Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 33606-2017 English PDF

US$759.00 ยท In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 33606-2017: Flexible and torsion resistant cables of rated voltages from 6 kV (Um=7.2 kV) up to 35 kV (Um=40.5 kV) for wind power generation
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 33606-2017759 Add to Cart 6 days Flexible and torsion resistant cables of rated voltages from 6 kV (Um=7.2 kV) up to 35 kV (Um=40.5 kV) for wind power generation Valid

Similar standards

GB/T 31489.4   GB/T 33594   GB/T 34016   GB/T 29631   GB/T 33596   

Basic data

Standard ID: GB/T 33606-2017 (GB/T33606-2017)
Description (Translated English): Flexible and torsion resistant cables of rated voltages from 6 kV (Um=7.2 kV) up to 35 kV (Um=40.5 kV) for wind power generation
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 38,396
Date of Issue: 2017-05-12
Date of Implementation: 2017-12-01
Quoted Standard: GB/T 156-2007; GB/T 2423.17-2008; GB/T 2423.18-2012; GB/T 2900.10; GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.13-2008; GB/T 2951.14-2008; GB/T 2951.21-2008; GB/T 2951.31-2008; GB/T 3048.4-2007; GB/T 3048.5-2007; GB/T 3048.8-2007; GB/T 3048.10-2007; G
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the characteristics of the use of twisted flexible cables, product codes, logos, technical requirements, inspection rules, test methods and packaging requirements. This standard applies to high-power wind power equipment in the turbine and tower connections or similar occasions with rated voltage 6 kV ~ 35 kV wind power with twisted flexible cable.

GB/T 33606-2017: Flexible and torsion resistant cables of rated voltages from 6 kV (Um=7.2 kV) up to 35 kV (Um=40.5 kV) for wind power generation


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Flexible and torsion resistant cables of rated voltages from 6 kV (Um = 7.2 kV) up to 35 kV (Um = 40.5 kV) for wind power generation ICS 29.060.20 K13 National Standards of People's Republic of China Rated voltage 6kV (Um = 7.2kV) to 35kV (Um = 40.5kV) Warp - resistant flexible cable for wind power generation Flexibleandtorsionresistantcablesofratedvoltagesfrom6kV (Um = 7.2kV) upto35kV (Um = 40.5kV) forwindpowergeneration 2017-05-12 released 2017-12-01 implementation of the implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 4 Use Features 3 5 code, model, specification and product representation 4 6 conductor 5 7 Insulation 5 8 shield 5 9 metal shield 6 10 three-core cable into the cable and fill 7 11 Sheath 7 12 Test conditions 9 13 routine test 9 14 sample test 10 15 Electrical Type Test 15 16 Non-electrical type test 18 Special Type Test Electrical test after installation 19 cable identification mark 23 Acceptance Rules 21 Cable packaging, transport and storage Appendix A (normative) Semi - conductive shielding resistivity measurement method Appendix B (Normative Appendix) Torsion Test 29 Appendix C (Normative Appendix) Load Test 31 Appendix D (normative) Low temperature bending test of finished cable Appendix E (Normative Appendix) Artificial Climate Aging Test 33 Appendix F (normative) Salt spray test

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by China Electrical Equipment Industry Association. This standard by the National Wire and Cable Standardization Technical Committee (SAC/TC213) centralized. The drafting of this standard. Shanghai Cable Research Institute, Jiangsu on the Cable Group Co., Ltd., Prysmian (Tianjin) Cable Co., Ltd., Jiang Suhangtong Power Cable Co., Ltd., Baosheng Technology Innovation Co., Ltd., Far East Cable Co., Ltd., TBEA (Deyang) Cable Co., Ltd. Co., Ltd., Jiangsu China Coal Cable Co., Ltd., Qingdao Han Cable Co., Ltd., Hengyang Hengfei Cable Co., Ltd., Anhui Lingyu Cable Technology Co., Ltd., Anhui Arima Cable Group Co., Ltd., Zhejiang Wanma Co., Ltd., Zhongtian Technology Equipment Cable Co., Ltd., Zhengzhou Cable Co., Ltd., Xingle Group Co., Ltd., Changzhou Marine Cable Co., Ltd., Le Xinghongqi Cable (Hubei) Co., Ltd., Jiangsu Chen Cable Co., Ltd., Hunan Valin Cable Co., Ltd., Hebei Huatong Cable Group Co., Ltd., National Wire and Cable Quality Supervision Supervisory center. The main drafters of this standard. Fan Yujun, Yuan Jie, Zhang Huiyi, Guan Xinyuan, Fang Quansheng, Wang Chuanbin, Liu Chunfang, Liu Jingguang, Chen Peiyun, Wang Xiaorong, Li Wansong, Deng Jiuwang, Liu Huanxin, Xie Xiangqian, Luo Jun, Yu Jingfeng, Gao Jun, Du Qing, Bai Qingmei, Zhang Gongzhuo, Zhao Wenming, Li Xingchen, Zhu Tao, Xiao Jingcheng, Li Congcong, Chen Jiawei. Rated voltage 6kV (Um = 7.2kV) to 35kV (Um = 40.5kV) Warp - resistant flexible cable for wind power generation

1 Scope

This standard specifies the characteristics of the use of twisted flexible cables, product codes, logos, technical requirements, inspection rules, test methods and packaging Claim. This standard applies to high-power wind power equipment in the turbine and tower connection or similar occasions with rated voltage 6kV ~ 35kV Anti-twist flexible cable for wind power generation.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 156-2007 standard voltage GB/T 2423.17-2008 Environmental testing for electric and electronic products - Part 2. Test methods Test Ka. Salt mist GB/T 2423.18-2012 Environmental tests - Part 2. Test methods Test Kb. Salt mist, alternating (sodium chloride solution) GB/T 2900.10 Electrical terminology GB/T 2951.11-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 11. General test methods Measurement of mechanical properties of thickness and dimensions GB/T 2951.12-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 12. General test methods Thermal aging test method GB/T 2951.13-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 13. General test methods Density measurement method Water absorption test Shrink test GB/T 2951.14-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 14. General test methods Low temperature test GB/T 2951.21-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 21. Elastomer mixtures Test method for ozone resistance - Thermal test of mineral oil GB/T 2951.31-2008 Cables and cables - Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixtures Special test methods - High temperature pressure test - Anti - cracking test GB/T 3048.4-2007 Test methods for electrical performance of wire and cable - Part 4. Conductor DC resistance test Test methods for electrical properties of electric cables and wires - Part 5. Insulation resistance test GB/T Test methods for electrical properties of electric cables and wires - Part 8. AC voltage test GB/T GB/T 3048.10-2007 Test methods for electrical performance of wire and cable - Part 10. Extruded sheath spark test GB/T 3048.11-2007 Test methods for electrical performance of wire and cable - Part 11. Dielectric loss tangent test GB/T 3048.12-2007 Test methods for electrical performance of wire and cable - Part 12. Partial discharge test Test methods for electrical properties of electric cables and wires - Part 13. Impulse voltage test GB/T 3048.13-2007 Conductor of cable GB/T 3956-2008 Test methods for bare wires - Part 2. Dimensions measurement GB/T 4909.2 Tinned copper wire
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 33606-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 33606-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 33606-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 33606-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.