GB/T 50362-2022 English PDFGB/T 50362: Historical versions
Basic dataStandard ID: GB/T 50362-2022 (GB/T50362-2022)Description (Translated English): Technical standard for performance assessment of residential buildings Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: P30 Word Count Estimation: 151,124 Date of Issue: 2022-10-31 Date of Implementation: 2023-02-01 Issuing agency(ies): Ministry of Housing and Urban-Rural Development of the People's Republic of China; State Administration for Market Regulation GB/T 50362-2022: Technical standard for performance assessment of residential buildings---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.1 General 1.0.1 This standard is formulated to improve housing performance, promote the modernization of the housing industry, protect the rights and interests of consumers, and unify housing performance evaluation indicators and methods. 1.0.2 This standard is applicable to the performance review and identification of newly-built and rebuilt urban residences and concentrated rural residences. 1.0.3 Residences should be evaluated comprehensively from applicable performance, environmental performance, economic performance, safety performance and durability performance. Each performance shall be assigned a corresponding score according to its importance and content, and the housing performance shall be evaluated according to the score. 1.0.4 In addition to conforming to this standard, the housing performance evaluation should also comply with the current relevant national standards. 2 terms 2.0.1 Residential building applicable performance The performance suitable for users provided by the residential building itself and the configuration of internal equipment and facilities. 2.0.2 residential building environmental performance The performance of the outdoor environmental conditions of the residential area by artificial construction and natural formation. 2.0.3 residential building economic performance In the process of residential construction and use, the performance of energy saving, water saving, land saving and material saving. 2.0.4 residential building safety performance Residential buildings, structures, structures, equipment, facilities and materials do not endanger personal safety and are conducive to the performance of users avoiding disasters. 2.0.5 residential building durability performance Residential construction projects and equipment and facilities shall guarantee the performance of normal and safe use within a certain number of years. 2.0.6 Main dwelling types For residential buildings that account for the majority, the sum of the building areas of the sets shall not be less than 80% of the total building area of the dwellings. 3 Basic RegulationsEvaluation method. select each main house type for review (the sum of the construction area of each main house type is not less than 80% of the total building area of the house) and check one set of each house type. 4.2.3 Modulus coordination and remodelability (8 points) should include. residential plane modular design, flexible space separation and remodelability, and structural system flexibility. Evaluation method. select the standard layer of each unit for inspection. 4.2.4 The evaluation content of unit public space (17 points) should include. unit entrance hall (entry hall), lobby, waiting hall setting, building (electric) elevator setting, unit public walkway, garbage collection facilities and tube well setting. Evaluation method. Select each unit for inspection. 4.3 Set type 4.3.1 The evaluation of the suite type should include the setting and layout of the functional space in the suite, and 2 sub-items of 5 dimensions of the functional space, with a full score of 72 points. Score according to the evaluation indicators in Table D.0.2 in Appendix D of this standard. 4.3.2 The evaluation content of functional space setting and layout in a suite (44 points) shall include. configuration, layout and traffic organization of functional spaces such as bedroom, living room (hall), dining room, kitchen, bathroom, storage room, balcony, etc., the natural ventilation, lighting and view of the living space, the location of the kitchen and its natural ventilation and lighting. Evaluation method. select each main house type for review (the sum of the construction area of each main house type is not less than 80% of the total building area of the house) and check one set of each house type. 4.3.3 The evaluation content of functional space scale (28 points) should include. configuration of functional space area, length of continuous solid wall in living room (hall), clear width of double bedroom, length of operating table in kitchen, use of storage space Area, net height of functional space. Evaluation method. select each main house type for review (the sum of the construction area of each main house type is not less than 80% of the total building area of the house) and check one set of each house type. 4.4 Decoration 4.4.1 The evaluation of decoration shall include two sub-items of interior decoration and public part decoration, with a full score of 25 points. Score according to the evaluation indicators in Table D.0.3 in Appendix D of this standard. Evaluation method. Among all the housing types, 5 housing units are randomly selected on site for inspection. 