GB/T 38812.4-2022 English PDFUS$279.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 38812.4-2022: Direct reduced iron - Determination of metallic iron - Bromine-methanol titrimetric method Status: Valid
Basic dataStandard ID: GB/T 38812.4-2022 (GB/T38812.4-2022)Description (Translated English): Direct reduced iron - Determination of metallic iron - Bromine-methanol titrimetric method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: D31 Classification of International Standard: 73.060.10 Word Count Estimation: 14,177 Date of Issue: 2022-12-30 Date of Implementation: 2023-04-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 38812.4-2022: Direct reduced iron - Determination of metallic iron - Bromine-methanol titrimetric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. ICS 73.060.10 CCSD31 National Standards of People's Republic of China Determination of iron content in direct reduced iron metal Bromine-methanol titration (ISO 5416.2006, MOD) Posted on 2022-12-30 2023-04-01 Implementation State Administration for Market Regulation Released by the National Standardization Management Committee forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents" drafting. This document is Part 4 of GB/T 38812 "Direct Reduced Iron". GB/T 38812 has issued the following parts. --- Part 1.Determination of ferrous content - ferric chloride decomposition potassium dichromate titration method; --- Part 2.Determination of metallic iron content - ferric chloride decomposition potassium dichromate titration method; --- Part 3.Determination of silicon, manganese, phosphorus, vanadium, titanium, copper, aluminum, arsenic, magnesium, calcium, potassium, sodium content Inductively coupled plasma atomic emission spectroscopy; --- Part 4.Determination of metallic iron content - bromine - methanol titration. This document is modified to adopt ISO 5416.2006 "Determination of iron content in direct reduced iron metal - bromine-methanol titration method". Compared with ISO 5416.2006, this document has made the following structural adjustments. --- The chapter "Terms and Definitions" has been added; ---Change the chapter number of reagents, numbering according to the order of use of reagents in the determination method (see Chapter 5, ISO 5416.2006 Chapter 4); --- Deleted 4.7, 5.1, 5.2, Appendix C, Appendix D and Appendix E of ISO 5416.2006. Compared with ISO 5416.2006, this document has many technical differences, and the vertical single Lines (|) are marked. See Appendix A for a list of these technical differences and their causes. Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Iron and Steel Industry Association. This document is under the jurisdiction of the National Iron Ore and Direct Reduced Iron Standardization Technical Committee (SAC/TC317). This document is drafted by. Dalian Customs Technology Center, Lihong Inspection Group Co., Ltd., Guangxi Liuzhou Iron and Steel Group Co., Ltd., Metallurgical Engineering Industry Information Standard Research Institute, Xiamen Xiaoxun New Energy Technology Co., Ltd., Alashankou Customs Technology Center, Guangzhou Customs Technology Center. The main drafters of this document. Hu Xiaojing, Zhang Dongxing, Xiong Xiaoqing, Zeng Ze, Huang Qingli, Wang Lei, Lu Xinming, Li Awei, Zhu Rong, Yang Yu, Liu Qian, He Shuang, Chen Peixian, Gao Xiaoyuan, Zhong Zhiguang, Liu Xiaohang, Li Wei, Xuan Jianwen, Jiang Zhongming, Cong Dongri.IntroductionDirect reduced iron is an essential high-grade raw material for the production of high-quality steel. The content of metallic iron is the main index to measure the quality of direct reduced iron. It indicates the degree of metallization and impurity content of direct reduced iron. Therefore, the determination of metallic iron content has become an important aspect of the quality of direct reduced iron. Test content. Foreign standards (ISO, Britain, France, South Korea, etc.) mostly use bromine-methanol titration method to determine metallic iron in direct reduced iron, which is widely used in practice. The rate is very high, but there is no domestic standard for bromine-methanol titration. Therefore, the formulation of this document can be in line with international standards and has a good comparable Right. At the same time, GB/T 38812 "Direct Reduced Iron" was improved to keep in line with the international standard. In order to ensure the availability of GB/T 38812, the document is compiled into several parts. GB/T 38812 is proposed to consist of the following parts. --- Part 1.Determination of ferrous content - ferric chloride decomposition potassium dichromate titration method; --- Part 2.Determination of metallic iron content - ferric chloride decomposition potassium dichromate titration method; --- Part 3.Determination of silicon, manganese, phosphorus, vanadium, titanium, copper, aluminum, arsenic, magnesium, calcium, potassium, sodium content Inductively coupled plasma atomic emission spectroscopy; --- Part 4.Determination of metallic iron content - bromine - methanol titration. Determination of iron content in direct reduced iron metal Bromine-methanol titration Caution --- Personnel using this document should have formal laboratory work experience. All possible security issues not addressed in this document Therefore, the user is responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated in relevant national laws and regulations.1 ScopeThis document specifies a method for the determination of metallic iron by oxidation-reduction titration by dissolving metallic iron in bromine-methanol. This document is applicable to the determination of metallic iron content in direct reduced iron, and the determination range (mass fraction) is 15% to 95%.2 Normative referencesThe contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 6379.2 Accuracy of measurement methods and results (trueness and precision) - Part 2.Determination of repeatability of standard measurement methods Basic methods of reliability and reproducibility (GB/T 6379.2-2004, ISO 5725-2.1994, IDT) GB/T 6682 Analytical laboratory water specifications and test methods (GB/T 6682-2008, ISO 3696.1987, MOD) GB/T 6730.3 Determination of hygroscopic water in iron ore analysis samples by gravimetric method, Karl Fischer method and mass loss method (GB/T 6730.3-2017, ISO 2596.2006, MOD) GB/T 8170 Numerical rounding off rules and expression and determination of limit values GB/T 12805 Laboratory glass instrument burettes (GB/T 12805-2011, ISO 385.2005, NEQ) GB/T 12806 Laboratory Glass Instruments Single Marked Line Volumetric Flasks (GB/T 12806-2011, ISO 1042.1998, NEQ) GB/T 12808 Laboratory glassware single-marked pipette GB/T 24239 Sampling and sample preparation of direct reduced iron and hot briquetted iron (GB/T 24239-2009, ISO 10835. 2007, IDT)3 Terms and DefinitionsThis document does not have terms and definitions that need to be defined.4 principlesDissolve metallic iron with bromine-methanol mixed solution, filter and separate the residue, add sulfuric acid and hydrogen peroxide to the filtrate to remove bromide and formazan Alcohol, use stannous chloride and titanium trichloride to reduce ferric iron to ferrous iron, use dilute potassium dichromate solution to oxidize the excess reducing agent, and diphenylamine sulfonic acid Sodium is used as an indicator, and it is titrated with potassium dichromate standard solution.5 reagentsUnless otherwise stated in the analysis, only approved reagents of analytical grade were used. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 38812.4-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 38812.4-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 38812.4-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38812.4-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |