Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 32910.2-2017 English PDF

US$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 32910.2-2017: Data center -- Resource utilization -- Part 2: Setting requirement for key performance indicators
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 32910.2-2017199 Add to Cart 3 days Data center -- Resource utilization -- Part 2: Setting requirement for key performance indicators Valid

Similar standards

GB/T 38665.2   GB/T 38665.1   GB/T 9813.3   GB/T 32910.6   GB/T 32910.4   GB/T 32910.1   

Basic data

Standard ID: GB/T 32910.2-2017 (GB/T32910.2-2017)
Description (Translated English): Data center -- Resource utilization -- Part 2: Setting requirement for key performance indicators
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: L60
Classification of International Standard: 35.020
Word Count Estimation: 10,186
Date of Issue: 2017-07-31
Date of Implementation: 2018-02-01
Quoted Standard: GB/T 2887-2011
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the data center boundary, specifies the key performance indicators (KPIs) setting requirements, description methods, uses, and gives examples of KPIs. This standard is applicable to the specification and establishment of key performance indicators that govern the full life cycle of the data center (including design, construction, operation and maintenance).

GB/T 32910.2-2017: Data center -- Resource utilization -- Part 2: Setting requirement for key performance indicators


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Data center. Resource utilization. Part 2. Setting requirement for key performance indicators ICS 35.020 L60 National Standards of People's Republic of China Data center resource utilization Part 2. Key Performance Indicators Setup Requirements Part 2.Settingrequirementforkeyperformanceindicators 2017-07-31 Posted 2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Abbreviations 2 5 data center boundary 2 5.1 Overview 2 5.2 Data center boundaries and key performance indicators 2 5.3 Data center physical range 2 5.4 Data center equipment 2 6 key performance indicators 3 6.1 Overview 3 6.2 General Requirements for Key Performance Indicators 3 6.3 Description of Key Performance Indicators Method 4 6.4 The use of key performance indicators 4 6.5 Examples of Key Performance Indicators 4 Appendix A (Informative) Power Efficiency EEUE 6 Appendix B (Informative) Renewable Energy Utilization REF 7

Foreword

GB/T 32910 "Data Center Resource Utilization", is currently intended to include the following sections. --- Part 1. Terms; --- Part 2. Key performance indicators set requirements; --- Part 3. Energy efficiency requirements and measurement methods; This section GB/T 32910 Part 2. This section drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This part of the National Information Technology Standardization Technical Committee (SAC/TC28) and focal point. This part of the drafting unit.China Electronics Standardization Institute, State Grid Corporation of information and communication branch, the National Development and Reform Commission Institute of Energy Institute, Inspur Electronic Information Industry Co., Ltd., Huawei Technologies Co., Ltd., Tsinghua University, Lanzhou University of Technology, the state State Administration of Customs, National Energy Administration Information Center, Standardization Information Center of China National Standardization Administration, People's Bank of China, Guizhou Gui'an New District Management Committee, China Mobile Communications Corporation, Beijing Branch Science and Technology Co., Ltd., Beijing Forestry University, Universal Data Services Co., Ltd., ZTE Corporation, Shanghai Academy of Building Research, Beijing satisfied that the abundance of Science and Technology Development Co., Ltd., Beijing Tonghe real Yi Telecommunication Science and Technology Institute Co., Ltd., Beijing Kehai Induced Technology Co., Ltd., Section can race (Beijing) Technology Co., Ltd. The main drafters of this section. Gao Linpeng, Lu Junfeng, Feng Shengbo, Li Zhen, Liu Yu, Huang Qunji, Chen Wei, Shen Qihui, Guihua, Zhao Jizhi, Li Daozheng, Lin Li, Zhao Bingzhen, Wen Jinghua, Chen Jieyun, Yang Jianrong, Gao Shumin, Feng Jianchao, Zhao Jing, Hu Xiongwei, Wang Wei, Zhao Hui, Liu Xiaohui, Ma Jiang, Tian Shouhui, Zheng Zhu Ling, Wang Lijian, Guo Xin, Zhao Jiang, plain, Hu Jie. Data center resource utilization Part 2. Key Performance Indicators Setup Requirements

1 Scope

This part of GB/T 32910 defines the data center boundaries, provides the key performance indicators (KPI) set requirements, description methods, with En route, and gives examples of KPIs. This section applies to the specification of the data center life cycle (including design, construction, operation and maintenance and other stages) key performance indicators described And build.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. General specifications for computerized premises GB/T 2887-2011

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Data center energy consumption datacenterenergyconsumption The total amount of energy actually consumed by data center equipment or systems over a period of time. NOTE The energy sources mentioned in this section generally convert the energy consumed by the equipment or system into electric energy for unitary calculation in kW · h. 3.2 Data center energy efficiency datacenterenergyefficiency The ratio of energy output to input in a data center. Note. The above energy can be converted into electricity for unified calculation. 3.3 Data Center Resource Utilization Key Performance datacenterresourceutilizationkeyperformance A series of data accurately reflect the performance of the data center on the utilization of resources. 3.4 Data center key performance indicators datacenterkeyperformanceindicator A measure of the utilization of one or more system resources in the data center. 3.5 Data center resource efficiency datacenterresourceefficiency The ratio of system or device output to the corresponding resource consumption in a data center. Note. When calculating resource efficiency, you may be concerned about the different outputs and different resource consumption of different specific systems or devices, so the ratio of output to consumption There may be different units.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32910.2-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32910.2-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32910.2-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32910.2-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.