GB/T 5964-2008 English PDFUS$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5964-2008: Coaxial cable connectors used in nuclear instrumentation Status: Valid GB/T 5964: Historical versions
Basic dataStandard ID: GB/T 5964-2008 (GB/T5964-2008)Description (Translated English): Coaxial cable connectors used in nuclear instrumentation Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F81 Classification of International Standard: 27.120 Word Count Estimation: 11,118 Date of Issue: 2008-07-18 Date of Implementation: 2009-04-01 Older Standard (superseded by this standard): GB/T 5964-1986 Adopted Standard: IEC 60498-1975, NEQ; IEC 60313-2002, NEQ Regulation (derived from): Announcement of Newly Approved National Standards No. 12 of 2008 (No. 125 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies two types of high-voltage coaxial connector mating portion of the structure and size and major electrical properties. This standard applies to nuclear electronic instruments connected to high voltage coaxial connectors. Accordance with this standard structure and dimensions and technical requirements for manufacturing of products with similar foreign products in the mechanical and electrical properties can be achieved completely interchangeable. For signal transmission with a coaxial cable connectors, see Appendix A for the recommended three kinds of signal connector. GB/T 5964-2008: Coaxial cable connectors used in nuclear instrumentation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Coaxial cable connectors used in nuclear instrumentation ICS 27.120 F81 National Standards of People's Republic of China Replacing GB/T 5964-1986 Coaxial connectors used in nuclear instrumentation (IEC 60498. 1975, High-voltagecoaxialconnectorsusedinnuclear instrumentation, IEC 60313.2002, Coaxialconnectorsused innuclearlaboratoryinstrumentation, NEQ) Posted 2008-07-18 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis corresponds to the standard IEC 60498. 1975 "Nuclear instrumentation with high pressure coaxial connectors" and IEC 60313.2002 "Nuclear Laboratory instruments for Coaxial cable connector ", and IEC 60498. 1975 and IEC 60313.2002 non-equivalent. This standard replaces GB/T 5964-1986 "nuclear instrumentation with high pressure coaxial connectors." This standard and GB/T 5964-1986 The main differences are as follows. --- Standard name changed to "coax connectors used in nuclear instrumentation"; --- Increase IEC 60729 and other normative references; --- Increase the "Terms and Definitions", such as "peak voltage", "safe high-voltage connector (SHV)" and other terms; --- Increase in Appendix A "signal transmitted by a coaxial cable connector", whose contents are IEC 60313 recommended three coaxial signal transmission Cable connectors. Appendix A of this standard is a normative appendix. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee on nuclear instrumentation. This standard was drafted. nuclear (Beijing) Nuclear Instrument Factory, Institute of Nuclear Industry Standardization. The main drafters of this standard. Yan Guoli, Xiongzheng Long, Jiang Hongjun. This standard replaces the previous standard release case. GB/T 5964-1986. Coaxial connectors used in nuclear instrumentation1 ScopeThis standard specifies the high-voltage coaxial connector mating portion of the structure and size of the two types and the main electrical properties. This standard applies to high-voltage coaxial connectors and nuclear electronic instrument connected. According to the structure and size and technical requirements of this standard manufactured products with similar foreign products in the mechanical and electrical properties can be achieved complete exchange. About signal transmission coaxial connectors, see Appendix A recommended three signal connector.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 14865 SMB RF coaxial connectors (GB/T 14865-1993, idt IEC 60169-10. 1983) IEC 60169-8. 1978 RF connectors - Part 8. a bayonet locking, inside the insulator diameter of 6.5 mm (0.256 Inch) R. F. The coaxial cable connector characteristic impedance of 50 ohms (BNC type) (including Amendment 1.1996 and Amendment 2.1997) IEC 60729 CAMAC chassis multiple controllers3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Relative to baseline (OV) positive or negative voltage to the maximum value. 3.2 5kV voltage reaches the high-voltage connector. 3.3 Coaxial cable connection screw locking buckle ultra-miniature devices, also known as SMA connectors. 3.4 Connect coaxial cable ultra-miniature push the locking device, also known as SMB connectors.4 types and structure size4.1 Ⅰ-type high voltage coaxial connectors 4.1.1 plug structure and size, as shown in Table 1 and 1. 4.1.2 socket structure and dimensions, as shown in Table 2 and 2. Note. Ⅰ type high voltage coaxial connector is secure high-voltage connector, the peak voltage up to 5kV. 4.2 Ⅱ type high voltage coaxial connectors 4.2.1 plug structure and dimensions shown in Figure 3 and Table 3. 4.2.2 socket structure and dimensions, as shown in Table 4 and 4. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5964-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5964-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5964-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5964-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 5964-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5964-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |