Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 33863.6-2017 English PDF

US$1379.00 · In stock
Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 33863.6-2017: OPC unified architecture -- Part 6: Mapping
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 33863.6-20171379 Add to Cart 8 days OPC unified architecture -- Part 6: Mapping Valid

Similar standards

GB/T 33009.1   GB/T 33008.1   GB/T 33009.2   GB/T 33863.13   GB/T 33863.9   GB/T 33863.11   

Basic data

Standard ID: GB/T 33863.6-2017 (GB/T33863.6-2017)
Description (Translated English): OPC unified architecture -- Part 6: Mapping
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N10
Classification of International Standard: 25.040
Word Count Estimation: 69,671
Date of Issue: 2017-07-12
Date of Implementation: 2018-02-01
Quoted Standard: IEC/TR 62541-1; IEC/TR 62541-2; IEC 62541-3; IEC 62541-4; IEC 62541-5; IEC 62541-7; ITU-T X.690; ITU-T X.200; ITU-T X.509; SOAP V1.2
Adopted Standard: IEC 62541-6-2011, IDT
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the security model described in GB / T 33863.2, the abstract service definition described in GB / T 33863.4, the data structure defined in GB / T 33863.5, and the OPC unified architecture between the physical network protocols used to implement the OPC UA specification (OPC UA) mapping.

GB/T 33863.6-2017: OPC unified architecture -- Part 6: Mapping

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
OPC unified architecture. Part 6. Mapping ICS 25.040 N10 National Standards of People's Republic of China OPC Unified Architecture Part 6. Mapping (IEC 62541-6.2011, IDT) 2017-07-12 Posted 2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Introduction Ⅶ Introduction Ⅷ 1 Scope 1 2 Normative references 1 3 Terms and Definitions, Abbreviations 2 3.1 Terms and definitions 2 3.2 Abbreviations 3 4 Overview 3 5 data encoding 4 5.1 Overview 4 5.1.1 General 4 5.1.2 Built-in type 5 5.1.3 Guid 5 5.1.4 ExtensionObject 6 5.1.5 Variant 6 5.2 OPC UA Binary 6 5.2.1 Overview 6 5.2.2 Built-in type 7 5.2.2.1 Boolean 7 5.2.2.2 Integer 7 5.2.2.3 FloatingPoint 7 5.2.2.4 String 8 5.2.2.5 DateTime 8 5.2.2.6 Guid 8 5.2.2.7 ByteString 9 5.2.2.8 XmlElement 9 5.2.2.9 NodeId 9 5.2.2.10 ExpandedNodeId 11 5.2.2.11 StatusCode 11 5.2.2.12 DiagnosticInfo 11 5.2.2.13 QualifiedName 12 5.2.2.14 LocalizedText 12 5.2.2.15 ExtensionObject 13 5.2.2.16 Variant 14 5.2.2.17 DataValue 14 5.2.3 Enumerations 15 5.2.4 Arrays 15 5.2.5 Structures 15 5.2.6 Messages 16 5.3 XML 16 5.3.1 Built-in data types 5.3.1.1 Overview 16 5.3.1.2 Boolean 17 5.3.1.3 Integer 17 5.3.1.4 FloatingPoint 17 5.3.1.5 XML Floating Point Support Positive Infinity (INF), Negative Infinity (-INF), and Ambiguous Numeric Results (NaN) Byte stream 17 5.3.1.6 DateTime 17 5.3.1.7 Guid 18 5.3.1.8 ByteString 18 5.3.1.9 XmlElement 18 5.3.1.10 NodeId 18 5.3.1.11 ExpandedNodeId 19 5.3.1.12 StatusCode 20 5.3.1.13 DiagnosticInfo 20 5.3.1.14 QualifiedName 21 5.3.1.15 LocalizedText 21 5.3.1.16 ExtensionObject 21 5.3.1.17 Variant 21 5.3.1.18 DataValue 22 5.3.1.19 Enumerations 23 5.3.2 Arrays 23 5.3.3 Structures 24 5.3.4 Messages 24 6 Security Protocol 24 6.1 Security Handshake 24 6.2 Certificate 26 6.2.1 Overview 26 6.2.2 Application Example Certificate 26 6.2.3 Signing Software Certificate 27 6.3 WS Security Session 28 6.3.1 Overview 28 6.3.2 Marking 29 6.3.3 Request Security Token (RST/SCT) 30 6.3.4 Request Security Token Response (RSTR/SCT) 30 6.3.5 Using SCT 31 6.3.6 Cancel Security Context 32 6.4 OPCUA Security Session 32 6.4.1 Overview 32 6.4.2 MessageChunk structure 32 6.4.3 MessageChunks and error handling 36 6.4.4 Establishing SecureChannels 36 6.4.5 Export Key 37 6.4.6 Verify the Security of Messages Transmission protocol 7.1 OPCUATCP 39 7.1.1 Overview 39 7.1.2 Message Structure 39 7.1.3 Establishing a Connection 42 7.1.4 Close the connection 42 7.1.5 Error Handling 43 7.1.6 Error Recovery 44 7.2 SOAP/HTTP 45 7.2.1 Overview 45 7.2.2 XML Encoding 46 7.2.3 OPCUA binary encoding 46 7.3 Well-known address 47 Standardization Contract 8.1 OPC binary architecture 47 8.2 XML Schema and WSDL 48 Appendix A (Normative) Constants 49 Appendix B (Normative) OPCUA Local Mapping Type Declaration 51 Appendix C (Normative) XML-mapped WSDL 52 Appendix D (Normative) Security Settings Management 53 Figure 1 OPCUA stack overview 4 Figure 2 binary stream encoded integer value 7 Figure 3 Coding floating-point value in binary stream 7 Figure 4 encodes byte stream 8 as a binary stream Figure 5 encodes Guids 8 in a binary stream Figure 6 encodes XmlElements 9 as a binary stream Figure 7 byte stream NodeId 10 Figure 8 Two-byte NodeId 10 Figure 9 Four-byte NodeId 11 Figure 10 Security Handshake 25 Figure 11 Related XMLWeb Services Specifications 28 Figure 12 WS Security Session Handshake Figure 13 OPCUA Security Session MessageChunk 32 Figure 14 OPCUATCP Message Structure 41 Figure 15 Establishing OPCUATCP Connections 42 Figure 16 Closing the OPCUATCP connection 43 Figure 17 Restore OPCUATCP Connection 45 Table 1 built-in data types 5 Table 2 Guid structure 6 Table 3 Supported Floating Point Types 7 Table 4 NodeId component 9 Table 5 NodeId encoding value 9 Table 6 Standard NodeId binary encoding 10 Table 7 Two-byte NodeId binary code 10 Table 8 Four-byte NodeId binary code 11 Table 9 ExpandedNodeId binary code 11 Table 10 DiagnosticInfo Binary Code 12 Table 11 QualifiedName Binary Code 12 Table 12 LocalizedText binary encoding 13 Table 13 ExtensionObject binary code 13 Table 14 Variant Binary Code 14 Table 15 DataValue Binary Code 14 Table 16 OPCUA Binary Code Structure Example 16 Table 17 Integer XML Data Type Mapping 17 Table 18 Floating-point XML Data Type Mapping 17 Table 19 NodeId Components 19 Table 20 ExpandedNodeId component 19 Table 21 enumerates type component 23 Table 22 Security Policy 25 Table 23 Application Instance Certificate 26 Table 24 Signature Software Certificate 27 Table 25 WS- * Namespace prefix 29 Table 26 Mapping of RST/SCT to OpenSecureChannelRequest Table 27 Mapping of RSTR/SCT to OpenSecureChannelResponse Table 28 OPCUA Security Session Message Header 33 Table 29 Security Headers for Asymmetric Algorithms 33 Table 30 Security header for symmetric algorithm 34 Table 31 Sequence header 35 Table 32 OPCUA Security Session Message Footer 35 Table 33 OPCUA Security Session Message Abortment Body 36 Table 34 OPCUA Security Session OpenSecureChannel Services 36 Table 35 Encryption Key Generation Parameters 38 Table 36 OPCUATCP Message Header 39 Table 37 OPCUATCPHelo Message 40 Table 38 OPCUATCP Reply Message 40 Table 39 OPCUATCP Error Messages 41 Table 40 OPCUATCP error code 43 Table 41 WS Addressing Header 46 Table 42 LDS Well-Known Address 47 Table A.1 Assigned to attributes 49 Table D.1 Secured Applications 53 Table D.2 CertificateIdentifier 56 Table D.3 CertificateStoreIdentifier 58 Table D.4 CertificateTrustList 58 Table D.5 CertificateValidationOptions 58 Table D.6 ApplicationAccessRule 59 Table D.7 ApplicationSecurityPolicy 60

Foreword

GB/T 33863 "OPC Unified Architecture" is divided into the following 13 sections. --- Part 1. Overview and concepts; --- Part 2. Safety Model; --- Part 3. Address space model; --- Part 4. Services; --- Part 5. Information model; --- Part 6. Mapping; --- Part 7. Rules; --- Part 8. Data access; --- Part 9. Alarms and conditions; --- Part 10. Procedures; --- Part 11. Historical visits; --- Part 12. Found; --- Part 13. Aggregation. This section GB/T 33863 Part 6. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with IEC 62541-6.2011 "OPC Unified Architecture Part 6. Mapping." The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows. --- GB/T 9387 (all parts) Information Technology Open Systems Interconnection Basic Reference Model (ISO /IEC 7498 All the Department Points, IDT) --- GB/T 16263.1-2006 Information technology ASN.1 encoding rules Part 1 Basic encoding rules (BER), regular series Code Rules (CER) and Atypical Code Rules (DER) Specification (ISO /IEC 8825-1.2002, IDT) --- GB/T 16264.8-2005 Information technology - Open Systems Interconnection Directory Part 8. Public key and attribute certificate framework (ISO /IEC 9594-8.2001, IDT) This part is proposed by China Machinery Industry Federation. This part of the National Industrial Process Measurement Control and Automation Standardization Technical Committee (SAC/TC124) centralized. This part of the drafting unit. Machinery Industry Instrumentation Technology and Economy Institute, Chongqing Chuan Yi Automation Co., Ltd., Shanghai Automation Instrumentation Co., Ltd., Beijing three-dimensional control Technology Co., Ltd., Southwest University, China Tobacco Corporation staff training college. The main drafters of this section. Wang Chengcheng, Ding Yan, Wang Deji, Wang Chunxi, Yao Jie, Zhang Qingjun, Liu Feng, Zhang Chunting, Yan Xiaofeng, Zhao Yan collar.

Introduction

This section provides specifications for OPC Unified Architecture application developers. This standard is given for the development of standard interfaces for analysis and design The standard interface accelerates application development by multiple vendors and seamlessly integrates internal operations. OPC Unified Architecture Part 6. Mapping

1 Scope

This section GB/T 33863 specifies the security model described in GB/T 33863.2, GB/T 33863.4 described in the abstract service Service definition, the data structure defined in ISO /IEC 15001 and the OPC unified shelf used to implement the OPCUA specification Structure (OPCUA) mapping.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. IEC /T R62541-1 OPC Unified Architecture Part 1. Overview and Concepts (OPCunifiedarchitecture-Part 1.O- verviewandconcepts) IEC /T R62541-2 OPC Unified Architecture Part 2. Security Model (OPCunifiedarchitecture-Part 2.Secu- ritymodel) IEC 62541-3 OPC Unified Architecture Part 3. Addressing Model (OPCunifiedarchitecture-Part 3.Ad- dressspacemodel) IEC 62541-4 OPC Unified Architecture Part 4. Services (OPCUnifiedarchitecture-Part 4.Services) IEC 62541-5 OPC Unified Architecture Part 5. Information Architecture (OPCUnifiedarchitecture-Part 5.Informa- tionmodel) IEC 62541-7 OPC Unified Architecture Part 7. Line Rules (OPCUnifiedarchitecture-Part 7.Profiles) ITU-T Rec. H.290 Information technology ASN.1 coding rules Basic coding rules (BERs), regular coding rules (CERs) Code Rules (DER) Specification [Informationtechnology-ASN.1encodingrules.SpecificationofBasicEncoding Rules (BER), Canonical Encoding Rules (CER) andDistinguishedEncodingRules (DER)] ITU-TX.200 Information Technology - Open Systems Interconnection Basic Reference Model (Informationtechnology-OpenSystems Interconnection-BasicReferenceModel) ITU-TX.509 Information technology Open Systems Interconnection Directory Public key and attribute certificate framework (Informationtechnology- OpenSystemsInterconnection-Thedirectory.PublicKey and AttributeCertificateFrameworks) XML Schema Part 1. Structure (Second Edition) [XMLSchemaPart 1.Structures (SecondEdition)] XML Schema Part 2. Data Types (Second Edition) [XMLSchemaPart 2.Datatypes (Second Edition)] SOAPV1.2 Part 1. Message Framework (Second Edition) [SOAPVersion1.2Part 1.MessagingFramework (Second Edition)] SOAPV1.2 Part 2. Accessories (Second Edition) [SOAPVersion1.2Part 2.Adjuncts (Second Edition)] XML encryption syntax and processing (XMLEncryption.XMLEncryptionSyntaxandProcessing) XML Signature .XML Signature Syntax and Processing (Second Edition) [XMLSignature.XML-SignatureSyntaxandPro- cessing (SecondEdition)] WS Security. SOAP Message Security 1.1 (WSSecurity.SOAPMessageSecurity1.1) WS Addressing .Web Service Addressing (WS Addressing) [WSAddressing.WebServicesAddressing (WS-Address- ing)]
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 33863.6-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 33863.6-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 33863.6-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 33863.6-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.