GB/T 34606-2017 English PDFUS$359.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34606-2017: Evaluation method of overall energy-saving performance of building envelope Status: Valid
Basic dataStandard ID: GB/T 34606-2017 (GB/T34606-2017)Description (Translated English): Evaluation method of overall energy-saving performance of building envelope Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: P31 Classification of International Standard: 91.060.01 Word Count Estimation: 18,192 Date of Issue: 2017-10-14 Date of Implementation: 2018-05-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 34606-2017: Evaluation method of overall energy-saving performance of building envelope---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Evaluation method of overall energy-saving performance of building envelope ICS 91.060.01 P31 National Standards of People's Republic of China Evaluation Method of Overall Energy Conservation Performance of Building Envelope 2017-10-14 Published 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Requirements 1 5 Overall rating and rating 2 6 single energy-saving performance evaluation 3 7 Evaluation Report 7 Appendix A (Normative) Enclosure structure average heat transfer coefficient calculation method 8 Appendix B (Informative) Building envelope overall energy-saving performance evaluation process and evaluation report format 10 ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the National Building Energy Standardization Technical Committee (SAC/TC452) centralized. This standard drafting unit. China Academy of Building Research, Shenzhen Academy of Building Research Co., Ltd. Shanghai Public Works testing Co., Ltd., South China University of Technology, Sichuan Academy of Building Research, Xi'an University of Architecture and Technology, Shanghai Academy of Building Research (Group) has Co., Ltd., Henan Risheng Integrated Testing Co., Ltd., Liaoning Province Construction Science Institute, Shanghai Pu Gong Detection Technology Co., Ltd., Nanjing Large Construction Engineering Co., Ltd., Harbin Institute of Technology, Anhui Construction Quality Supervision and Inspection Station, Standard Technical Services Sea) Co., Ltd., the State Special Glass Quality Supervision and Inspection Center, Anhui Construction Engineering Testing Institute Co., Ltd., China Metallurgical Construction Research Institute of General Hospital Co., Ltd., China Polyurethane Industry Association, isocyanate professional committee, Guangdong Chong Gao Curtain Wall Engineering Co., Ltd., Wuxi Xing Foam Plastics Co., Ltd., Shanghai Huafeng Pu En polyurethane Co., Ltd., Jiangsu You Niu Shan insulation waterproofing Technology Co., Ltd., Ningbo Jin Kai Stone New Materials Technology Co., Ltd., Fujian Fengda Construction Engineering Co., Ltd., Xi'an Construction Engineering Co., Ltd. Longyan. The main drafters of this standard. Yang Yuzhong, Song Bo, Ren Jun, Cao Yiran, Meng Qinglin, Liu Hui, He Mei, Qiu Tong, Zhang Haifang, Jia Jie, Wang Huichuan, Gong Hongwei, Sun Shijun, Peng Jianhe, Fan Meifeng, Yao Hua, Rong Li, Liu Xin, Dai Xinrong, Hao Zhihua, Li Jianbo, Cui Yang, Xu Ming, Tang Zhiyong, Cheng Shiliang, Lu Deyi, Kang Junru, Chen Qiuming, Liu Xin Yan, Wang Zhongyuan, Jiang Wei, Deng Qinqin, Ye Shaohua. Evaluation Method of Overall Energy Conservation Performance of Building Envelope1 ScopeThis standard specifies the terms and definitions, requirements, overall evaluation and classification of the overall energy-saving performance evaluation method of building envelope structure, single Energy-saving performance evaluation and evaluation report. This standard applies to civil construction envelope overall energy-saving performance evaluation. This standard does not apply to transparent glass curtain wall buildings and large space buildings.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 7106 exterior doors and windows airtight, watertight, wind pressure performance grading and testing methods Specification for thermal design of civil buildings GB 50189 public building energy efficiency design standards GB/T 51140 basic terms of building energy efficiency standards JGJ26 Design Criteria for Energy Efficiency in Residential Buildings in Cold and Cold Areas JGJ/T 132 residential building energy efficiency testing standards3 Terms and definitionsGB/T 51140 and defined by the following terms and definitions apply to this document. 3.1 Building envelope construction buildvelope Interior and exterior separation of buildings, as well as the construction of internal use of space components, including roofing, exterior walls, exterior doors and floor and so on. 3.2 Overall energy saving performance overalenergy-savingperformance Building envelope structure of the thermal performance of the integrated effect. 3.3 Structural thermal bridge thermalbridgesofstructure In the building envelope structure, due to the presence of concrete, metal and other high thermal conductivity materials, resulting in dense heat flux, surface temperature anomalies Site. 3.4 Reference building referencebuilding Use of comparative assessment as a comparison object when the energy efficiency standards meet the requirements of the hypothetical building.4 requirements4.1 The buildings to be evaluated should be checked and accepted for completion, and should have the completed technical files, relevant technical documents and documents. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34606-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34606-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 34606-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34606-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |