GB/T 31955.1-2015: Control and protection system technical specification of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 31955.1-2015379 Add to Cart 4 days Control and protection system technical specification of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor Valid

Similar standards

GB/T 37155.2   DB41/T 848   GB/T 30092   GB/T 24845   GB/T 32518.1   

Basic data

Standard ID: GB/T 31955.1-2015 (GB/T31955.1-2015)
Description (Translated English): Control and protection system technical specification of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K44
Classification of International Standard: 29.240.01
Word Count Estimation: 18,124
Date of Issue: 2015-09-11
Date of Implementation: 2016-04-01
Quoted Standard: GB/T 191; GB/T 2423.3; GB/T 2900.15; GB/T 2900.49; GB 4208; GB/T 7261-2008; GB/T 7268; GB/T 9361; GB/T 11287-2000; GB/T 14285-2006; GB/T 14537-1993; GB/T 14598.3; GB/T 14598.9-2010; GB/T 14598.10; GB/T 14598.13-2008; GB/T 14598.14-2010; GB/T 14598.17-2005; GB/T 14598.18-2012; GB/T 14598.19-2007; GB/T 14598.27; GB/T 17626.8-2006; GB/T 17626.9-2011; GB/T 22386; DL/T 478; DL/T 860.5; DL/T 1193-2012
Regulation (derived from): National Standard Announcement 2015 No.25
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard specifies the UHP grade adjustable Controllable Shunt Reactor (hereinafter: classification controllable high resistance) general technical condition of the protective control system, control function and performance requirements. This Standard applies to the voltage level of 500kV, 750 kV hierarchical power system for use in a controlled high resistance to control and protection system for the design, manufacture and test. Other controllable voltage level hierarchical control and protection system highly resistant to implementation.

GB/T 31955.1-2015: Control and protection system technical specification of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(EHV Controllable Shunt Reactor Control and Protection System Technical specifications - Part 1. Classification adjustable) ICS 29.240.01 K44 National Standards of People's Republic of China EHV Controllable Shunt Reactor Control and Protection System Technical specifications - Part 1. Classification adjustable ofextrahighvoltage-Part 1. Multistagecontroledshuntreactor Issued on. 2015-09-11 2016-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 2 General technical requirements 5 functional and performance requirements 7 6 Test 11 7 Marking and information specified in Annex 13 8 packaging, storage and transportation 14 Appendix A (informative) EHV Controllable shunt reactors high-impedance transformer protection Configuration 15

Foreword

GB/T 31955 "EHV Controllable Shunt Reactor Control and Protection System technical specifications", is expected to be divided into two parts. --- Part 1. Classification adjustable; --- Part 2. magnetron. This section GB/T Part of 131,955. This section drafted in accordance with GB/T 1.1-2009 given rules. This section is proposed and managed by the China Electricity Council. This section drafted by. National Institute of Smart Grid network, China Electric Power Research Institute, China Southern Power Grid Research Institute, North China Electric Power Design Hospital, Northeast Electric Power Design Institute, East China Electric Power Design Institute, Southwest Electric Power Design Institute, State Nuclear Electric Power Planning and Design Institute, the Shaanxi Provincial Power Planning Review Center trial, State Grid Electric Power Company of Qinghai, Gansu Province, State Grid Power Company, State Grid Electric Power Research Institute in Gansu province electric power company, CLP Preco Technology Co., Ltd., Sifang Co., Ltd. Nanjing NARI-RELAYS. The main drafters of this section. Xu Guizhi, Jing Ping, Tong Yang, Zweig, Shen Hong, Introduction for Su Yi, WEN Ji Feng, Xu Xiangdong, Zheng Wei, Wang Zhongyang, Shang Yong, Zhang Fusheng, Han Shun real, Yuan Zhiyi, Wu Yonggang, Guo Jin, Chen Yue, Wangxiang Ping, Wang Lin, Zhao Lin, Fu Chuang. EHV Controllable Shunt Reactor Control and Protection System Technical specifications - Part 1. Classification adjustable

1 Scope

GB/T 31955 provisions of this part of the UHP grade adjustable Controllable Shunt Reactor (hereinafter. classification controllable high resistance) control System protection system general technical conditions, control function and performance requirements. This section applies to the voltage level of 500kV, 750kV hierarchical power system for use in a controlled high resistance to control and protection system provided Design, manufacture and test. Other controllable voltage level hierarchical control and protection system with high resistance can be implemented by reference.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191 Packaging - Pictorial signs GB/T 2423.3 Environmental testing for electric and electronic products Part 2. Test methods experiment Cab. Damp heat test GB/T 2900.15 Electrotechnical terminology transformers, transformers, regulators and reactors GB/T 2900.49 Electrotechnical terminology - Power System Protection GB 4208 housing protection (IP Code) Basic testing method GB/T 7261-2008 protection and automatic safety devices GB/T 7268 secondary circuit of power system control and protection devices with plug and plug-in panel box basic size series GB/T 9361 computer site security requirements GB/T 11287-2000 Electrical relays - Part 21. Measuring relays and protection equipment vibration, shock, bump and seismic Test Section 1. Vibration tests (sinusoidal) GB/T 14285-2006 relaying protection and security automatic device technical regulations GB/T 14537-1993 measure the impact of the collision with relays and protection equipment - GB/T 14598.3 Electrical relays - Part 5. Measuring relays and protection equipment insulation coordination requirements and tests GB/T 14598.9-2010 metric Part 22-3 relays and protection equipment. Electrical disturbance tests --- anti-electromagnetic radiation Degree of disturbance GB/T 14598.10 metric 22-4 Part relays and protection equipment. Electrical disturbance tests - Electrical fast transient/burst immunity Test GB/T 14598.13-2008 Electrical relays - Part 22-1. Electrical disturbance tests measure relays and protection equipment 1MHz burst immunity test GB/T 14598.14-2010 measure 22-2 Part relays and protection equipment. Electrical disturbance tests - Electrostatic discharge tests GB/T 14598.17-2005 Electrical relays - Part 22-6. Electrical relays and protection equipment disturbance tests --- RF field induced immunity to conducted disturbances GB/T 14598.18-2012 measuring relays and protection equipment - Part 22-5. Electrical disturbance tests - Surge immunity test GB/T 14598.19-2007 Electrical relays - Part 22-7. Electrical measuring relays and protection equipment disturbance tests --- Power frequency immunity tests GB 14598.27 measuring relays and protection equipment - Part 27. Product safety requirements
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 31955.1-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 31955.1-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 31955.1-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 31955.1-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.