GB/T 35685.1-2017 English PDFUS$184.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35685.1-2017: Low-voltage switchgear and controlgear enclosed equipment -- Part 1: Enclosed switch-disconnectors to provide isolation during repair and maintenance work Status: Valid
Basic dataStandard ID: GB/T 35685.1-2017 (GB/T35685.1-2017)Description (Translated English): Low-voltage switchgear and controlgear enclosed equipment -- Part 1: Enclosed switch-disconnectors to provide isolation during repair and maintenance work Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K30 Classification of International Standard: 29.120.40; 29.130.20 Word Count Estimation: 10,119 Date of Issue: 2017-12-29 Date of Implementation: 2018-07-01 Regulation (derived from): National Standards Bulletin 2017 No. 32 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 35685.1-2017: Low-voltage switchgear and controlgear enclosed equipment -- Part 1: Enclosed switch-disconnectors to provide isolation during repair and maintenance work---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Low-voltage switchgear and controlgear enclosed equipment - Part 1. Enclosed switch-disconnectors to provide isolation during repair and maintenance work ICS 29.120.40; 29.130.20 K30 National Standards of People's Republic of China Low-voltage switchgear and control equipment Part 1. Provided for repair and maintenance work Isolated isolation switch function Part 1.Enclosedswitch-disconnectorstoprovideisolationduring (IEC 62626-1.2014, Low-voltage switching geared and controlgear enclosedequipment-Part 1.Enclosedswitch-disconnectorsoutsidethescopeof IEC 60947-3toprovideisolationduringrepairndmaintenancework, IDT) 2017-12-29 published.2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Categories 2 5 Features 2 6 product information 2 7 normal use, installation and transport conditions 3 8 structural requirements and performance requirements 3 9 Test 4 Reference 6 ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the translation method identical with IEC 62626-1.2014 "Low-voltage switchgear and control equipment Part 1. Enclosed disconnectors that provide isolation in repair and maintenance outside the scope of IEC 60947-3 ". This standard made the following editorial changes. --- Standard name was changed to "low-voltage switchgear and control equipment Part 1. Provide isolation in the maintenance and maintenance work Function of the closed isolation switch. " This standard proposed by the China Electrical Equipment Industry Association. This standard by the National Low Voltage Electrical Standardization Technical Committee (SAC/TC189) centralized. This standard was drafted unit. Shanghai Electric Apparatus Research Institute, Shanghai Electric Branch Electric Technology Co., Ltd., Shanghai Loncin Electric Co., Ltd., Wuxi New Fergus Electrical Technology Co., Ltd., Schneider Electric (China) Co., Ltd. Shanghai Branch, Shanghai Electrical Equipment Testing Institute. The main drafters of this standard. Chen Xueqin, Huang Jingye, Gu Xiang, Ding Fei, Yu Xu, Zhou Bin, Liu Cheng.IntroductionThe enclosed isolating switch referred to in this standard is intended for a variety of purposes, mainly in the repair and cleaning of electrical circuits (especially motor circuits) and Maintenance work to provide electrical equipment isolation. This enclosed disconnector is also referred to as a "service switch" or a "safety switch." "Safety switch" is also used for safety-related positions Off, test switch and other switches not covered in this standard. This standard specifies, in accordance with IEC 60947-3, a closed isolating switch that provides isolation in the maintenance and servicing of electrical equipment Additional requirements. The enclosed isolating switch provided by this standard is generally installed near the isolated electrical appliance and operated by professionals. NOTE Disconnectors do not have to meet the requirements to prevent unintended start-up, especially if there are other sources of energy other than electrical energy. Low-voltage switchgear and control equipment Part 1. Provided for repair and maintenance work Isolated isolation switch function1 ScopeThis standard applies to AC rated voltage does not exceed 1000V, in the load circuit for maintenance, maintenance and cleaning of the enclosed compartment Off the switch. These enclosed disconnectors are derived from the disconnectors in IEC 60947-3 for use in the IEC 60947 series To prevent unintended start-up from occurring, it is not recommended to install remote control or automatic switch. This type of appliance is not intended for use in the circuit Off, fast start and stop or jog load. Note 1. This type of appliance may disconnect the electrical equipment (whether or not it is in normal operation). The enclosed isolating switch in this standard provides electrical equipment (especially in motor circuits) for repair and maintenance work or cleaning work. Isolated. An enclosed disconnector that isolates electrical equipment during repair and maintenance work is also referred to as a "service switch" and provides the following content. a) different grades, see chapter 4; b) the characteristics of each level; c) the minimum test requirements; d) Information that should be indicated on the appliance, or information provided by the manufacturer, such as product samples. Note 2. This standard does not specify the necessary additional requirements for the application of these switches, such as in explosive atmospheres (eg the European ATEX Directive).2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 20138-2006 Protection degree (IK code) of electrical equipment enclosure to external mechanical impact (IEC 62262.2002, IDT) IEC 60050 (all parts) International Electrotechnical Vocabulary (Internationalelectrotechnicalvocabulary) IEC 60947-1-2007 low-voltage switchgear and control equipment Part 1. General (Low-voltagewitchgearandcon- trolgear-Part 1.Generalrules) IEC 60947-1.2007/A1.2010 No. 1 Amendment (Amendment1,2010) Low - voltage switchgear and controlgear - Part 3. Switches, isolators, disconnectors and fuse sets Low-voltage switchgear and controlgear-Part 3. Switches, disconnector, switch-disconnector andfuse-combinationunits) IEC 60947-3.2008/A1.2012 No. 1 Amendment (Amendment1,2012)3 Terms and definitionsIEC 60050-441, IEC 60947-1, IEC 60947-3 and the following terms and definitions apply to this document. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35685.1-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 35685.1-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 35685.1-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35685.1-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |