GB/T 34989-2017 English PDFUS$699.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34989-2017: Connectors -- Safety requirements and tests Status: Valid
Basic dataStandard ID: GB/T 34989-2017 (GB/T34989-2017)Description (Translated English): Connectors -- Safety requirements and tests Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: L23 Classification of International Standard: 31.220.10 Word Count Estimation: 35,338 Date of Issue: 2017-11-01 Date of Implementation: 2018-05-01 Regulation (derived from): National Standard Announcement 2017 No. 29 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 34989-2017: Connectors -- Safety requirements and tests---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Connectors-Safety requirements and tests ICS 31.220.10 L23 National Standards of People's Republic of China Connector safety requirements and tests (IEC 61984.2008, MOD) Posted.2017-11-01 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Technical Information (Electrical Rating) 6 5 Category 6 5.1 General 6 5.2 anti-shock protection classification 6 5.3 Classification by connector 6 5.4 Sort by connector's additional features 7 6 structural requirements and performance 7 6.1 General 7 6.2 logo and identification number 7 6.3 Anti-misinsertion (not interposable) 8 6.4 Protection against electric shock 8 6.5 Ground Protection 9 6.6 Terminals and termination methods 10 6.7 Interlocking device 12 6.8 Anti-aging 12 6.9 Universal Design 12 6.10 Breaking Capacity Connector (CBC) Design 12 6.11 Free Connector Design 12 6.12 Degree of protection (IP code) 13 6.13 Dielectric strength 13 6.14 Mechanical and Electrical Life 13 6.15 Temperature range 14 6.16 Temperature rise 14 6.17 cable clamp 14 6.18 Mechanical strength 15 6.19 Clearances and creepage distances 15 6.20 insulation 16 6.21 Corrosion resistance 17 7 Test 17 7.1 General 17 7.2 Sample Preparation 17 7.3 Performance Test 18 7.4 non-rewirable free connector process test list (routine test) 23 7.5 Test Schedule 23 Appendix A (Informative) Details of the provisions of the information 28 Appendix B (Informative) Connector Supplementary Information 29 References 31 Figure 1 temperature rise test device 20 Figure 2 bending test device 21 Table 1 to protect the conductor or contact with live parts can reach the smallest metal cross-section 10 Table 2 Applicable Terminals and Termination Methods 10 Table 3 Tests for Terminations or Terminations and Termination 11 Table 4 Mechanical and Electrical Life 13 Table 5 Temperature range 14 Table 6 cable clamp test value 15 Table 7 cable clamp test value 19 Table 8 Test voltage 22 Table 9 Number of samples required for testing 23 Table 10 Group A --- Mechanical Tests Table 11 Group B --- life test 25 Table 12 Group C --- temperature test 25 Table 13 Group D --- Climate Test 26 Table 14 Group E --- Degree of protection test 27 Table B.1 Connector Type 29 Table B.2 auxiliary methods of connector classification 30 ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses redrafted Law to amend the use of IEC 61984.2008 "Connector Safety Requirements and Tests." This standard and IEC 61984.2008 technical differences and the reasons are as follows. --- On normative references, this standard made a specific technical differences in adjustment to adapt to China's technical conditions, adjust the situation Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows; ● Equivalent with the international standard GB/T 2421.1 instead of IEC 60068-1; ● Equivalent to the use of international standards GB/T 2423.53 instead of IEC 60068-2-70; ● Equivalent with the international standard GB/T 4210 instead of IEC 60050-581; ● Equivalent with the international standard GB/T 5095.1 instead of IEC 60512-1; ● Equivalent to the use of international standards GB/T 5095.2 instead of IEC 60512-2; ● Equivalent to the use of international standards GB/T 5095.3 instead of IEC 60512-3; ● Equivalent to the use of international standards GB/T 5095.5 instead of IEC 60512-5; ● Equivalent to the use of international standards GB/T 5095.11 instead of IEC 60512-11; ● Equivalent to the use of international standards GB/T 5465.2 instead of IEC 600417; ● Equivalent to the use of international standards GB/T 16842 instead of IEC 61032; ● Equivalent to the use of international standards GB/T 16895.21 instead of IEC 60364-4-41; ● Equivalent to the use of international standards GB/T 17045 instead of IEC 61140; ● Equivalent to the international standard GB/T 18290.2 instead of IEC 60352-2; ● Equivalent to the use of international standards GB/T 18290.5 instead of IEC 60352-5. --- As GB/T 4208-2017 instead of IEC 60529.1989, it will IEC 60529 Chapter 5 of "the use of test force 20N "50mm spherical" contact probe test guards "was changed to." The first characteristic figure is 1, using a test force of 50N ± 5N ball probe test guards "(see 6.4.2.2, 7.5 in Table 14-E1 group); --- As GB/T 4208-2017 instead of IEC 60529.1989, it will IEC 60529 Chapter 5 of "the use of test force 20N test refers to the test guards, "to" the first characteristic number of 2, with a test force of 10N ± 1N articulation Test means protective devices "(see 6.4.1, 6.4.2.3, 6.4.3, 7.5 in Table 14-E1 group). Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This standard by the National Electrical Equipment Standardization Technical Committee Electromechanical Components (SAC/TC166) centralized. This standard was drafted unit. Zhejiang Yonggui Electric Co., Ltd.. The main drafters of this standard. Zhou Tingping, Li Zhaolin, Li Wei. Connector safety requirements and tests1 ScopeThis standard specifies the connector of technical information (electrical rating), classification, structural requirements and performance and testing. This standard applies to no detailed specification or detailed specification reference to the standard safety requirements, rated voltage AC or DC 50V ~ 1000V, contacts rated current not higher than 125A connector. For the rated voltage not higher than 50V connector can use this standard as a reference to use, in this case, the clearance and creepage The distance refers to the provisions of GB/T 16935.1. This standard can also be used as a connector for each contact rated current higher than 125A can be used as a reference. This standard does not apply to existing safety standards in the device (or device) connector.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2421.1 Electrical and Electronic Products Environmental Testing Overview and Guidelines (GB/T 2421.1-2008, IEC 60068-1.1988, IDT) GB/T 2423.53 Environmental testing for electric and electronic products Part 2. Test methods Test Xb. Marked by friction of hands and Print text wear (GB/T 2423.53-2005, IEC 60068-2-70.1995, IDT) GB/T 3956-2008 Cable conductor (IEC 60228.2004, IDT) GB/T 4208-2017 Enclosure Rating (IP Code) (IEC 60529.2013, IDT) GB/T 4210 Electrotechnical terminology Electromechanical components for electronic equipment (GB/T 4210-2015, IEC 60050-581.2008, IDT) GB/T 5095.1 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 1. General (GB/T 5095.1-1997, idtIEC 60512-1) GB/T 5095.2 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 2. General inspection, electrical continuity And contact resistance test, insulation test and voltage stress test (GB/T 5095.2-1997, idtIEC 60512-2) GB/T 5095.3 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 3. Current carrying capacity test (GB/T 5095.3-1997, idtIEC 60512-3) GB/T 5095.5 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 5. Impact test (Free-cell ), Static load test (fixed element), life test and overload test (GB/T 5095.5-1997, idtIEC 60512-5) GB/T 5095.11 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 11. Climate test (GB/T 5095.11-1997, idtIEC 60512-11-1, IEC 60512-11-7, IEC 60512-11-8) Graphical symbols for electrical equipment - Part 2. Graphical symbols (GB/T 5465.2-2008, IEC 60417. 2007, IDT) Sulfur dioxide corrosion test of metals and other inorganic coatings under normal conditions of condensation (ISO 6988-2009). 1985, IDT) GB/T 13140.4-2008 Connecting devices for low voltage circuits for household and similar purposes Part 2. Barbed wire as a standalone unit Particular requirements for connecting devices for insulation type clamping (IEC 60998-2-3-2002, IDT) GB/T 16842 shell and human protective equipment test fixture (GB/T 16842-2008, IEC 61032.1997, IDT) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34989-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34989-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 34989-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34989-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |