GB/T 42399.3-2023 English PDFUS$674.00 ยท In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 42399.3-2023: Non-destructive testing instruments - Characterization and verification of ultrasonic phased array equipment - Part 3: Combined system Status: Valid
Basic dataStandard ID: GB/T 42399.3-2023 (GB/T42399.3-2023)Description (Translated English): Non-destructive testing instruments - Characterization and verification of ultrasonic phased array equipment - Part 3: Combined system Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N77 Classification of International Standard: 19.100 Word Count Estimation: 34,335 Date of Issue: 2023-03-17 Date of Implementation: 2023-10-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 42399.3-2023: Non-destructive testing instruments - Characterization and verification of ultrasonic phased array equipment - Part 3: Combined system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 19.100 CCSN77 National Standards of People's Republic of China Non-destructive testing instrument phased array ultrasonic equipment Performance and inspection part 3. combined systems Released on 2023-03-17 2023-10-01 implementation State Administration for Market Regulation Released by the National Standardization Management Committee table of contentsPreface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 symbols 2 5 General requirements 3 6 Operating Mode 4 7 Test Equipment 7 8 Group 1 Test 7 8.1 General 7 8.2 Array elements and channels 7 8.2.1 General 7 8.2.2 Channel assignment 8 8.2.3 Relative Sensitivity of Array Elements 8 8.3 Beam characteristics 10 8.3.1 General 10 8.3.2 Unsaturation 10 8.3.3 Beam characteristics of contact probes 11 8.3.4 Beam characteristics of liquid immersion probes 17 8.4 Imaging examination 20 8.4.1 General 20 8.4.2 Positioning of reflectors 20 8.4.3 -6dB spot size 20 8.4.4 Amplitude comparison 21 9 Group 2 Test 21 9.1 General 21 9.2 Appearance inspection of equipment 21 9.2.1 Detection method 21 9.2.2 Acceptance criteria 21 9.3 Relative Sensitivity of Array Elements 22 9.3.1 General 22 9.3.2 Detection method 22 9.3.3 Identifying failed array elements 22 9.3.4 Sensitivity variation compensation 22 9.3.5 Acceptance criteria 22 9.4 Linearity of amplified systems 22 9.4.1 Detection method 22 9.4.2 Acceptance criteria 22 9.5 Virtual Probe Absolute Sensitivity 23 9.5.1 General 23 9.5.2 Detection method 23 9.5.3 Acceptance criteria 23 9.6 Relative Sensitivity of Virtual Probes 23 9.6.1 General 23 9.6.2 Detection method 23 9.6.3 Acceptance criteria 23 9.7 Probe incidence point 24 9.7.1 General 24 9.7.2 Detection method 24 9.7.3 Acceptance criteria 24 9.8 Angle of refraction 24 9.8.1 General 24 9.8.2 Detection method 24 9.8.3 Acceptance criteria 25 9.9 Deflection angles of contact probes 25 9.9.1 General 25 9.9.2 Detection method 25 9.9.3 Report 25 10 System Record Table 25 Appendix A (informative) Test items and acceptance criteria 26 Reference 28forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents" drafting. This document is part 3 of GB/T 42399 "Performance and Inspection of Phased Array Ultrasonic Equipment for Nondestructive Testing Instruments". GB/T 42399 The following parts have been released. --- Part 1.Instruments; --- Part 2.Probes; --- Part 3.Combined system. This document is equivalent to ISO 18563-3.2015 "Performance and inspection of phased array ultrasonic equipment for non-destructive testing - Part 3.Combination system". This document has made the following minimal editorial changes. --- In order to be consistent with the existing standard series, the name of the standard is changed to "Performance and Inspection of Phased Array Ultrasonic Equipment for Nondestructive Testing Instruments No. Part 3.Composite Systems". Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Testing Machine Standardization Technical Committee (SAC/TC122). This document is drafted by. Shantou Ultrasonic Instrument Research Institute Co., Ltd., Guangdong Shantou Ultrasonic Electronics Co., Ltd. Ultrasonic Instrument Branches, Edson (Xiamen) Electronics Co., Ltd., Guizhou Institute of Technology, Liaoning Instrument Research Institute Co., Ltd., Shanghai Materials Research Institute, Zhongshan Vocational and Technical College, China Special Equipment Inspection and Research Institute. The main drafters of this document. Xie Xiaoyu, Zhan Junsheng, Lin Junming, Li Bo, Fu Yang, Wang Lin, Zhang Yifeng, Li Gangyu, Wu Jinhu, Lin Danyuan, Hu Zhenlong.IntroductionLike the A-type conventional detector, the phased array ultrasonic is based on the pulse reflection method for detection, and the same flaw quantitative and qualitative methods are used. bit method. However, the phased array ultrasonic detector is a high-performance digital instrument, which can record the signal of the whole detection process. The system can generate and display high-quality images projected in different directions, so its unique measurement calibration and verification methods need to be specified. Certainly. GB/T 42399 aims to pass the testing methods and acceptance criteria for phased array ultrasonic detectors including instruments, probes and combined systems Standards are stipulated, so as to unify the technical requirements of products, so that they can be better applied in actual production and testing. GB/T 42399 "Performance and Inspection of Phased Array Ultrasonic Equipment for Nondestructive Testing Instruments" is divided into the following three parts. --- Part 1.Instruments. The purpose is to specify the detection frequency of multi-channel phased array ultrasound in the range of 0.5MHz~10MHz The detection method and acceptance criteria of the main technical performance of the detector. --- Part 2.Probes. The purpose is to specify the use of contact method or liquid immersion method, the center frequency range is 0.5MHz~10MHz The detection methods and acceptance criteria for the main technical performance of phased array probes that need to be inspected after fabrication is completed. --- Part 3.Combined system. The purpose is to specify the use of linear phased array probes, contact (with or without wedge) or water immersion, center The performance detection method of phased array combination equipment (that is, connected instruments, probes and cables) with a frequency in the range of 0.5MHz~10MHz laws and acceptance criteria. The three parts of GB/T 42399 "Performance and Inspection of Phased Array Ultrasonic Equipment for Nondestructive Testing Instruments" are independent of each other, but they echo each other and form a into a complete set of standards. Non-destructive testing instrument phased array ultrasonic equipment Performance and inspection part 3. combined systems1 ScopeThis document describes the inspection methods and acceptance criteria for the inspection of combined equipment (ie instruments, probes and connecting cables). This document is applicable to contact type (with or without wedges) or liquid immersion linear array phased array probes with a center frequency of 0.5MHz~10MHz. Ultrasonic testing system. This detection method is applicable to users in the field or workshop environment. Its purpose is to verify that the system is working correctly, Beam characteristics or check for system performance degradation. This test method is not intended to prove the suitability of the system for a particular application, but to Demonstrate the ability of the combined device to generate an ultrasonic sound beam according to the setup. The scope of this document does not include application-specific device calibration, which is generally covered by the testing process. This document does not contain the following. --- Ring array; ---Aperture sequences with different numbers of array elements; --- The settings of transmission and reception are different (such as excitation aperture, effective number of array elements, delay); ---Adopt a single-array unit signal post-processing technology that is more complex than the simple delay rule (for example. full matrix acquisition).2 Normative referencesThe content in the following documents constitutes the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document. ISO 5577 Non-destructive testing ultrasonic testing terminology (Non-destructivetesting-Ultrasonictesting-Vocabula- ry) Note. GB/T 12604.1 Nondestructive Testing Terminology Ultrasonic Testing (ISO 5577.2017, MOD) ISO 18563-1 Performance and inspection of phased array ultrasonic equipment for non-destructive testing - Part 1.Instruments (Non-destructivetes- Note. GB/T 42399.1-2023 Nondestructive Testing Instruments Performance and Inspection of Phased Array Ultrasonic Equipment Part 1.Instruments (ISO 18563-1. 2015, IDT) EN 1330-4 Terminology for nondestructive testing - Part 4.Terminology for ultrasonic testing (Non-destructivetesting-Terminolo- EN16018 Non-destructive testing terminology for phased array ultrasonic testing (Non-destructivetesting-Terminology- EN 16392-2 Performance and inspection of phased array ultrasonic equipment for non-destructive testing Part 2.Probes (Non-destructivetes-3 Terms and DefinitionsThe terms and definitions defined in ISO 5577, EN 1330-4, EN 16018 and the following apply to this document. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 42399.3-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 42399.3-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 42399.3-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 42399.3-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |