GB/T 32074-2015 English PDFUS$209.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32074-2015: Non-destructive testing -- Test method for ammonia leak testing Status: Valid
Basic dataStandard ID: GB/T 32074-2015 (GB/T32074-2015)Description (Translated English): Non-destructive testing -- Test method for ammonia leak testing Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J04 Classification of International Standard: 19.100 Word Count Estimation: 10,166 Date of Issue: 2015-10-09 Date of Implementation: 2016-06-01 Quoted Standard: GB/T 9445; GB/T 12604.7; GB/T 20737 Regulation (derived from): National Standard Announcement 2015 No.31 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the ammonia leak detection methods and results of the evaluation. This Standard applies to the system and using ammonia leak detection device can be closed and can be used to detect leaks and determine the leak site. GB/T 32074-2015: Non-destructive testing -- Test method for ammonia leak testing---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Ammonia leak detection method NDT) ICS 19.100 J04 National Standards of People's Republic of China Ammonia leak detection method for non-destructive testing Issued on. 2015-10-09 2016-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard non-destructive testing by the National Standardization Technical Committee (SAC/TC56) and focal points. This standard was drafted. China Special Equipment Inspection and Research Institute, Hebei Boiler and Pressure Vessel Supervision and Testing Institute, Nanjing boiler pressure Vessel Inspection and Research Institute, Henan Academy of boiler and pressure vessel safety inspection, Jinan Special Equipment Inspection and Research Institute, Dalian City boiler pressure Vessel Inspection and Research Institute, Anhui Chinese high-tech development limited liability company. The main drafters of this standard. Qin Xianyong, Shen Tian Gong, King of Branch, Kwong Hing high, Zhang Jun Jiao, Chen Yongna, a Lin Yuan, Hu Zhenlong, Hou Xudong, Yecheng, Wang found that Korea column, in Dekay, Lee atlas, Lina, Fang Xuefeng, Zhang camp, Li Feng, bears peaks. Ammonia leak detection method for non-destructive testing1 ScopeThis standard specifies the ammonia leak detection methods and results of the evaluation. This standard applies to the system and using ammonia leak detection device can be closed and can be used to detect leaks and determine the leak site.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 9445 NDT personnel qualification and certification GB/T 12604.7 Terminology for nondestructive testing Leak Detection GB/T 20737 Non-destructive testing - General terms and definitions3 Terms and DefinitionsTerms and definitions GB/T 12604.7 and GB/T 20737 apply to this document defined. 4. Summary Ammonia leak detection technology is the use of ammonia permeability to detect equipment leaks ammonia charging method has high sensitivity, can detect from Some small openings high pressure side to the low pressure side of the penetration of ammonia, and determine the location of the leak. Ammonia leak detection include the following three method. a) filled with 100% ammonia method, this method is not commonly used in the space charge ammonia detection equipment, the low charge ammonia pressure, and can pump it Leak detection vacuum of 93.7kPa about the case; b) filled with 10% to 30% (volume fraction) of ammonia, this method is commonly used in a large space filled ammonia detection equipment, and difficult to reach 93.7kPa vacuum leak detection or vacuum requirements to achieve higher cost of case; c) filled with 1% (volume fraction) of ammonia, this method commonly used in the subject device ammoniated much room situation.5 Safety requirementsThis chapter does not list all of the safety requirements for testing, the use of this standard user security guidelines should be established prior to detection. Detection process safety requirements include at least the following elements. a) detection testing personnel shall comply with the safety requirements of the scene, wear protective clothing and wear protection according to the relevant requirements of the detection site equipment; b) Ammonia is a flammable, explosive gas, the explosive limits of 15% to 18% (volume fraction), the site should be prepared to detect anti-static and fire Explosion-proof measures; c) ammonia toxic, and on-site testing personnel should be prepared to isolate the virus and operational measures; Electronic instruments d) should be of the fire and explosion function; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32074-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 32074-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32074-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32074-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |