Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 31926-2015339 Add to Cart 4 days Zinc and aluminum based coatings on steel sheets and strips -- Determination of lead, cadmium and chromium contents -- Glow discharge atomic emission spectrometry method Valid

Similar standards

GB/T 32786   GB/T 31931   GB/T 31927   

Basic data

Standard ID: GB/T 31926-2015 (GB/T31926-2015)
Description (Translated English): Zinc and aluminum based coatings on steel sheets and strips -- Determination of lead, cadmium and chromium contents -- Glow discharge atomic emission spectrometry method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: H11
Classification of International Standard: 77.080.01
Word Count Estimation: 16,156
Date of Issue: 2015-09-11
Date of Implementation: 2016-06-01
Quoted Standard: GB/T 6379.2; GB/T 19502; GB/T 20066
Regulation (derived from): National Standard Announcement 2015 No.25
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard specifies the glow discharge atomic content of lead, cadmium and chromium emission spectrometry. Pure zinc, zinc-iron, zinc-aluminum, aluminum-zinc coating determination of lead and cadmium chromium content of the steel sheet and strip surfaces This Standard applies to 1 ��m ~ 50 ��m coating thickness. Measurement range (mass fraction): Lead: 0.0035% to 0.2%; Cadmium: 0.003% to 0.2%; Cr: 0.002% to 0.02%.

GB/T 31926-2015: Zinc and aluminum based coatings on steel sheets and strips -- Determination of lead, cadmium and chromium contents -- Glow discharge atomic emission spectrometry method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Steel sheet and strip and aluminum zinc-based coating glow determination of lead, cadmium and chromium content of Discharge Atomic Emission Spectrometry) ICS 77.080.01 H11 National Standards of People's Republic of China Steel sheet and strip aluminum and zinc-based coating of lead, Determination of cadmium and chromium content Glow Discharge Atomic Emission Spectrometry lead, cadmiumandchromiumcontens-Glowdischargeatomicemission Issued on. 2015-09-11 2016-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Iron and Steel Association. This standard by the National Steel Standardization Technical Committee (SAC/TC183) centralized. This standard is drafted by. Anshan Iron and Steel Group Corporation. The main drafters of this standard. in Yuan Jun, high-grade, Kang Dehua, Deng Junhua, Wanghai Dan, Li Feng, Xu Chengming. Steel sheet and strip aluminum and zinc-based coating of lead, Determination of cadmium and chromium content Glow Discharge Atomic Emission Spectrometry Warning --- personnel should use this standard regular laboratory work experience. This standard does not point out all possible security asked question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

This standard specifies the glow discharge atomic content of lead, cadmium and chromium emission spectrometry. This standard applies to 1μm ~ 50μm coating thickness of the steel sheet and strip the surface of pure zinc, zinc, iron, zinc, aluminum, lead and cadmium zinc coating of chromium Determination of. Measurement range (mass fraction). Lead. 0.0035% to 0.2%; Cadmium. 0.003% to 0.2%; Cr. 0.002% to 0.02%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat Of the basic methods of reproduction GB/T 19502 Surface chemical analysis - Glow discharge optical emission spectrometry method General GB/T 20066 Steel and iron - Sampling and determination of the chemical composition of the sample with a sample preparation method Principle 3 The cathode having a flat surface of the sample as a glow discharge apparatus, the sample produces the female DC or RF glow discharge apparatus Pole sputtering, atomic measurement sample characteristic spectral line intensities. When the depth of analysis, emission intensity is recorded as a function of time, by means of a calibration curve, The intensity function of time into a function of the mass fraction of the sputtering depth. Known by measuring the composition of the reference sample sputtering rate can be built Li calibration system. According to the intensity of the relationship between line elements in the sample with the concentration calculation software obtained by coating samples were analyzed, the coating to be Measuring the content of the element.

4 Reagents and materials

Discharge gas. typically high purity argon, 99.999% Purity.

5 Instruments

5.1 Overview Glow Discharge Atomic Emission Spectrometer is normally provided by Grimm type in GB/T 19502 or the like described glow discharge source (package Composition containing a DC or RF power supply mode) and simultaneous spectrometer detector. Spectrometer has been adapted to analyze elemental analysis of line. Diameter An anode within the range of 2mm ~ 8mm can be used. Distance between cathode and anode is generally between 0.1mm ~ 0.3mm. Recommended cold
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 31926-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 31926-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 31926-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 31926-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.