GB/T 6113.201-2018 PDF EnglishUS$1300.00 · In stock · Download in 9 seconds
GB/T 6113.201-2018: Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity -- Conducted disturbance measurements Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 6113.201: Historical versions
Similar standardsGB/T 6113.201-2018: Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity -- Conducted disturbance measurements---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT6113.201-2018 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 33.100 L 06 GB/T 6113.201-2018 / CISPR 16-2-1.2014 Replacing GB/T 6113.201-2017 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 2-1.Methods of Measurement of Disturbances and Immunity - Conducted Disturbance Measurements (CISPR 16-2-1.2014, IDT) Issued on. DECEMBER 28, 2018 Implemented on. JULY 1, 2019 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 4 1 Scope... 7 2 Normative References... 7 3 Terms, Definitions and Abbreviations... 8 3.1 Terms and Definitions... 8 3.2 Abbreviations... 14 4 Types of Disturbance to be Measured... 15 4.1 General... 15 4.2 Types of Disturbance... 15 4.3 Detector Functions... 15 5 Connection of Measuring Equipment... 16 5.1 General... 16 5.2 Connection of Ancillary Equipment... 16 5.3 Connections to RF Reference Ground... 16 5.4 Connection between the EUT and the Artificial Mains Network... 19 6 General Measurement Requirements and Conditions... 19 6.1 General... 19 6.2 Disturbance not Produced by the EUT... 19 6.3 Measurement of Continuous Disturbance... 20 6.4 EUT Arrangement and Measurement Conditions... 20 6.5 Interpretation of measuring results... 25 6.6 Measurement Times and Scan Rates for Continuous Disturbance... 26 7 Measurement of Disturbances Conducted Along Leads, 9 kHz to 30 MHz... 36 7.1 General... 36 7.2 Measuring Equipment (receivers, etc.)... 37 7.3 Ancillary measuring equipment... 37 7.4 EUT Configuration... 40 7.5 System Test Configuration for Conducted Emissions Measurements... 58 7.6 In Situ Measurements... 63 8 Automated Measurement of Disturbances... 65 8.1 Precautions for Automating Measurements... 65 8.2 Generic Measurement Procedure... 65 8.3 Prescan Measurements... 66 8.4 Data Reduction... 67 8.5 Disturbance Maximization and Final Measurement... 67 8.6 Post Processing and Reporting... 68 8.7 Disturbance Measurement Strategies with FFT-based Measuring Instruments... 68 9 Test Set-up and Measurement Procedure Using the CDNE in the Frequency Range 30 MHz to 300 MHz... 68 9.1 General... 68 9.2 Test Set-up... 69 9.3 Measurement Procedure... 71 Appendix A (informative) Guidelines for Connection of Electrical Equipment to the Artificial Mains Network... 73 Appendix B (informative) Use of Spectrum Analyzers and Scanning Receivers... 81 Appendix C (informative) Decision Tree for Use of Detectors for Conducted Disturbance Measurements... 84 Appendix D (informative) Scan Rates and Measurement Times for Use with the Average Detector... 86 Appendix E (informative) Guidelines for the Improvement of the Test Set-up with ANs ... 91 Appendix F (normative) Determination of Suitability of Spectrum Analyzers for Compliance Tests... 97 Appendix G (informative) Basic Guidance for Measurements on Telecommunications Ports... 98 Appendix H (normative) Specific Guidance for Conducted Disturbance Measurements on Telecommunication Ports... 106 Appendix I (informative) Examples of AANs and ANs for Screened Cables... 115 Bibliography... 125ForewordGB/T 6113 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods is a basic standard on electromagnetic compatibility. It is composed of the following four parts. Part 1.Radio Disturbance and Immunity Measuring Apparatus ---Part 1-1.Radio Disturbance and Immunity Measuring Apparatus - Measuring Equipment; ---Part 1-2.Radio Disturbance and Immunity Measuring Apparatus - Coupling Devices for Conducted Disturbance Measurements; ---Part 1-3.Radio Disturbance and Immunity Measuring Apparatus - Ancillary Equipment - Disturbances Power; ---Part 1-4.Radio Disturbance and Immunity Measuring Apparatus - Radiated Disturbance Measuring Antenna and Test Site; ---Part 1-5.Radio Disturbance and Immunity Measuring Apparatus - Antenna Calibration Sites and Reference Test Sites for 30 MHz ~ 1,000 MHz; ---Part 1-6.Radio Disturbance and Immunity Measuring Apparatus - EMC Antenna Calibration. Part 2.Methods of Measurement of Disturbances and Immunity ---Part 2-1.Methods of Measurement of Disturbances and Immunity - Conducted Disturbance Measurements; ---Part 2-2.Methods of Measurement of Disturbances and Immunity - Measurement of Disturbance Power; ---Part 2-3.Methods of Measurement of Disturbances and Immunity - Radiated Disturbance Measurements; ---Part 2-4.Methods of Measurement of Disturbances and Immunity - Immunity Measurements; ---Part 2-5.In Situ Measurements of Disturbing Emissions Produced by Physically Large Equipment. Part 3.CISPR Technical Reports ---Part 3.CISPR Technical Reports. Part 4.Uncertainties, Statistics and Limit Modeling ---Part 4-1.Uncertainties, Statistics and Limit Modeling - Uncertainties in Standardized EMC Tests; ---Part 4-2.Uncertainties, Statistics and Limit Modeling - Measurement Instrumentation Uncertainty; ---Part 4-3.Uncertainties, Statistics and Limit Modeling - Statistical Considerations in the Determination of EMC Compliance of Mass-produced Products; ---Part 4-4.Uncertainties, Statistics and Limit Modeling - Statistics of Complaints and a Model for the Calculation of Limits; ---Part 4-5.Uncertainties, Statistics and Limit Modeling - Conditions for the Use of Alternative Test Methods. This is Part 2-1 of GB/T 6113. This Part was drafted in accordance with the rules in GB/T 1.1-2009. This Part serves as a replacement of GB/T 6113.201-2017 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 2-1.Methods of Measurement of Disturbances and Immunity - Conducted Disturbance Measurements. In comparison with GB/T 6113.201-2017, the main technical changes are as follows. ---In accordance with the principle of equivalence, “NOTE” is added to the Scope to reflect the status of the EMC basic standard, and the relations between the product (category) standards of the relevant horizontal technical committees and the basic standard, and to consider necessary cooperation in the formulation of EMC standards; ---Four terms and definitions are added (see Chapter 3); ---Abbreviations are added (see 3.2); ---EUT arrangement is added (see 6.4.1); ---The working status of multi-function equipment is added (see 6.4.7); ---The determination of EUT arrangement that maximizes emissions is added (see 6.4.8); ---The recording of measurement results is added (see 6.4.9); ---The test set-up and measurement procedure using the CDNE in the frequency range 30 MHz ~ 300 MHz are added (see Chapter 9); ---The basic requirements for measurements on telecommunications ports are added (see Appendix G); ---The specific guidance for conducted disturbance measurements on telecommunication ports is added (see Appendix H); ---Examples of AANs and ANs used for screened cables are added (see Appendix I). This Part adopts the translation method in the equivalent adoption of CISPR 16-2-1.2014 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 2-1.Methods of Measurement of Disturbances and Immunity - Conducted Disturbance Measurements. The Chinese documents that have a consistent correspondence with the international documents normatively quoted in this Part are as follows. ---GB 4343.1-2018 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools and Similar Apparatus - Part 1.Emission (CISPR 14-1.2011, IDT); ---GB/T 4365-2003 Electro-technical Terminology - Electromagnetic Compatibility (IEC 60050 (161).1990, IDT); ---GB/T 6113.102-2008 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 1-2.Radio Disturbance and Immunity Measuring Apparatus - Ancillary Equipment - Conducted Disturbance (CISPR 16-1-2.2006, IDT); ---GB/T 6113.402-2018 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 4-2.Uncertainties, Statistics and Limit Modeling - Measurement Instrumentation Uncertainty (CISPR 16-4-2.2014, IDT). This Part was proposed by and shall be under the jurisdiction of National Technical Committee 79 on Radio Interference of Standardization Administration of China (SAC/TC 79). The drafting organizations of this Part. Shanghai Electrical Apparatus Research Institute; China Electronic Standardization Institute; Shanghai SANKI Electronics Industry Co., Ltd.; State Grid Electric Power Research Institute; Nanjing Rongce Testing Technology Co., Ltd.; China Shipbuilding Electromagnetic Compatibility Testing Center; Xiamen Products Quality Supervision & Inspection Institute; Shaanxi Hitech Electronic Co., Ltd.; Jiangsu Electronic Information Product Quality Supervision & Inspection Institute. The main drafters of this Part. Xing Lin, Cui Qiang, Shi Beina, Jiang Ninghao, Zhang Xia, Cheng Jianghe, Ren Ping, Guo Enquan, Zhao Dongjie, Wang Peng. The issuing of the previous versions. ---GB/T 6113.201-2008, GB/T 6113.201-2017. Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 2-1.Methods of Measurement of Disturbances and Immunity - Conducted Disturbance Measurements1 ScopeGB/T 6113 is designated a basic standard, which specifies the methods of measurement of disturbance phenomena in general in the frequency range 9 kHz to 18 GHz and especially of conducted disturbance phenomena in the frequency range 9 kHz to 30 MHz. With a CDNE, the frequency range is 9 kHz to 300 Hz.2 Normative ReferencesThe following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this Document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this Document. GB/T 6113.101-2016 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods of Measurement - Part 1-1.Radio Disturbance and Immunity Measuring Apparatus - Measuring Equipment (CISPR 16-1-1.2010, IDT)3 Terms, Definitions and Abbreviationsnetwork used to measure (or inject) asymmetric (common mode) voltages on unshielded symmetric signal (e.g. telecommunication) lines while rejecting the symmetric (differential mode) signal4 Types of Disturbance to be MeasuredDepending on the types of disturbance, measurements may be carried out using a measuring receiver with. Measuring receivers incorporating these detectors are specified in GB/T 6113.101-2016.5 Connection of Measuring EquipmentThe artificial network (AN) shall be connected to the reference ground by a low RF impedance, e.g. by direct bonding of the case of the AN to the reference ground of a shielded room, or with a low impedance conductor as short and as wide as practical (the maximum length to width ratio of which is 3.1, and the inductance of which is less than approximately 50 nH corresponding to an impedance of less than approximately 10 Ω at 30 MHz). An in situ test of the voltage division factor as explained in Appendix E is recommended.6 General Measurement Requirements and ConditionsThe measurement signal-to-noise ratio with respect to ambient noise shall meet the following requirements. Should the ambient noise level exceed the required level, it shall be recorded in the test report. The measuring receiver shall be kept tuned to the discrete frequency under investigation and retuned if the frequency fluctuates. Where not specified in the product standard, the EUT shall be configured as described in the following paragraphs.7 Measurement of Disturbances Conducted Along Leads, 9 kHz to 30 MHzThe common mode, differential and unsymmetric mode impedances of actual networks, such as of power mains and telecommunication networks, are location dependent and, in general, time varying.8 Automated Measurement of DisturbancesThe second step in the overall measurement procedure is used to reduce the number of signals collected during prescan and thus aimed at further reduction of the overall measurement time. These processes can accomplish different tasks, e.g. 9 Test Set-up and Measurement Procedure Using the CDNE in the Frequency Range 30 MHz to 300 MHz In general, the level of asymmetric voltage is higher than the level of unintentional symmetric voltage. Therefore, a minimum longitudinal conversion loss (LCL) value of 20 dB is adequate to prevent any influences of the symmetric voltage on the measurement results. The CDNE, with a defined minimum LCL of 20 dB, is not appropriate for EUTs with an intentional differential mode on the mains network. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 6113.201-2018 be delivered?Answer: The full copy PDF of English version of GB/T 6113.201-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 6113.201-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6113.201-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 6113.201-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 6113.201-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6113.201-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 6113.201-2018?A step-by-step guide to download PDF of GB/T 6113.201-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 6113.201-2018". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |