GB/T 5124.5-2024 English PDFUS$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5124.5-2024: Methods for chemical analysis of hardmetals - Part 5: Determination of tantalum and niobium content - Inductively coupled plasma emission spectrometry Status: Valid
Basic dataStandard ID: GB/T 5124.5-2024 (GB/T5124.5-2024)Description (Translated English): Methods for chemical analysis of hardmetals - Part 5: Determination of tantalum and niobium content - Inductively coupled plasma emission spectrometry Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H16 Classification of International Standard: 77.160 Word Count Estimation: 11,140 Date of Issue: 2024-10-26 Date of Implementation: 2025-05-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 5124.5-2024: Methods for chemical analysis of hardmetals - Part 5: Determination of tantalum and niobium content - Inductively coupled plasma emission spectrometry---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT5124.5-2024 ICS 77.160 CCSH16 National Standard of the People's Republic of China Chemical analysis methods for cemented carbide Part 5.Determination of tantalum and niobium content Inductively Coupled Plasma Optical Emission Spectrometry Released on October 26, 2024 Implementation on May 1, 2025 State Administration for Market Regulation The National Standardization Administration issued PrefaceThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is Part 5 of GB/T 5124 Chemical analysis methods for cemented carbide. GB/T 5124 has been published in the following parts. --- Part 1.Determination of total carbon content - Gravimetric method; --- Part 2.Determination of insoluble (free) carbon content - Gravimetric method; --- Part 3.Determination of cobalt content - Potentiometric titration method; --- Part 4.Determination of titanium content - Hydrogen peroxide spectrophotometric method; --- Part 5.Determination of tantalum and niobium content - Inductively coupled plasma optical emission spectrometry. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by China Nonferrous Metals Industry Association. This document is under the jurisdiction of the National Technical Committee on Standardization of Nonferrous Metals (SAC/TC243). This document was drafted by. Zigong Cemented Carbide Co., Ltd., Zhuzhou Cemented Carbide Group Co., Ltd., Xiamen Tungsten Industry Co., Ltd. Shenzhen Zhongjin Lingnan Nonferrous Metals Co., Ltd., Xiamen Jinlu Special Alloy Co., Ltd., Hubei Green Tungsten Resource Recycling Co., Ltd., Luoyang Jinlu Cemented Carbide Tools Co., Ltd., National Standard (Beijing) Inspection and Certification Co., Ltd., Chengde Tianda Vanadium Industry Co., Ltd., Guangdong Province Industrial Analysis and Testing Center of the Chinese Academy of Sciences, Guangxi Zhuang Autonomous Region Analysis and Testing Research Center, and Hunan Aerospace Tianlu New Materials Testing Co., Ltd. The main drafters of this document are. Guan Yumei, Tan Qianyu, Xue Lin, Wang Pei, Zhu Ronghua, Xiang Peiyun, Peng Yu, Yan Xiaohua, Zhang Xiaodan, Yang Yuhui, Zuo Hongyi, Zhuo Yurui, Li Juan, Wang Ying, Yang Huizhen, Zhang Shubin, Feng Hao, Yang Yue, Hu Jicheng, Zhang Guofeng, Chen Xiaodong, Leng Shuo, Hu Mengqiao, Zhao Yan, Xie Xiaoxue, Wang Donghua, and Huang Yizhong.introductionCemented carbide has high hardness, strength, wear resistance and corrosion resistance, and is widely used in the manufacture of cutting tools, drilling tools, wear-resistant parts, etc. It is used in military industry, aerospace, mechanical processing, oil drilling, mining tools and other fields. Adding tantalum or niobium can increase the hardness and Wear resistance, therefore, cemented carbide with tantalum or niobium added is becoming more and more popular and its consumption is increasing. Therefore, it is necessary to establish an analytical standard for the chemical composition of tantalum and niobium in cemented carbide to improve the quality control and performance of the material. GB/T 5124 Chemical Analysis Methods for Cemented Carbide is to be published by It consists of five parts. --- Part 1.Gravimetric method for determination of total carbon content. The purpose is to establish a method for the determination of total carbon content. --- Part 2.Determination of insoluble (free) carbon content - Gravimetric method. The purpose is to establish a method for the determination of insoluble (free) carbon content. --- Part 3.Determination of cobalt content - Potentiometric titration method. The purpose is to establish a method for the determination of cobalt content. --- Part 4.Determination of titanium content - Hydrogen peroxide spectrophotometric method. The purpose is to establish a method for the determination of titanium content. --- Part 5.Determination of tantalum and niobium content - Inductively coupled plasma emission spectrometry. The purpose is to establish the determination of tantalum and niobium content. Determine the method. This document fully investigates domestic and foreign cemented carbide related product standards and the actual needs of cemented carbide analysis and testing in the industry, and expands the scope of cemented carbide The application field of the determination method of tantalum and niobium in cemented carbide has improved the versatility and standardization of the determination method of tantalum and niobium in cemented carbide industry. Standardization level, "Chemical analysis methods for cemented carbide Part 5.Determination of tantalum and niobium content - Inductively coupled plasma optical emission spectrometry" The formulation of this standard has positive guiding significance for improving the analysis method of cemented carbide components and improving the quality control capability of cemented carbide production. Chemical analysis methods for cemented carbide Part 5.Determination of tantalum and niobium content Inductively Coupled Plasma Optical Emission Spectrometry1 ScopeThis document specifies the method for the determination of tantalum and niobium content in cemented carbide by inductively coupled plasma optical emission spectrometry. This document is applicable to the determination of tantalum and niobium content in tungsten-based mixed powder and cemented carbide. Tantalum (Ta) content determination range. 0.050%~ 15.00%; Niobium (Nb) content (mass fraction) determination range. 0.050%~5.00%.2 Normative referencesThe contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 6682 Specifications and test methods for water used in analytical laboratories GB/T 8170 Rules for rounding off values and expression and determination of limit values GB/T 17433 Basic terminology for chemical analysis of metallurgical products3 Terms and DefinitionsThe terms and definitions defined in GB/T 17433 apply to this document.4 PrinciplesThe sample was dissolved in hydrofluoric acid-nitric acid, and the emission intensity of each element was measured on an inductively coupled plasma atomic emission spectrometer. The standard working curve was drawn by volume matching, and the mass fraction of each element was calculated according to the standard working curve method.5 Reagents and MaterialsUnless otherwise stated, only reagents of confirmed high-grade purity were used in the analyses. 5.1 Water, GB/T 6682, Grade 3. 5.2 High purity tungsten powder (wW≥99.99%). 5.3 Hydrofluoric acid (ρ = 1.14 g/mL). 5.4 Nitric acid (ρ=1.42 g/mL). 5.5 Standard stock solution. Use certified reference materials with a mass concentration of 1000 μg/mL for both tantalum and niobium. 5.6 Tantalum standard solution. Pipette 10 mL of the tantalum standard stock solution (5.5) into a 100 mL plastic volumetric flask, add 2 mL of nitric acid (5.4), 1 mL of hydrofluoric acid (5.3) is diluted to the mark with water and mixed. 1 mL of this solution contains 100 μg of tantalum. 5.7 Niobium standard solution. Pipette 10 mL of the niobium standard stock solution (5.5) into a 100 mL plastic volumetric flask, add 2 mL of nitric acid (5.4), ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5124.5-2024_English be delivered?Answer: Upon your order, we will start to translate GB/T 5124.5-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5124.5-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5124.5-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |