GB/T 5202-2008 English PDFUS$554.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5202-2008: Radiation protection instrumentation -- Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors Status: Valid GB/T 5202: Historical versions
Basic dataStandard ID: GB/T 5202-2008 (GB/T5202-2008)Description (Translated English): Radiation protection instrumentation -- Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F84 Classification of International Standard: 13.280 Word Count Estimation: 28,276 Date of Issue: 2008-01-22 Date of Implementation: 2008-09-01 Older Standard (superseded by this standard): GB/T 5202-1985 Adopted Standard: IEC 60325-2002, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to the direct detection and direct measurement of emission �� and/or �� radionuclide surface contamination meters and monitors. GB/T 5202-2008: Radiation protection instrumentation -- Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Radiation protection instrumentation. Alpha, beta and alpha/beta (beta energy > 60 keV) contamination meters and monitors ICS 13.280 F84 National Standards of People's Republic of China GB/T 5202-2008/IEC 60325.2002 Replacing GB/T 5202-1985 Radiation protection instrumentation α, β, and Contamination meters and monitors (IEC 60325.2002, IDT) Posted 2008-09-01 2008-01-22 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Unit 4 5 Instruments Category 5 6 General characteristics 5 Detection means 5 6.1 6.2 5 easy decontamination 6.3 Seal 5 6.4 Alarm threshold 5 6.5 instrument indicated value 6 6.6 effective measurement range 6 6.7 Show 6 6 6.8 Mechanical Shock 6.9 Adjustment and maintenance of electronic equipment Annex 6 6 7 General test methods 7.1 Test 6 7.2 Overview 7 7.3 Bottom 7 7.4 statistical fluctuation 7 8 Electrical characteristics 8 8.1 statistical fluctuation 8 8.2 Response Time 8 8.3 Relationship between response time and statistical fluctuations between 9 8.4 9 drift alarm threshold 8.5 (portable instruments) Warm-up time test 9 8.6 10 time-resolved 10 8.7 Overload 8.8 Working Ping (only for detecting device) 11 8.9 threshold value (for detection devices only) 11 9 radiation characteristic 11 9.1 Overview 11 9.2 Efficiency 11 Instrument 9.3 Changes in response to the detector surface 12 9.4 Relative intrinsic error 12 9.5 surface emissivity changes in response with radiation energy 13 9.6 Responses to other ionizing radiation 14 GB/T 5202-2008/IEC 60325.2002 9.7 background count rate 15 10 Environmental Impact 15 Ambient temperature 10.1 15 10.2 Relative humidity 16 10.3 Power 16 10.4 Electromagnetic Compatibility 18 11 Storage 19 12 file 19 12.1 Certificate 19 Table 1 Reference conditions and standard test conditions 20 21 Table 2 Test performed under standard test conditions Table 3 Test changes affect the amount of 21 GB/T 5202-2008/IEC 60325.2002ForewordThis standard is identical with IEC 60325.2002 "Radiation protection instrumentation α, β and α/β (β energy > 60keV) contamination meters and monitoring Instrument "(in English). For ease of use, the standard of IEC 60325.2002 made the following editorial changes. --- Delete foreword international standards; --- "2 Normative references" by adopting international standards of international standard in place of the standard corresponding to GB/T 4960.6 Instead of IEC 60050 (393).1996 and IEC 60050 (394).1995, deleting the standard in the text does not appear; --- Deleting 10.3.1 and 10.3.1.1.1 regarding the AC does not meet the conditions of the content; --- According to Chinese customs for some formatting has been modified (for example. Note plus behind ".", followed by a series Item Description will be. "" To ";"; --- Use the decimal symbol instead of the international standard decimal symbol ",". ","; --- 6.8 has been specified since the content "mechanical impact", so deleting "11.2 mechanical impact," while deleting "11.1 Overview"; --- Table 3 "β radiation" a column "3.7MBq" and 9.6.3 paragraph 2 "370kBq" match instead 370kBq; --- Table 3 "warm-up time (portable instrument)" the last line of a column, "8.7.2" and the text does not match the standard (8.7.2 is the body of the Standard Test Method for overload protection) to "8.5.2"; --- Table 3 "Power" column in the frequency of "+ 1Hz -3Hz" to "47Hz 51Hz", and standard text 10.3.1.1.3 Representation agreement; --- Table 3 "radiation emission" column of the "1V/m" and 10.4.6.1 of "0.1V/m" does not match to 0.1V/m. This standard replaces GB/T 5202-1985 "α, β, and α-β surface contamination meters and monitors." The main changes compared to 5202-1985 standard and GB/T as follows. a) the standard name to "Radiation protection instrumentation α, β and α/β (β energy greater than 60keV) contamination meters and monitors"; b) increase the "instrument is classified" chapter; c) In the "environmental impact" chapter added "electromagnetic compatibility" content, including the "electrostatic discharge", "radio frequency electromagnetic fields," "by the pulse Group and conducted disturbances induced by radio frequency "," surge "," voltage sags and short interruptions "and" radiation emission requirements and test methods "drop. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee on nuclear instrumentation. This standard was drafted. Shenzhen Academy of Metrology and Quality Inspection, Xi'an Nuclear Instrument Factory Nuclear Group. The main drafters of this standard. name Lee Siu, Shen loyalty, Zhou Yingchun, Liangping. This standard was first released in July 1985. GB/T 5202-2008/IEC 60325.2002 Radiation protection instrumentation α, β, and Contamination meters and monitors1 ScopeThis standard applies to the direct measurement or detection of direct emission α and/or surface contamination meters and monitors β nuclides, which includes at least. --- Detecting means (including the counter, scintillation detector or a semiconductor detector, etc.), it can be fixed or connected by a flexible cable connection, or Who constitute a separate device; --- Measuring device. Some gauges and monitors the detection devices and measuring device composed in the detection and the instrument can separate case, alone With a detection device. To meet this standard, including all the requirements of detection devices and measuring devices instrument complies with the requirements of this standard, or detection device And measuring devices conform to the relevant part of the requirements of this standard. NOTE. For the latter use proven compliance with this standard, but can not infer portfolio allocation other special equipment is also standard. After a Ways it can use to allow users to use different combinations of factory production device configuration. This standard applies to. --- Α surface contamination measuring instrument; --- Α of surface contamination monitors; --- Β surface contamination meter; --- Β surface contamination monitors; --- Α/β surface contamination meter; --- Α/β surface contamination monitors. After two devices can simultaneously determine α and β contamination, and the measurement results are shown. --- Α (β, α/β) surface contamination measuring instrument. includes one or more radiation detectors and related devices or basic functional unit. Check in When the surface contamination, for measuring α (β, α/β) surface emissivity; --- Α (β, α/β) of surface contamination monitors. This standard also applies to those who have special-purpose equipment and special nature of the surface of the measurement instruments designed. But some of the required standard Need to be amended or supplemented in accordance with the special requirements of these instruments. If the instrument can achieve a variety of functions, the instrument must meet all of these requirements with different functions. If the instrument in a function Lord, both other functions, the instrument must meet all the requirements of the main functions, and as far as possible to meet the requirements of other functions. This standard does not apply to the measurement or detection of maximum energy less than the radiation monitor or meter 60keVβ particles. The purpose of this standard is to provide standards and give some examples of suitable methods, also provides general characteristics, general test conditions and parties Certificate, radiation characteristics, electrical safety, environmental characteristics, and α, β and α/β contamination meters and monitors.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 156-2007 standard voltage (IEC 60038.2002, MOD) GB/T 2423.5-1995 Environmental testing for electric and electronic products Part II. Test methods - Test Ea and guidance. Shock (Idt IEC 60068-2-27. 1987) GB/T 4960.6-1996 nuclear science and technology terminology nuclear instrumentation GB/T 5202-2008/IEC 60325.2002 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5202-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5202-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5202-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5202-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 5202-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5202-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |