GB/T 34082-2017 English PDF
Basic dataStandard ID: GB/T 34082-2017 (GB/T34082-2017)Description (Translated English): Radio monitoring network transfer protocol Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: M10 Classification of International Standard: 35.100.70 Word Count Estimation: 94,921 Date of Issue: 2017-07-31 Date of Implementation: 2017-11-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 34082-2017: Radio monitoring network transfer protocol---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Radio monitoring network transfer protocol ICS 35.100.70 M10 National Standards of People's Republic of China Radio monitoring network transmission protocol 2017-07-31 Posted 2017-11-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword V. Introduction Ⅵ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 instruction identification 2 5 instruction format 3 6 protocol interaction 4 6.1 protocol interaction timing 4 6.2 Establish connection 5 6.3 authorized certification 5 6.4 Session Properties 5 6.5 redirect 5 6.6 Information Release 5 6.7 tasks and priorities 6 7 data frame format 6 7.1 Data Frame Composition 6 7.2 frame first 6 7.3 Message Data 7 7.4 frame tail 8 7.5 Message Extensions and Combinations 7.6 Message Type 8 7.7 frame extension 18 Monitoring business 18 8.1 Frequency Measurement 18 8.2 frequency table scan 20 8.3 Band Scanning 21 8.4 Broadband Measurement 22 8.5 Quadrature Demodulation 23 8.6 Audio Monitoring 24 8.7 single frequency direction 25 8.8 Broadband direction finding 26 8.9 Spatial Spectrum Orientation 27 8.10 TV monitoring 28 8.11 Emergency interventions 29 Manage business 9.1 Device Usage Statistics Query 31 9.2 Monitoring business statistics time query 31 9.3 Location Search 32 9.4 switch machine control 32 9.5 switch machine status inquiry 33 9.6 air conditioning switch machine control 34 9.7 Antenna Control 34 9.8 Business Function Inquiry 35 9.9 Environmental Monitoring 36 9.10 System Time 36 9.11 System self-test 37 9.12 Troubleshooting 37 9.13 Mission Inquiries 38 9.14 User Inquiries 38 9.15 System Serial Number Inquiry 9.16 Configuration Query 39 9.17 Traffic Query 40 9.18 Stop Monitoring 40 10 Radio Monitoring Network Transport Protocol (RMTP) Regulations and Instructions 41 10.1 Instructions 41 10.2 Business Function Instruction Key 41 10.3 monitoring executive station business function description 42 10.4 Enter the keyword 42 10.5 output keyword 44 10.6 Frame Type Keyword 44 10.7 Modem Mode Keyword 45 10.8 Sub Audio Signaling 46 10.9 Monitoring File Formats 47 10.10 log file format 48 Appendix A (Normative) Monitoring Executive Station Business Function Description 49 Appendix B (normative) Monitoring control center and monitoring station coding table 72 References 87 Figure 1 protocol interaction timing diagram 4 Table 1 Function Instruction ID 2 Table 2 string name and description 3 Table 3, the definition of frame 6 Table 4 header definition 7 Table 5 Message Body Definition 7 Table 6, the definition of the end of frame 8 Table 7 Composition of Certification Message 9 Table 8 Composition of request information 9 Table 9 Composition of result data 10 Table 10 Status Code Meaning 11 Table 11 Composition of ITU measurement data 11 Table 12 Composition of spectrum data 11 Table 13 Composition of DPX Spectrum 12 Table 14 Composition of IQ Data 12 Table 15 Signal Identification Data Composition 12 Table 16 Composition of scan data 13 Table 17 Composition of Directional Data 13 Table 18 Composition of audio data 13 Table 19 Composition of time data 14 Table 20 Composition of Location Data 14 Table 21 Composition of System Configuration Information 14 Table 22 Composition of mission information 15 Table 23 Composition of User Information 15 Table 24 Composition of equipment time data 15 Table 25 Traffic Query Data Composition 16 Table 26 Composition of TRACE data 16 Table 27 Composition of self-test data Table 28 System Serial Number Composition 17 Table 29 Composition of Environmental Parameters Frames 17 Table 30 Composition of monitoring service statistics timeframes 17 Table 31 Composition of antenna status response information 18 Table 32 Composition of the original data 18 Table 33 Request Parameters for Frequency Measurement 19 Table 34 Data Response Frame for Frequency Measurement 19 Table 35 Frequency table scan request parameters 20 Table 36 Frequency Response Scanned Data Response Frame 21 Table 37 Frequency sweep request parameters 21 Table 38 Frequency Band Scan Response Data Frame 22 Table 39 Request Parameters for Broadband Measurement 22 Table 40 Data Response Frame for Broadband Measurement 22 Table 41 Orthogonal Demodulation Request Parameters 23 Table 42 Orthogonal Demodulated Data Response Frames 23 Table 43 Request Parameters for Audio Monitoring 24 Table 44 Audio Monitoring Data Response Frames 24 Table 45 Single frequency direction request parameters 25 Table 46 Single frequency DF data response frame 25 Table 47 Request Parameters for Broadband DF 26 Table 48 Data Response Frame for Broadband Direction Finding 27 Table 49 Spatial Spectrum Direction-finding Request Parameters 27 Table 50 Spatial spectrum direction-finding data response frame 28 Table 51 TV monitoring request parameters 28 Table 52 Monitoring Channel Code 29 Table 53 TV monitor data response frame 29 Table 54 Request for emergency intervention parameters 30 Table 55 Emergency response data response frame 30 Table 56 Request Parameters for Device Usage Statistics Time Query 31 Table 57 Data Response Frame for Equipment Usage Statistics Query 31 Table 58 Request Parameters for Monitoring Business Time of Statistics Query 32 Table 59 Data Response Frame for Monitoring Business Statistics Time Inquiry 32 Table 60 Location Query Data Response Frame 32 Table 61 Switch-on control request parameter 33 Table 62 Switch Control Data Response Frame 33 Table 63 request parameters for on/off status inquiry Table 64 Switch Status Inquiry Data Response Frame 33 Table 65 Air-conditioning switch machine control request parameters 34 Table 66 Air conditioner control data response frame 34 Table 67 Antenna Control Request Parameters 34 Table 68 Antenna Control Data Response Frame 35 Table 69 Data Response Frame for Business Function Query 35 Table 70 Environmental Monitoring Request Parameters 36 Table 71 Environmental Monitoring Data Response Frame 36 Table 72 System request parameters 36 Table 73 System Response Data Frame 37 Table 74 System self-test data response frame 37 Table 75 Fault response data response frame 38 Table 76 Task Response Data Response Frame 38 Table 77 User Query Data Response Frame 38 Table 78 Data Response Frame for System Serial Number 39 Table 79 Configuration Query Data Response Frame 39 Table 80 Data Response Frame for Traffic Query 40 Table 81 Data Monitoring Frames to Stop Monitoring 40 Table 82 Definition of Task ID 40 Table 83 Business Function Instruction Keywords 41 Table 84 Enter the keyword 42 Table 85 outputs the keyword 44 Table 86 Frame Type Keywords 44 Table 87 Modem Mode Keywords 46 Table 88 Subsonic (CTCSS) Frequency Table 47 Table 89 Digital Subsystem (DCS) Code Table 47 Table 90 Monitoring Document Header 47 Table 91 Log File Data ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard by the Ministry of Industry and Information Technology (Communications) centralized. This standard was drafted unit. National Radio Monitoring Center, Sichuan Provincial Radio Monitoring Station, Beijing Starcom Electronic Technology Co., Ltd., into Duhua Communication Technology Co., Ltd., Xihua University, Chengdu lattice Technology Co., Ltd., Zigong City Radio Monitoring Station. The main drafters of this standard. Huang Jia, Li Chuan, Sun Hao, Yang Xu, Ma Fangli, Chen Tao, Ling Hong, Zhu Xudong, Ao Qian, Liu Zhicai, Tang Yu Lin, Chen Yi-Jun, Zhou Kang surgery, Jia years.IntroductionWith the rapid development of radio monitoring services, multi-channel access to monitoring services has become a trend. In recent years, all walks of life based on shift Mobile communications business is developing rapidly, therefore, combined with the characteristics of the radio monitoring business itself, the existing network infrastructure, equipment, technology and other resources In the system architecture, multi-channel access unified planning. In order to unify the access of radio equipment providers and vigorously promote and develop radio monitoring services, this standard is based on the National Radio Management Agency technical regulations and the actual operational and functional requirements of the existing radio monitoring, monitoring of the radio monitoring equipment available and Management of business input and output interfaces, data frame format for a unified specification. This standard is based on the TCP communication protocol on the application level communication protocol is to solve the data transmission between different radio monitoring system Lose the standard agreement. Different radio monitoring systems provide a standard interface service to the radio monitoring network transmission protocol to allow other System to obtain radio monitoring data, in order to achieve interoperability between radio monitoring systems, and thus achieve the purpose of remote control and networking. Radio monitoring network transmission protocol1 ScopeThis standard specifies the radio monitoring network for equipment remote control and data transmission involved in the commonly used monitoring and management services instruction format And returns the data frame format, and specifies the instruction combination and extension methods. This standard applies to real-time radio monitoring business and related management business. This standard does not apply to the database, data processing tasks scheduling.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 13622 radio management terminology3 Terms and definitionsGB/T 13622 and defined by the following terms and definitions apply to this document. 3.1 Monitoring station radiomonitoringstation Technical equipment and ancillary facilities capable of identifying and locating transmissions and measuring the basic characteristics of the transmission. 3.2 Monitoring implementation remotemonitoringstation Equipment controlled by a monitoring control center to perform monitoring tasks. Is a fixed station, mobile station, mobile station collectively. 3.3 Fixed station fixedremotemonitoringstation Monitoring and enforcement stations set up for monitoring at fixed locations. 3.4 Mobile station mobileremotemonitoringstation A monitoring station that is located in a vehicle and can be monitored while it is moving. 3.5 Removable station portableremotemonitoringstation Monitoring and enforcement stations that can be set up and implemented in different locations on a temporary basis. 3.6 Monitoring control center radiomonitoringcontrolcenter Has the control of multiple monitoring stations for joint monitoring, data collection and statistical analysis, command and scheduling functions of the agency. 3.7 Monitoring Executive host host identifier remotemonitoringstationhostID It is used to identify and distinguish different monitoring execution stations, which can be the code of monitoring execution station, the host name where the monitoring service is located or the monitoring service Host's IP address. ...... |