GB/T 38121-2023 English PDFUS$724.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 38121-2023: Protection against lightning - Thunderstorm warning systems Status: Valid GB/T 38121: Historical versions
Basic dataStandard ID: GB/T 38121-2023 (GB/T38121-2023)Description (Translated English): Protection against lightning - Thunderstorm warning systems Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: M04 Classification of International Standard: 91.120.40 Word Count Estimation: 40,417 Date of Issue: 2023-05-23 Date of Implementation: 2023-12-01 Older Standard (superseded by this standard): GB/T 38121-2019 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 38121-2023: Protection against lightning - Thunderstorm warning systems---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS91:120:40 CCSM04 National Standards of People's Republic of China GB/T 38121-2023/IEC 62793:2020 Replacing GB/T 38121-2019 Lightning Protection Thunderstorm Warning System Released on 2023-05-23 2023-12-01 implementation State Administration for Market Regulation Released by the National Standardization Management Committee table of contentsPreface I Introduction III 1 Scope 1 2 Normative references 1 3 Terms, Definitions and Abbreviations 2 4 Thunderstorm phases and detectable phenomena for warning5 5 Thunderstorm detector and its performance description 6 6 Alert method 7 7 install 10 8 Maintenance 10 9 Performance Evaluation 11 10 Application of Thunderstorm Warning System 12 Appendix A (Informative) Overview of Lightning Phenomena 13 Appendix B (Informative) Thunderstorm Detection Technology 16 Appendix C (informative) Recommended precautions 18 Appendix D (Informative) Example of Thunderstorm Warning System Evaluation 19 Appendix E (Normative) Test methods for thunderstorm detectors 23 Appendix F (Informative) Application Guide 28 Reference 33forewordThis document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting: This document replaces GB/T 38121-2019 "Thunderstorm Early Warning System for Lightning Protection": Compared with GB/T 38121-2019, except for the structure In addition to adjustments and editorial changes, the main technical changes are as follows: a) The scope of the standard has been changed (see Chapter 1, Chapter 1 of the:2019 edition); b) Deleted the terms "dwell time", "atmospheric electric field meter", "lightning", "lightning strike", "physical damage", "lightning strike point", "thunderstorm" and the corresponding abbreviations Language (see Chapter 3 of the:2019 edition); c) Added the terms "static field detector", "effective alarm rate", "lightning-related conditions", "warning rate", "null alarms", "total number of alarms" and Corresponding abbreviations (see Chapter 3); d) Deleted the abbreviations "EMI", "OI", "RFI", "RFM" and "RF" (see Chapter 3 of the:2019 edition); e) Changed "classification of thunderstorm detectors and their performance" to "description of thunderstorm detectors and their performance", deleted the classification of thunderstorm detectors, added Added the technical parameters of thunderstorm detectors (see Chapter 5, Chapter 5 of the:2019 edition); f) Changed the "Example of one alert" (see Figure 3, Figure 3 of the:2019 edition); g) Change "Early Warning Evaluation" to "Performance Evaluation", and the content of this chapter has been changed (see Chapter 9, Chapter 8 of the:2019 edition); h) The role of the appendix "Test Methods for Thunderstorm Detectors" has been changed from "informative" to "normative" (see Appendix E, Appendix F of the:2019 edition); This document is equivalent to IEC 62793:2020 "Lightning Protection for Thunderstorm Warning System": The following minimal editorial changes have been made to this document: --- In order to coordinate with existing standards, change the name of the standard to "Lightning Protection and Thunderstorm Warning System"; --- For ease of understanding, a note is added to the definition in 3:1:12; --- In order to conform to the usage habits of our country, change "×" in Table 1 to "√"; --- The area shown in the monitoring area (MA) and surrounding area (SA) in Figure 3b) is inconsistent with the legend and has been corrected; --- Correct the denominator in the calculation formula of false alarm rate and effective alarm rate in Appendix D from 20 to 18: According to formula (2), formula (3) and The definition of the total number of alarms (TNA), TNA is the sum of the number of false alarms, valid alarms, and invalid alarms, and the numbers 12 and 12 in Table D:2 The individual case in No: 19 did not issue an alarm and should not be counted in TNA, so TNA should be 18: Please note that some contents of this document may refer to patents: The issuing agency of this document assumes no responsibility for identifying patents: This document is proposed and managed by the National Lightning Protection Standardization Technical Committee (SAC/TC258): This document was drafted by: Chongqing Lightning Protection Center, State Grid Electric Power Research Institute Wuhan Nari Co:, Ltd:, China Railway Science Research Institute Research Institute Group Co:, Ltd: Communication Signal Research Institute, Sichuan Zhongguang Lightning Protection Technology Co:, Ltd:, Guangdong Power Grid Co:, Ltd: Electric Power Science Research Institute, Shanghai Electric Power University, Nanjing Yuantai Intelligent Technology Co:, Ltd:, China Standardization Association, Donghua Engineering Technology Co:, Ltd:, Guangzhou Lightning Protection Center of West Zhuang Autonomous Region, Electric Power Research Institute of State Grid Fujian Electric Power Co:, Ltd:, Chongqing Laiting Lightning Protection Technology Co:, Ltd:, Zhongshan Xinli Lightning Protection Technology Co:, Ltd:, Beijing Building Materials Inspection and Research Institute Co:, Ltd:, Shanghai Geotechnical Engineering Testing Center Co:, Ltd: Company, Shenzhen Keanda Electronic Technology Co:, Ltd:, Shanghai Chenhui Technology Co:, Ltd:, Zhongke Tianji Technology Co:, Ltd:, Thailand Xingshi Weite New Material Technology Co:, Ltd:, Hefei Jiaxun Technology Co:, Ltd:, Guangdong Gold Group Co:, Ltd:, Guangdong Lixin Lightning Protection Technology Co:, Ltd: Co:, Ltd:, Shandong Tianke Lightning Protection Engineering Co:, Ltd: The main drafters of this document: Xu Wei, Ren Zhaohuan, Gu Shanqiang, Cheng Hao, Yao Ximei, Ding Haifang, Xiao Tong, Yuan Yue, He Jing, Yang Guohua, Peng Xiangyang, Bian Xiaoyan, Zhu Xuanzhu, Sheng Weiwei, Wu Dawei, Zhi Yaoling, Fang Chaoying, Zhang Jianpei, Zeng Yu, Wang Xiaohong, Guo Lingyu, Zhang Fan, Li Xiong, Gao Panliang, Yi Xiaoping, Zhou Hongwei, Zhang Song, Yang Chuanlin, He Xihua, Sun Guanqun: The release status of previous versions of this document and the documents it replaces are as follows: ---The first release in:2019 is 38121-2019; --- This is the first revision:IntroductionLightning activities in nature, especially ground lightning, pose a great threat to human life and property: directly or indirectly caused by lightning casualties occur every year: Lightning will have the following effects: ---It can affect large-scale sports, cultural and political activities, and suspend activities and evacuate people if necessary; ---It can affect industrial activities, such as unexpected interruption of production process due to lightning strike and power failure; ---It can interrupt all kinds of transportation, such as people's daily travel, as well as the transmission of energy and information; --- With the widespread use of lightning-sensitive electronic components in industry, transportation and communication industries, the number of lightning strike accidents has increased year by year; ---It may pose a threat to operations with environmental risks, such as operations with sensitive, flammable, explosive or chemical substances; ---It can cause fire: Over the past few decades, related technical systems, including those dedicated to real-time monitoring of natural atmospheric electrical activity and lightning, have been experienced extraordinary development: These systems provide real-time high-quality and valuable information on the occurrence of thunderstorms, if coordinated with detailed action planning tuned for more valuable applications: Although this information allows users to take anticipated temporary precautionary measures, it should be noted that system users need to act in accordance with relevant regulations: All actions to be taken based on the monitoring information are formulated first: The effectiveness of measures depends to a large extent on the risks involved and the proposed measure: This document gives possible measures (see Appendix C): Like many natural phenomena, lightning and thunderstorms are subject to statistical uncertainty: Although it is not possible to obtain the occurrence of a single lightning strike Precise information on time and place, but the statistical parameters identified in this document can help users choose appropriate protective measures: Lightning Protection Thunderstorm Warning System1 ScopeThis document describes the characteristics of a thunderstorm warning system so that measures can be taken to prevent lightning hazards: Both thunderstorm detectors and/or detection networks composed of them (such as lightning location systems) can be used as thunderstorm warning systems: This document specifies the basic requirements for detectors and detection networks used to accurately collect lightning-related parameters and provide real-time information on lightning activities: This document describes the application of the data collected by the above-mentioned detectors and detection networks in the form of early warning and historical data: This document includes: ● A general description of the technologies available for thunderstorm warning systems; ● Guidance on alert methods; ● Informative examples of possible preventive measures: This document does not apply to the following situations: a) Lightning protective devices, such devices as specified in IEC 62305 (all parts) [1]; b) Rain, hail, wind and other related phenomena accompanying thunderstorms; c) Thunderstorm detection technology based on satellite and radar; d) Portable equipment (devices in which the sensor position is not fixed): NOTE: Due to calibration and testing reasons, portable devices may not be sufficient to provide an effective early warning:2 Normative referencesThe contents of the following documents constitute the essential provisions of this document through normative references in the text: Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document: IEC 60068-2-75:2014 Environmental testing Part 2-75: Test method Test Eh: Hammer test (Environmental Note: GB/T 2423:55-2006 Environmental testing for electrical and electronic products Part 2: Test method Test Eh: Hammer test (IEC 60068-2-75: 1997, IDT) Note: GB/T 4208-2017 enclosure protection level (IP code) (IEC 60529:2013, IDT) IEC 61000-6-4 Electromagnetic compatibility (EMC) Part 6-4: Generic standards for emissions in industrial environments [Electromagnetic Note: GB 17799:4-2022 General Standard for Electromagnetic Compatibility Part 4: Emissions in Industrial Environments (IEC 61000-6-4:2018, IDT) IEC 61180 High-voltage test technology definition, test and procedure requirements, test equipment for low-voltage equipment [High-voltagetesttech- Note: GB/T 17627-2019 High-voltage test technology definition, test and procedure requirements, test equipment for low-voltage electrical equipment (IEC 61180:2016, MOD) Note: GB/T 33588:1-2020 Lightning Protection System Components (LPSC) Part 1: Requirements for Connectors (IEC 62561-1:2017, IDT) IEC 62561-4 Lightning protection system components (LPSC) Part 4: Fastener requirements for conductors [Lightningprotection ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 38121-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 38121-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 38121-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38121-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 38121-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 38121-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |