GB/T 17626.9 Electromagnetic compatibility test and measurement techniques pulsed magnetic field immunity test (GB/T 17626.9-1998, idtIEC 61000-4-9.1993) GB/T 19520.12 electronic equipment mechanical structure 482.6mm (19in) series mechanical structure size 3-101 section. And its plug-ins Transformers - Part 7. Electronic voltage transformers (GB/T 20840.7-2007, IEC 60044-7). 1999, MOD) Transformers - Part 8. Electronic current transformers (GB/T 20840.8-2007, IEC 60044-8). 2002, MOD) GB/T 22386 power system transient data exchange common format (GB/T 22386-2008, IEC 60255-24.2001, IDT) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ25841-2010_English be delivered?Answer: Upon your order, we will start to translate GBZ25841-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZ25841-2010_English with my colleagues?Answer: Yes. The purchased PDF of GBZ25841-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |