Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 3286.12-2023 English PDF

US$249.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 3286.12-2023: Methods for chemical analysis of limestone and dolornite - Part 12: Determination of potassium oxide and sodium oxide contents - Flame atomic absorption spectrometry method
Status: Valid

GB/T 3286.12: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 3286.12-2023249 Add to Cart 3 days Methods for chemical analysis of limestone and dolornite - Part 12: Determination of potassium oxide and sodium oxide contents - Flame atomic absorption spectrometry method Valid
GB/T 3286.12-1982RFQ ASK 3 days Chemical analysis of limestone and dolomite--The titanium trichloride-potassium dichromate volumetric method for determination of iron Obsolete

Similar standards

GB/T 3286.11   GB/T 3286.8   GB/T 3286.9   GB/T 3286.10   GB/T 3286.6   GB/T 3286.7   

Basic data

Standard ID: GB/T 3286.12-2023 (GB/T3286.12-2023)
Description (Translated English): Methods for chemical analysis of limestone and dolornite - Part 12: Determination of potassium oxide and sodium oxide contents - Flame atomic absorption spectrometry method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: D52
Classification of International Standard: 73.080
Word Count Estimation: 12,134
Date of Issue: 2023-11-27
Date of Implementation: 2024-06-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 3286.12-2023: Methods for chemical analysis of limestone and dolornite - Part 12: Determination of potassium oxide and sodium oxide contents - Flame atomic absorption spectrometry method



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 73:080 CCSD52 National Standards of People's Republic of China Methods for chemical analysis of limestone and dolomite Part 12: Determination of potassium oxide and sodium oxide content flame atomic absorption spectrometry Published on 2023-11-27 2024-06-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee

Foreword

This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document is Part 12 of GB/T 3286 "Chemical Analysis Methods for Limestone and Dolomite": GB/T 3286 has released the following part: ---Part 1: Determination of calcium oxide and magnesium oxide content by complex titration and flame atomic absorption spectrometry; ---Part 2: Determination of silica content by silicon-molybdenum blue spectrophotometry and perchloric acid dehydration gravimetric method; ---Part 3: Determination of aluminum oxide content by chromium azure S spectrophotometry and complexometric titration; ---Part 4: Determination of iron oxide content by phenanthroline spectrophotometry and flame atomic absorption spectrometry; ---Part 5: Determination of manganese oxide content by periodate oxidation spectrophotometry; ---Part 6: Determination of phosphorus content by phosphorus molybdenum blue spectrophotometry; ---Part 7: Determination of sulfur content in tube furnace combustion-potassium iodate titration method, high-frequency combustion infrared absorption method and barium sulfate gravimetric method; ---Part 8: Gravimetric method for determination of loss on ignition; ---Part 9: Determination of carbon dioxide content by caustic soda asbestos absorption gravimetric method; ---Part 10: Determination of titanium dioxide content by diantipyridine methane spectrophotometry; ---Part 11: Determination of calcium oxide, magnesium oxide, silica, aluminum oxide and iron oxide content wavelength dispersive X-ray fluorescence light Spectral method (cast glass plate method); ---Part 12: Determination of potassium oxide and sodium oxide content by flame atomic absorption spectrometry; Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents: This document is proposed by the China Iron and Steel Industry Association: This document is under the jurisdiction of the National Steel Standardization Technical Committee (SAC/TC183): This document was drafted by: Ansteel Co:, Ltd:, Ansteel Group Beijing Research Institute Co:, Ltd:, Guangxi Liugang New Materials Technology Co:, Ltd: Company, Metallurgical Industry Information Standards Research Institute, Xiamen Keyuer Technology Co:, Ltd: The main drafters of this document: Liu Dongjie, Pang Keliang, Deng Junhua, Gao Pin, Huang Sheng, Kang Dehua, Wan Shuwei, Wang Lihui, Bi Lian, Tang Wenhua, Zhang Jie, Wang Yiling, Duan Chunfang, Li Ying, Zhu Rong, Tang Yanxiu:

Introduction

GB/T 3286 "Chemical Analysis Methods for Limestone and Dolomite" specifies the chemical analysis of specified characteristics or indicators of limestone and dolomite: The method aims to provide a basis for the analysis of the chemical composition of limestone and dolomite: In order to ensure the usability of the documents, the documents are compiled into several parts: It is divided into parts and is intended to be composed of the following parts: ---Part 1: Determination of calcium oxide and magnesium oxide content by complex titration and flame atomic absorption spectrometry: The purpose is to determine the stone Calcium oxide and magnesium oxide content in limestone and dolomite; ---Part 2: Determination of silica content by silicon molybdenum blue spectrophotometry and perchloric acid dehydration gravimetric method: The purpose is to measure lime Silica content in stone and dolomite; ---Part 3: Determination of aluminum oxide content by chromium azure S spectrophotometry and complexometric titration: The purpose is to measure limestone and white Aluminum oxide content in marble; ---Part 4: Determination of iron oxide content by phenanthroline spectrophotometry and flame atomic absorption spectrometry: The purpose is to measure Iron oxide content in limestone and dolomite; ---Part 5: Determination of manganese oxide content by periodate oxidation spectrophotometry: The purpose is to measure the oxygen in limestone and dolomite Manganese content; ---Part 6: Determination of phosphorus content by phosphorus molybdenum blue spectrophotometry: The purpose is to determine the phosphorus content in limestone and dolomite; ---Part 7: Determination of sulfur content in tube furnace combustion-potassium iodate titration method, high-frequency combustion infrared absorption method and barium sulfate gravimetric method: The purpose is to determine the sulfur content in limestone and dolomite; ---Part 8: Gravimetric method for determination of loss on ignition: The purpose is to determine the ignition loss of limestone and dolomite; ---Part 9: Determination of carbon dioxide content by caustic soda asbestos absorption gravimetric method: The purpose is to determine the dioxide content in limestone and dolomite Carbon content; ---Part 10: Determination of titanium dioxide content by diantipyridine methane spectrophotometry: The purpose is to measure limestone and dolomite Medium titanium dioxide content; ---Part 11: Determination of calcium oxide, magnesium oxide, silica, aluminum oxide and iron oxide content wavelength dispersive X-ray fluorescence light Spectral method (cast glass plate method): The purpose is to determine the calcium oxide, magnesium oxide, silica, alumina and oxygen in limestone and dolomite: Iron content; ---Part 12: Determination of potassium oxide and sodium oxide content by flame atomic absorption spectrometry: The purpose is to measure limestone and dolomite Medium potassium oxide and sodium oxide content; ---Part 13: Determination of silicon, manganese, phosphorus, aluminum, titanium, iron and magnesium content by inductively coupled plasma atomic emission spectrometry: Purpose It is used to measure the content of silicon, manganese, phosphorus, aluminum, titanium, iron and magnesium in limestone and dolomite: Methods for chemical analysis of limestone and dolomite Part 12: Determination of potassium oxide and sodium oxide content flame atomic absorption spectrometry Warning---Personnel using this document should have regular laboratory work experience: All possible security issues not addressed in this document It is the user's responsibility to take appropriate safety and health measures and ensure compliance with the conditions stipulated in relevant national laws and regulations:

1 Scope

This document describes a method for the determination of potassium oxide and sodium oxide in limestone and dolomite by flame atomic absorption spectrometry: This document is applicable to the determination of potassium oxide and sodium oxide content in limestone and dolomite: Measuring range (mass fraction): potassium oxide content 0:005%~1:00%, sodium oxide content 0:005%~0:50%:

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document: GB/T 2007:2 General principles for sampling and preparation of bulk mineral products, manual sample preparation methods GB/T 6379:1 Accuracy of measurement methods and results (correctness and precision) Part 1: General principles and definitions GB/T 6379:2 Accuracy of measurement methods and results (correctness and precision) Part 2: Determination of repeatability of standard measurement methods Basic methods of sex and reproducibility GB/T 6682 Specifications and test methods for water used in analytical laboratories GB/T 7728 General rules for flame atomic absorption spectrometry for chemical analysis of metallurgical products GB/T 8170 Numerical rounding rules and expression and determination of limit values GB/T 12806 Laboratory glassware single-marked volumetric flasks GB/T 12807 Graduated pipettes for laboratory glass instruments GB/T 12808 Single-marked pipette for laboratory glass instruments

3 Terms and definitions

There are no terms or definitions to be defined in this document:

4 Principles

Decompose the sample with hydrochloric acid, hydrofluoric acid and perchloric acid, evaporate to nearly dryness, dissolve the salts with hydrochloric acid, and dilute to constant volume: in atomic absorption spectrometer Above, an air-acetylene flame was used to measure the absorbance of potassium and sodium at wavelengths of 766:5nm and 589:0nm respectively, and the calibration curve method was used to analyze Don't calculate the mass fraction of potassium and sodium:
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 3286.12-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 3286.12-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 3286.12-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 3286.12-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 3286.12-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 3286.12-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.