4.5 Sound insulation performance 4.5.1 The evaluation of sound insulation performance shall include 4 sub-items of sound insulation performance of floors, sound insulation performance of walls, noise volume of pipes, vibration reduction and sound insulation of equipment, with a full score of 25 points. Score according to the evaluation indicators in Table D.0.4 in Appendix D of this standard. Evaluation method. Select and review construction drawings and performance test reports. 4.6 Equipment and facilities 4.6.1 The evaluation of equipment and facilities shall include 4 sub-items of kitchen and bathroom equipment, water supply and drainage and gas system, heating ventilation and air conditioning system, electrical equipment and facilities, and the full score is 70 points. Score according to the evaluation indicators in Table D.0.5 in Appendix D of this standard. 4.6.2 The evaluation content of kitchen and bathroom equipment (18 points) should include. kitchen facilities configuration, overall kitchen configuration, sanitary facilities configuration, overall bathroom configuration, washing machine, housework room and clothes drying space. Evaluation method. select each main house type for review (the sum of the construction area of each main house type is not less than 80% of the total building area of the house) and check one set of each house type. 4.6.3 The evaluation content of water supply, drainage and gas system (18 points) shall include. the setting of water supply, drainage and gas facilities, the setting of hot water supply system or water heater and hot water pipeline, the setting of special drinking water system, and the setting of drainage system, piping and piping arrangements. Evaluation method. select a residential building of the same type, and check a set of residential buildings randomly. 4.6.4 The evaluation content of heating, ventilation and air conditioning system (16 points) should include. heating, ventilation, and air conditioning system and facilities of living space, fresh air system, kitchen oil fume exhaust system, bathroom exhaust system. Evaluation method. select each main housing type for review (the sum of the construction area of each main housing type is not less than 80% of the total residential building area, and each housing type is selected for random inspection. 4.6.5 The evaluation content of electrical equipment and facilities (18 points) should include. the number of power sockets, the number of branch circuits, the setting of elevators, and the artificial lighting of public parts in the building. Evaluation method. select each main house type for review (the sum of the construction area of each main house type is not less than 80% of the total building area of the house) and check one set of each house type. 4.7 Indoor barrier-free facilities and aging 4.7.1 The assessment of indoor barrier-free facilities and age-appropriateness shall include two sub-items. barrier-free facilities and age-appropriateness in suites, and barrier-free facilities in public areas, with a full score of 15 points. Score according to the evaluation indicators in Table D.0.6 in Appendix D of this standard. 4.7.2 The evaluation content of barrier-free facilities and aging suitability (9 points) in the suite should include. the ground height difference in the suite, the opening of the inner door leaf in the suite and the clear width of the aisle in the suite, the distance between the bathroom sanitary ware and the surrounding walls, the distance between the bathing space scale. Evaluation method. Select and review design drawings, design instructions and on-site inspection. 4.7.3 The evaluation content of barrier-free facilities in public areas (6 points) should include. elevator installation, clear width of the corridor from the waiting hall to the entrance hall, and public entrances and exits. Evaluation method. Select and review design drawings, design instructions and on-site inspection.5 Environmental performance5.1 General provisions 5.1.1 The evaluation of environmental performance shall include 7 evaluation items including land use and planning, architectural modeling, green space and activity venues, outdoor noise and air pollution, water body and drainage system, supporting facilities and intelligent system, with a full score of 250 points. 5.1.2 The evaluation indicators of residential environmental performance shall comply with the provisions of Appendix E of this standard. 5.2 Land Use and Planning 5.2.1 The evaluation of land use and planning shall include 4 sub-items of land use, spatial layout, road traffic, and municipal facilities, with a full score of 68 points. Score according to the evaluation indicators in Table E.0.1 in Appendix E of this standard. 5.2.2 The evaluation content of land use (12 points) should include. utilization of original terrain, protection and utilization of natural environment and resources, and control of various types of pollution. Evaluation method. Select and review the approval documents and on-site inspections of local governments related to land use and planning schemes. 5.2.3 Spatial layout (18 points) The evaluation content should include. residential area land use balance, residential area planning classification, building density, space level, courtyard space. Evaluation method. Select and review the relevant land use requirements of the local government, residential area planning and design documents and on-site inspection. 5.2.4 The evaluation content of road traffic (32 points) should include. entrance and exit selection, road system structure, road pavement, motor vehicle parking, non-motor vehicle parking, sign system, urban traffic around residential areas. Evaluation method. review planning and design documents and on-site inspection. 5.2.5 The evaluation content of municipal facilities (6 points) should include. municipal infrastructure. Evaluation method. Selection and review of documents and on-site inspections of municipal facilities. 5.3 Architectural modeling 5.3.1 The evaluation of architectural modeling shall include 3 sub-items of modeling and facade, color effect, and outdoor lighting, with a full score of 15 points. Score according to the evaluation indicators in Table E.0.2 in Appendix E of this standard. 5.3.2 The evaluation content of shape and facade (10 points) should include. architectural form and facade. Evaluation method. select and review relevant design documents and on-site inspection. 5.3.3 The evaluation content of color effect (2 points) should include. coordination between architectural color and environment. Evaluation method. select and review relevant design documents and on-site inspection. 5.3.4 The evaluation content of outdoor lighting (3 points) should include. night lighting modeling, urban night scene requirements, and glare interference. Evaluation method. select and review relevant design documents and on-site inspection. 5.4 Green spaces and activity venues 5.4.1 The evaluation of green spaces and activity venues shall include four sub-items. green space configuration, plant abundance and greening, outdoor activity venues, and barrier-free facilities, with a full score of 53 points. Score according to the evaluation indicators in Table E.0.3 in Appendix E of this standard. 5.4.2 Green space configuration (15 points) evaluation content should include. green space configuration, green space rate, per capita park green area, per capita green area, green utilization of corners, parking spaces, walls, platforms, roofs and balconies, etc., green space and rainwater regulation and storage. Evaluation method. Select and review the general layout design drawings, review the landscape and greening design documents and on-site inspection. 5.4.3 The evaluation content of plant abundance and green planting (14 points) should include. plant selection and configuration, plant abundance, greening and landscape, plant ornamental and seasonal phase, number of trees, shading requirements, and plant growth. Evaluation method. Select and review landscape and greening design documents and on-site inspection. 5.4.4 The evaluation content of outdoor activity venues (14 points) should include. hard pavement, shading measures for leisure venues, lighting for activity venues, venue configuration, slope of activity venues, and setting of emergency shelters. Evaluation method. Select and review landscape and greening design documents and on-site inspection. 5.4.5 The evaluation content of barrier-free facilities (10 points) should include. roads in residential areas, entrances and exits of public green spaces, anti-skid sites, public toilets, public service facilities in residential areas, and barrier-free parking. Evaluation method. Select and review planning and design drawings, review landscape and greening design documents and on-site inspection. 5.5 Outdoor Noise and Air Pollution 5.5.1 The assessment of outdoor noise and air pollution shall include two sub-items of outdoor noise and air pollution, with a full score of 16 points. Score according to the evaluation indicators in Table E.0.4 in Appendix E of this standard. 5.5.2 The evaluation content of outdoor noise (8 points) should include. equivalent sound level of outdoor noise, equivalent sound level of outdoor accidental noise at night. Evaluation method. select and review the outdoor noise detection report and on-site inspection. 5.5.3 The evaluation content of air pollution (8 points) should include. emission local pollution sources, open local pollution sources, spillover local pollution sources, and dust. Assessment method. select and review air pollution test reports and on-site inspections. 5.6 Water bodies and drainage systems 5.6.1 The assessment of water body and drainage system shall include two sub-items of water body and drainage system, with a full score of 10 points. Score according to the evaluation indicators in Table E.0.5 in Appendix E of this standard. 