Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 4930-2021 English PDF

US$344.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 4930-2021: Microbeam analysis - Electron probe microanalysis - Guidelines for the specification of certified reference materials(CRMs)
Status: Valid

GB/T 4930: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 4930-2021344 Add to Cart 4 days Microbeam analysis - Electron probe microanalysis - Guidelines for the specification of certified reference materials(CRMs) Valid
GB/T 4930-2008759 Add to Cart 3 days Microbeam analysis -- Electron probe microanalysis -- Guidelines for the specification of certified reference materials (CRMs) Obsolete
GB/T 4930-1993399 Add to Cart 3 days General specification of electron probe microanalysis standard specimen Obsolete

Similar standards

GB/T 4472   GB/T 6283   GB/T 6678   GB/T 9008   GB/T 6488   

Basic data

Standard ID: GB/T 4930-2021 (GB/T4930-2021)
Description (Translated English): Microbeam analysis - Electron probe microanalysis - Guidelines for the specification of certified reference materials(CRMs)
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G04
Word Count Estimation: 18,142
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 4930-2021: Microbeam analysis - Electron probe microanalysis - Guidelines for the specification of certified reference materials(CRMs)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Microbeam analysis-Electron probe microanalysis-Guidelines for the specification of certified reference materials(CRMs) ICS 19.020 CCSG04 National Standards of People's Republic of China Replace GB/T 4930-2008 Microbeam analysis electron probe microanalysis Guidelines for Technical Conditions of Standard Samples (ISO 14595.2014, IDT) Released on 2021-05-21 2021-12-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Preparation of research materials 2 5 Inhomogeneity of materials 2 6 Stability of research materials 6 7 Determination of chemical composition of standard samples 7 8 Preparation, packaging, transportation and storage of standard samples 7 9 Standard sample certificate 8 Appendix A (informative) Example of calculation process for statistical evaluation of non-uniformity data 9 Appendix B (Normative) Standard sample classification for electron probe microanalysis 11 Appendix C (Informative) Sample Certificate of Electron Probe Microanalysis Standard Sample 12 Reference 13

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces GB/T 4930-2008 "Guidelines for the Technical Conditions of Microbeam Analysis Electron Probe Analysis Standard Samples", and Compared with GB/T 4930-2008, in addition to editorial changes, the main technical changes are as follows. a) "The amount of research material must be sufficient to prepare about.200 sets of standard samples" is changed to "The amount of research material should be sufficient for the standard sample Preparation" (see 4.1, 4.1 of the.2008 edition); b) Replace the note with the text. Delete the first paragraph "Based on these factors, there is no detailed regulation on the sampling sample size here, so that Analysts flexibly design testing procedures" (see 5.2, 5.2 of the.2008 edition); c) Added "(or a suitable and well-characterized composite sample, in which overlap will not cause problems)" (see 5.3); d) "For an energy spectrometer, the dead time should be set at 30%" to "For an energy spectrometer, the dead time should be about 30%" (see 5.3, 5.3 of the.2008 edition); e) "Background" is changed to "Background" (see 5.5, 5.5 of the.2008 edition); f) In order to correct printing errors, the formula ±2 nsnpneC Ss ns-1 􀭡 􀪁 􀭥 􀪁  Change to ±2 1nsnpneC︿2 Ssns-1 B 􀭡 􀪁 􀭥 􀪁 􀪁 Change the formula ±3 nsnpneC Ss ns-1 􀭡 􀪁 􀭥 􀪁  Change to ±3 1nsnpneC︿2 Ssns-1 B 􀭡 􀪁 􀭥 􀪁 􀪁 (See 5.6,.2008 5.6 of the year edition); g) "Note" is changed to "text" (see Appendix A, Appendix A of the.2008 edition). The translation method used in this document is equivalent to ISO 14595.2014 "Technical Conditions for Standard Samples of Microbeam Analysis Electron Probe Microanalysis" Guidelines". This document was proposed and managed by the National Standardization Technical Committee for Microbeam Analysis (SAC/TC38). Drafting organizations of this document. Baowu Special Metallurgy Co., Ltd., Shanghai Power Equipment Complete Design and Research Institute Co., Ltd., Baoshan Iron and Steel Co., Ltd., Industrial Analysis and Testing Center of Guangdong Academy of Sciences. The main drafters of this document. Yao Lei, Zhang Zuogui, Hu Ying, Wu Chaoqun. This document was first published in 1985, revised for the first time in.1993, and revised for the second time in.2008.This is the third revision.

Introduction

Electron probe microanalysis (EPMA) is a quantitative analysis method carried out by the comparative method. It has been widely used in the world and has a certificate. Quasi-samples (CRMs) have a critical impact on the accuracy of quantitative analysis. Therefore, the revision of this document is conducive to the international exchange of electron probe microanalysis and the compatibility of analysis data. This document specifies how to evaluate and select reference materials (RMs)1), how to evaluate the inhomogeneity and stability of standard samples, and gives The chemical composition determination method for the production of EPMA standard samples. The first such standard in the world is GB 4930-1985 "General Technical Conditions for Electron Probe Analysis Standard Samples", which is composed of Drafted by Liu Yongkang, Lin Zhuoran and Zhang Yi, approved by the National Standardization Technical Committee for Electron Probe Analysis Standard Samples (National Standardization Technology for Microbeam Analysis) The predecessor of the Technical Committee) reviewed and passed the report to the National Bureau of Standards (CBS) (the CSBTS of the National Bureau of Technical Supervision and the China National Standardization Committee) The predecessor of SAC) was approved for release and implemented in 1985.This standard was revised for the first time and formed GB/T 4930-1993.The drafters Liu Yongkang, Zhang Yi, Lin Zhuoran, Suo Zhicheng, reviewed by the National Microbeam Analysis Standardization Technical Committee, approved by the State Technical Supervision Bureau, August.1993 Promulgated on the 30th and implemented on July 1,.1994. In.1993, Lin Zhuoran translated GB/T 4930-1993 into English, and was approved by the China Committee of the International Organization for Standardization (ISO /CS, namely CSBTS) applied to the Electronic Probe Branch of the Microbeam Analysis Technical Committee of the International Organization for Standardization (ISO /TC202/SC2) for the establishment of international standards. After many revisions by domestic and foreign peer experts, it was submitted to ISO for approval, and finally formed ISO 14595.2003 Microbeamanalysis-Electron probemicroanalysis-Guidelinesforthespecificationofcertifiedreferencematerials(CRMs). according to The provisions of GB/T 20000.2-2001 are equivalent to using ISO 14595 to replace GB/T 4930-1993, which is equivalent to a revision of the original standard. GB/T 4930-2008 was drafted by Liu Yongkang, Wan Guangquan, Liang Xirong, Yang Qiujian, and was reviewed and approved by the National Microbeam Analysis Standardization Technical Committee. It was reported to SAC for approval and implemented on October 1,.2008. In.2014, the ISO 14595.2003 edition was revised, and finally the ISO 14595.2014 "Microbeamanalysis-Electron probemicroanalysis-Guidelinesforthespecificationofcertifiedreferencematerials(CRMs)". according to According to the provisions of GB/T 20000.2-2009, this document is equivalent to ISO 14595.2014 instead of GB/T 4930-2008, which is equivalent to Revision of GB/T 4930-2008. 1) Reference material (RM) according to the relevant definition in JJF1001-2011.a substance with sufficiently uniform and stable specific characteristics, Its characteristics have been confirmed to be suitable for the intended use in the measurement or in the inspection of the nominal characteristics. Microbeam analysis electron probe microanalysis Guidelines for Technical Conditions of Standard Samples

1 Scope

This document applies to single-phase standard samples (certified reference materials, CRMs) used in electron probe microanalysis (EPMA), and gives The guidelines for the use of standard samples for microanalysis of flat and polished surfaces are introduced. This document does not apply to organic and biological standard samples.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to This document. GB/T 15000.4-2019 Work Guidelines for Standard Samples Part 4.Contents of Certificates, Labels and Attached Documents (ISO Guide 31.2015, IDT)

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Heterogeneity The change in elemental composition value measured from a set of samples. Note. The non-uniformity comes from the measurement between the sample and the sample, the measurement between the micrometer scale in each sample, and the uncertainty of the testing process itself Fixed degree. 3.2 Researchmaterial The physical and chemical characteristics meet the requirements of standard samples, but the details (including chemical composition, Stability and micro-area and macro-inhomogeneity) materials for testing. 3.3 Stability < General> The ability of the sample to resist chemical and physical changes when stored for a long time under normal temperature and pressure. 3.4 Stability \u003cEPMA\u003eThe ability of the material to resist changes in chemical composition when bombarded by an electron beam, that is, the phase resistance observed during the exposure of the sample to the electron beam The ability to change the intensity of characteristic X-rays. 3.5 Uncertainty It characterizes the parameters that are reasonably assigned to the dispersion of the measured value and are related to the measurement result.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 4930-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 4930-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 4930-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 4930-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 4930-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4930-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.