Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 35830-2018 English PDF

US$119.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 35830-2018: Cleaning products -- Determination of triclosan
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 35830-2018119 Add to Cart 3 days Cleaning products -- Determination of triclosan Valid

Similar standards

GB/T 36970   GB/T 36004   GB/T 34855   GB/T 35832   GB/T 35831   

Basic data

Standard ID: GB/T 35830-2018 (GB/T35830-2018)
Description (Translated English): Cleaning products -- Determination of triclosan
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: Y43
Classification of International Standard: 71.100.40
Word Count Estimation: 6,619
Date of Issue: 2018-02-06
Date of Implementation: 2018-09-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 35830-2018: Cleaning products -- Determination of triclosan

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cleaning products-Determination of triclosan ICS 71.100.40 Y43 National Standards of People's Republic of China Determination of triclosan content in detergents Published on.2018-02-06 2018-09-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by China Light Industry Federation. This standard is under the jurisdiction of the National Standardization Technical Committee on Surfactants and Detergents (SAC/TC272). This standard was drafted by. China Daily Chemical Industry Research Institute [National Detergent Quality Supervision and Inspection Center (Taiyuan)], Shenzhen Barger US Biotechnology Co., Ltd., Fuling Entry-Exit Inspection and Quarantine Bureau, Xi'an Kaimi Co., Ltd., Shanxi Energy Product Quality Supervision and Inspection Research Institute. The main drafters of this standard. Wu Jie, Li Hongyu, Li Qing, Yu Wen, Yao Chenzhi. Determination of triclosan content in detergents

1 Scope

This standard specifies the HPLC method for the determination of triclosan in detergents. This standard applies to the determination of triclosan in detergents.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 6682 Analysis Laboratory Water Specifications and Test Methods

3 Principle

The sample is dissolved in the mobile phase, ultrasonically extracted, and the extract is filtered to configure the UV detector or diode array detector for high efficiency Determination of liquid chromatography. According to the determination of the retention time of the measured components, quantification by external standard method.

4 Reagents and materials

Unless otherwise indicated, only analytically pure reagents and secondary water according to GB/T 6682 were used in the analysis. 4.1 Methanol. Chromatographically pure. 4.2 Triclosan (Triclosan, CAS. 3380-34-5, molecular formula. C12H7Cl3O2). Purity greater than or equal to 99%. 4.3 Triclosan stock solution. Precisely and accurately weigh 100mg triclosan (4.2), dissolve in methanol and make up to 100mL, formulated into a concentration A stock solution of 1000 mg/L was stored in a refrigerator at 4°C, and a standard solution was prepared according to the need to prepare a standard solution with appropriate concentration. 4.4 Filter. Organic, 0.45 μm.

5 Instruments and Equipment

5.1 HPLC. Equipped with a diode array or UV detector. 5.2 Analytical balance. The amount of sense is 0.1mg. 5.3 Ultrasonic cleaners. 5.4 Centrifuge. The speed is not less than 4000r/min.

6 Determination

6.1 Sample preparation Weigh 0.5g of liquid or cream sample (solid sample 0.2g) (accurate to 1mg), place in a 25mL volumetric flask, add 15mL The mobile phase was extracted with ultrasound for 20 min, diluted with mobile phase to the mark and mixed. If the solution is cloudy, transfer the volume of the extracted solution to The tube was centrifuged at 4000r/min for 10 min. After centrifugation, the supernatant was filtered through a filter (4.4). The resulting filtrate was determined by high performance liquid chromatography.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 35830-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 35830-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 35830-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 35830-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.