GB/Z 25105.3-2010RFQ ASK 11 days Industrial communication networks -- Fieldbus specifications -- Type 10: PROFINET IO specifications -- Part 3: PROFINET IO communication profile Obsolete

Similar standards

GB/T 20438.5   GB/T 20438.4   GB/T 20438.3   GB/T 25105.2   GB/T 25105.1   GB/T 25105.3   

Basic data

Standard ID: GB/Z 25105.3-2010 (GB/Z25105.3-2010)
Description (Translated English): Industrial communication networks -- Fieldbus specifications -- Type 10: PROFINET IO specifications -- Part 3: PROFINET IO communication profile
Sector / Industry: National Standard
Classification of Chinese Standard: N10
Classification of International Standard: 25.040
Word Count Estimation: 65,620
Date of Issue: 2010-09-02
Date of Implementation: 2010-12-01
Quoted Standard: IEC 61010-1; IEC 61010-031; IEC 61010-2-010; IEC 61010-2-020; IEC 61010-2-030; IEC 61010-2-032; IEC 61010-2-040; IEC 61010-2 - 051; IEC 61010-2-061; IEC 61010-2-081; IEC 61010-2-101; GB/T 15629.2; GB/T 15629.3; GB/T 15629.11; GB/T 15929.2; GB/Z 25105.1-2010; GB/Z 25105.2-2010; IEC 61158-2; IEC 61158-3-1; IEC 61158-3-2; IEC 61158-3-3; IEC 61158-3-4; IEC 61158-3-7; IEC 61158 - 3-8; IEC 61158-3-11; IEC 61158-3-12; IEC 61158-3-13; IEC 61158-3-14; IEC 61158-3-16; IEC 61158-3-17; IEC 61158-3 -18; IEC 61158-3-19; IEC 61158-3-21; IEC 61158-3-22; IEC 61158-4-1; IEC 61158-4-2; IEC 61158-4-3; IEC 61158-4 - 4; IEC 61158-4-7; IEC 61158-4-8; IEC 61158-4-11; IEC 61158-4-12; IEC 61158-4-13; IEC 61158-4-14; IEC 61158-4-16; IEC 61158-4-17; IEC 61158-4-18; IEC 61158-4-19; IEC 61158-4-21; IEC 61158-4-22; IEC 61158
Adopted Standard: IEC 61784-2-2007, MOD
Regulation (derived from): ?National Standard Approval Announcement 2010 No.4 (Total No.159); PRC National Standard Approval Announcement 2014 No.22
Issuing agency(ies): Ministry of Health of the People's Republic of China
Summary: This standard provides: support for real-time performance Ethernet (RTE) needs classification, based on GB/T 15629. 3, IEC 61158 and IEC 61784-1 line regulation and related network components, capable of parallel and based on GB/T 15629. 3 Applications running RTE solution. These regulations are called the communication line real-time Ethernet (RTE) communication line regulation.

GBZ25105.3-2010: Industrial communication networks -- Fieldbus specifications -- Type 10: PROFINET IO specifications -- Part 3: PROFINET IO communication profile


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Industrial communication networks.Fieldbus specifications.Type 10. PROFINET IO specifications.Part 3. PROFINET IO communication profile ICS 25.040 N10 People's Republic of China national standardization of technical guidance documents Industrial Communication Network Fieldbus Specification Type 10.PROFINETIO specification Part 3. PROFINETIO Communications Profile Part 3.PROFINETIOcommunicationprofile (IEC 61784-2.2007, Industrial communication networkss- Profiles-Part 2.AdditionalFieldbusprofilesforreal-time networksbasedonISO /IEC 8802-3, MOD) 2010-09-02.2010-12-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ Introduction IV 1 Scope 1 2 Normative references 1 3 Terms, definitions, abbreviations, symbols and conventions 2 3.1 Terms and definitions 2 3.2 Abbreviations 5 3.3 symbol 6 3.4 Conventions 7 4 communication line regulation consistency 10 5 RTE performance index 10 5.1 The basic principles of performance indicators 10 5.2 Application Requirements 11 5.3 Performance Indicators 11 6 Conformance Testing 12 6.1 Concept 12 6.2 Method 13 6.3 Test Conditions and Test Cases 13 6.4 Test procedures and measurement 14 6.5 Test Report 14 7 Reserved 14 8 Communication Line Family 3 (PROFIBUS 8.1 Overview 14 8.2 Line Regulation CP3/4 20 Regulation 8.3 CP3/5 33 Line 8.4 CP3/6 41 Appendix A (Informative) Performance Calculation 50 References 59 Figure 1 consistency indicator graphical representation of Example 11 Figure 2 conformance test profile 13 Figure 3 Network Topology Example with CP3/4, CP3/5, and CP3/6 Components 20 Figure 4 has a wireless network segment network topology example 23 Figure 5 Calculation of transmission time and RTE throughput 29 Figure A.1 CP3/4. Example of a linear structure 50 Figure A.2 CP3/4. Example of a ring structure 51 Figure A.3 CP3/4. Examples of Wireless Network Segment 51 Figure A.4 CP3/4. Example of Integrated Wireless Client 52 Figure A.5 CP3/5. Examples of Linear Structures 52 Figure A.6 CP3/5. Example of a ring structure 53 Figure A.7 CP3/6. Examples of Linear Structures 54 Figure A.8 CP3/6. Example of a ring structure 55 Figure A.9 CP3/6. Examples of tree structure 56 Figure A.10 Definition of Bridging Delay 57 Figure A.11 Example of Switch Structure 58 Table 1 line (sub) bar selection table design 8 Table 2 (sub) bar selection table content 8 Table 3 Service Selection Table Design 8 Table 4 Service Selection Table Contents 8 Table 5 Parameter Selection Table Design 9 Table 6 Parameter Selection Table Contents 9 Table 7 class attribute selection table design 9 Table 8 Class Attribute Selection Table Contents 9 Table 9 Basic Network Topology Types 12 Table 10 Timeout values for name resolution 15 Table 11 IO Device Response Time 15 Table 12 Redundant classes for consistency classes 17 Table 13 Consistency class behavior 17 Table 14 Consistency of network components Class behavior 18 Table 15 CP3/4. AL Service Selection for IO Devices 21 Table 16 CP3/4. AL Protocol Selection for IO Devices and Network Components 24 Table 17 CP3/4. AL Protocol Selection for IO Controller 26 Table 18 CP3/4, CP3/5 and CP3/6. Overview of performance indicators 27 Table 19 CP3/4, CP3/5 and CP3/6. Performance Indicator Dependency Matrix 28 Table 20 Manager Parameters 30 Table 21 Client Parameters 31 Table 22 Redundancy Manager Parameter Sets 31 Table 23 CP3/4. PI Consistency Set 31 for MinDeviceInterval = 128ms Table 24 CP3/4. Hypotheses for pooled consistency set calculation Table 25 CP3/5. AL Service Selection for IO Devices 33 Table 26 CP3/5. AL Protocol Selection for IO Devices and Network Components 36 Table 27 CP3/5. AL Protocol Selection for IO Controller 38 Table 28 CP3/5. PI Consistency Set 40 for MinDeviceInterval = 128 ms Table 29 CP3/5. Assumptions for the calculation of the set of PI coherency 40 Table 30 CP3/6. AL Service Selection for IO Devices 41 Table 31 cache capabilities 43 Table 32 CP3/6. AL Protocol Selection for IO Devices and Network Components 44 Table 33 CP3/6. AL Protocol Selection for IO Controller 46 Table 34 CP3/6. PI Consistency Set 47 for MinDeviceInterval = 1ms Table 35 CP3/6. Assumptions for the calculation of PI-consistent sets 48

Foreword

GB /Z 25105-2010 "industrial communication network field bus specification type 10.PROFINETIO specification" is divided into the following three section. --- Part 1. Application layer service definition; --- Part 2. Application layer protocol specification; --- Part 3. PROFINETIO communication rules. This section GB /Z 25105-2010 Part 3. This part of the revision adopted IEC 61784-2.2007 (English version), the technical content of the original international standards no difference, for the convenience of our use Household use, the text of the structure of the layout of the appropriate adjustments, and press GB/T 1.1-2000 requirements for editing. Appendix A of this section is informative appendix. This part is proposed by China Machinery Industry Federation. This part of the National Industrial Process Measurement and Control Standardization Technical Committee (SAC/TC124) centralized. This part of the drafting unit. China Mechatronics Technology Applications Association, Machinery Industry Instrumentation Technology Institute of Economics, China Branch Institute of Shenyang Institute of Automation, Shanghai Automation Instrumentation Co., Ltd., Southwest University, Tsinghua University, Zhengzhou Institute of Light Industry Electrical Information Engineering College, Beijing Hollysys Systems Engineering Co., Ltd., Beijing China Control Technology Co., Ltd., Beijing Machinery Industry Automation Research The China Instrument Industry Association, Siemens (China) Co., Ltd., Phoenix Contact (Nanjing) R & D Engineering Technology Center Co., Ltd. The main drafters of this section. Li Baihuang, Wang Chunxi, Liu Dan, Wang Linkun, Liu Yunan, Yang Zhijia, Bao Weihua, Liu Feng, Wang Jinbiao, Tang Jiyang, Wang Yonghua, Luo An, Chen Xiaofeng, Dong Jingchen, Ouyang Jinsong, Huadun Yan, Zhang Dandan, Guo Jianfeng, Dou Lianwang, Zhang Long.

Introduction

This section provides communication for PROFINETTIO to existing PROFIBUS and PROFINET communication line families (CPFs) Line rules (CP). These regulations are in line with the industrial automation market goals, namely real-time Ethernet (Real-TimeEthernet, RTE) communication network and GB/T 15629.3 (commonly referred to as Ethernet) coexist. These RTE communication networks use the provisions of GB/T 15629.3 for the bottom of the communication stack Layer, in addition to providing more predictable, reliable real-time data transmission and support for accurate synchronization of automated equipment methods. In particular, these profiles help to correctly state the consistency of the RTE communication network with GB/T 15629.3 and help to avoid discrimination Diffusion of differences. Applying Ethernet technology to industrial communications between controllers, even for communication between controllers and field devices, drives Internet The use of mesh technology in the field area. If this availability results in the following features required by the industrial automation communication network in the field area Loss is unacceptable, these features include. ---real-time; --- Synchronous behavior between field devices (eg, drivers); --- Very small data record of effective, frequent exchange. These RTE profiles can take full advantage of Ethernet network improvements in transmission bandwidth and network range. Another implicit and important requirement is to completely preserve the typical communication capabilities of Ethernet (as used in office applications) so that Continue to use the software involved. For network solutions, the market needs several Conformity Classes (CCs), each of which has a variety of conformance requirements Performance characteristics and functional capabilities. RTE Performance Specifications (see Chapter 5) Enables Users to Associate Network Equipment with RTE Network Applications Matching, these performance indicators are based on the provisions of this standard communication RTE equipment provided. 5.1 defines the rationale for the performance specifications necessary to express the performance of a CP for a RTE. 5.2 Describe the application requirements Consideration. You can use an application-related class to find a suitable CP. Chapter 4 shows how to declare a device Consistency with CPF or CP. The CP in this section refers to the application layer (AL) protocol and service text. Industrial Communication Network Fieldbus Specification Type 10.PROFINETIO specification Part 3. PROFINETIO Communications Profile

1 Scope

GB /Z 25105 provisions of this section. --- Support for real-time Ethernet (RTE) demand classification performance indicators; --- Rules and related network components based on GB/T 15629.3, IEC 61158 and IEC 61784-1; --- RTE solution capable of running in parallel with GB/T 15629.3 based applications. These communication rules are known as real-time Ethernet (RTE) communication rules. Note. The RTE communication profile uses the GB/T 15629.3 communication network and its associated network components and supplements these standards for RTE characteristics.

2 Normative references

The following documents contain provisions which, through the reference in this part of GB /Z 25105, become the provisions of this section. Any reference to the date of the citation All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to be reached under this section The parties to the agreement examine whether the latest versions of these documents are available. For undated references, the latest version applies to this book section. GB/T 4793 (all parts) Safety requirements for electrical equipment for measurement, control and laboratory use (IEC 61010, IDT) GB/T 15629.2 Information technology - Telecommunications and information exchange between systems - LAN and MAN specific requirements Part 2 Logical Link Control (GB/T 15629.2-2008, ISO /IEC 8802-2.1998, IDT) GB/T 15629.3 Information Processing Systems - Local Area Networks - Part 3. Carrier Sense Multiple Access with Collision Detection (CSMA / CD) access methods and physical layer specification (GB/T 15629.3-1995, idtISO /IEC 8802-3.1990) GB/T 15629.11 Information technology - Telecommunications and information exchange between systems LAN and MAN specific requirements Article 11 Section. Wireless LAN Medium Access Control and Physical Layer Specification (GB/T 15629.11-2003, ISO /IEC 8802-11.1999, IDT) GB/T 15969.2 programmable logic controller Part 2. Equipment requirements and testing (GB/T 15969.2-2008, IEC 61131-2.2007, IDT) GB /Z 25105.1-2010 Industrial Communication Network Fieldbus specification type 10.PROFINETIO Code Part 1 Application layer service definition (IEC 61158-5-10.2007, MOD) GB /Z 25105.2-2010 Industrial Communication Network Fieldbus specification type 10.PROFINETIO norms Part 2 Points. Application layer protocol specification (IEC 61158-6-10.2007, MOD) IEC 61158 (All parts) Industrial Communication Network Fieldbus Specification IEC 61784-1 Code of practice for industrial communication networks Part 1. Fieldbus protocol IEC 61784-5-3 Industrial Communication Network Regulations Part 5-3. Fieldbus Installation CPF3 Communications Installation Routine ISO 15745-4/Amd1 industrial automation systems and integrated open systems application integration framework Part 4. For Ethernet-based Network Control System Reference Description Addition 1.PROFINET line regulation IEEE802.1AB Information Technology Inter-system Communication and Information Exchange LAN and Metro Websites and Media Access Control Connectivity Sexual discovery IEEE802.1D Information Technology Inter-system Communication and Information Exchange LAN and Metro MAC Bridge IEEE802.1Q Information Technology Systems for Communication and Information Exchange LANs and Metropolitan Area Networks Virtual LANs
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ25105.3-2010_English be delivered?

Answer: Upon your order, we will start to translate GBZ25105.3-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 7 ~ 11 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ25105.3-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ25105.3-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.