5.6.2 The evaluation content of water body (6 points) should include. water quality of natural water body and man-made landscape water body, swimming pool water quality. Evaluation method. Select and review water quality test reports and on-site inspections. 5.6.3 The evaluation content of the drainage system (4 points) should include. rain and sewage diversion drainage system. Evaluation method. Select and review the design documents of the rainwater drainage system and on-site inspection. 5.7 Supporting facilities 5.7.1 The evaluation of supporting facilities shall include two sub-items of community service facilities and environmental sanitation, with a full score of 58 points. Score according to the evaluation indicators in Table E.0.6 in Appendix E of this standard. 5.7.2 The evaluation content of community service facilities (41 points) should include. community service facilities. Evaluation method. select and review planning and design documents and on-site inspection. 5.7.3 Environmental sanitation (17 points) should include. waste bin configuration, waste sorting and transportation, waste storage and treatment. Evaluation method. select and review planning and design documents and on-site inspection. 5.8 Intelligent system 5.8.1 The evaluation of the intelligent system shall include three sub-items of management center and project quality, system configuration, and operation management, with a full score of 30 points. Score according to the evaluation indicators in Table E.0.7 in Appendix E of this standard. 5.8.2 The evaluation content of management center and engineering quality (8 points) should include. management center, pipeline engineering, installation quality, power supply and lightning protection grounding. Evaluation method. Select and review the intelligent system design documents and on-site inspection. 5.8.3 The evaluation content of system configuration (18 points) should include. security subsystem, management and monitoring subsystem, information network subsystem. Evaluation method. Select and review the intelligent system design documents and on-site inspection. 5.8.4 The evaluation content of operation management (4 points) should include. the configuration of operation management services. Evaluation method. Select and review relevant documents and on-site inspections of operation management.6 Economic performance6.1 General provisions 6.1.1 The evaluation of economic performance shall include 4 evaluation items of energy saving, water saving, land saving and material saving, with a full score of.200 points. 6.1.2 The evaluation indicators of economic performance shall comply with the provisions of Appendix F of this standard. 6.2 Energy saving 6.2.1 The evaluation of energy saving shall include four sub-items of building and enclosure structure, heating and air-conditioning system, lighting and electrical, and renewable energy utilization, with a full score of 100 points. Score according to the evaluation indicators in Table F.0.1 in Appendix F of this standard. 6.2.2 The evaluation content of building and enclosure structure (60 points) should include. building orientation, building shape coefficient, window-to-wall area ratio, external window shading, oriel window, heat transfer coefficient of external wall, external window and roof. Evaluation method. Review design materials (including architectural design drawings, construction drawings and energy-saving calculations) and on-site inspection. 6.2.3 The evaluation content of heating and air conditioning system (20 points) should include. dynamic hydraulic balance measures of heating and air conditioning system, energy saving measures under partial load, air conditioning location, selection of air conditioning equipment, room temperature control, and location of outdoor unit. Evaluation method. review design drawings and relevant technical documents. 6.2.4 The evaluation content of lighting and electrical system (10 points) should include. energy-saving measures for lighting in public areas, energy-saving measures for elevators, and selection of energy-saving electrical equipment. Evaluation method. review design drawings and relevant technical documents. 6.2.5 The evaluation content of renewable energy utilization (10 points) should include. the proportion of the use of renewable energy to provide domestic hot water or heating and air conditioning or power generation to the total residential electricity consumption. Evaluation method. review design drawings and relevant technical documents. 6.3 Water saving 6.3.1 The evaluation of water saving shall include three sub-items of water saving appliances and pipes, water saving in landscape environment, and utilization of non-tradi......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 50362-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 50362-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 50362-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 50362-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 50362-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 50362-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |