GB/T 31364-2015 English PDFUS$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31364-2015: Test methods for main performance of energy dispersive X-ray fluorescence spectrometer Status: Valid
Basic dataStandard ID: GB/T 31364-2015 (GB/T31364-2015)Description (Translated English): Test methods for main performance of energy dispersive X-ray fluorescence spectrometer Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F81 Classification of International Standard: 27.120.99 Word Count Estimation: 14,163 Date of Issue: 2015-02-04 Date of Implementation: 2015-09-01 Quoted Standard: GB/T 4960.6-2008 Regulation (derived from): National Standards Bulletin 2015 No. 3 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the energy nonlinear energy dispersive X-ray fluorescence spectrometer, peak to background ratio, the maximum count rate linearity, energy resolution, repeatability, instability, and the detection limit of the test method. This Standard applies to pipe excitation energy dispersive X-ray fluorescence spectrometer main performance tests, other energy dispersive X-ray fluorescence spectrometer may also refer to use. GB/T 31364-2015: Test methods for main performance of energy dispersive X-ray fluorescence spectrometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Test methods for main performance of energy dispersive X-ray fluorescence spectrometer ICS 27.120.99 F81 National Standards of People's Republic of China Energy dispersive X-ray fluorescence Spectrometer main performance test methods Issued on. 2015-02-04 2015-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Basic requirements 2 5 Performance Test Method 3 Appendix A (informative) Common target elements and K lines characteristic X-ray energy 7 Annex B (informative) Common elements and K lines characteristic X-ray energy 8 Reference 9ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) proposed. This standard by the Institute of Nuclear Industry Standardization. This standard was drafted. Sichuan Institute of Materials and Technology, Jiangsu Skyray Instrument Co., Ltd., Chengdu University of Technology, the nuclear industry standards The Institute, Chinese Academy of Engineering Physics, Jiangsu Science and Technology Co., Ltd. gifted Messina. The main drafters of this standard. too Yang Ming, Yao Dongliang, Fang Fang Lun Wu Qiang, Xiao Chen, Yang Ping, Zhou Jianbin, Yang Suolong, Yang Li Feng.IntroductionEnergy dispersive X-ray fluorescence spectrometer is based on a sample of elements of higher energy beam or particle flow characteristics of X-ray excitation energy use Characterized by direct measurement of the amount of detector element excitation energy and the X-ray intensity, qualitative and quantitative analysis instrument. It is mainly used for smelting Gold, geology, minerals, petroleum, chemical, biological, medical, commodity inspection, criminal investigation, archaeological and other industries and fields. Energy Dispersive X-ray Fluorescence Spectrometer basic structure is as follows. --- High-voltage generator (high voltage power supply); --- X-ray tube or a source of excitation; --- Energy X-ray detector; --- Pulse amplifier; --- Multi-channel pulse analyzer, data processing and output devices. This standard aims to. --- Specification energy dispersive X-ray fluorescence spectrometer main performance test methods, progress and development of the industry; --- Provide technical support for products and product transactions entered into contracts to protect the interests of the supplier and the consumer; --- Useful for measuring the results and their presentation of unity, comparable. Energy dispersive X-ray fluorescence Spectrometer main performance test methods1 ScopeThis standard specifies the energy nonlinear energy dispersive X-ray fluorescence spectrometer, the peak to background ratio, the maximum count rate linearity, energy resolution, Repeatability, instability, and the detection limit of the test method. This standard applies to tube excitation energy dispersive X-ray fluorescence spectrometer main performance tests, other energy dispersive X-ray fluorescence EDS also refer to use.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 4960.6-2008 nuclear science and technology - Part 6. Nuclear instrumentation3 Terms and DefinitionsGB/T 4960.6-2008 defined and the following terms and definitions apply to this document. 3.1 X-ray fluorescence spectrometer X-rayfluorescencespectrometer In high energy particle beam or an element of the sample flow characteristic X-ray excitation, the characteristic lines of each element and its intensity resolution Measure to achieve qualitative and quantitative analysis of the instrument. 3.2 Energy dispersive X-ray fluorescence spectrometer energydispersiveX-rayfluorescencespectrometer With an energy resolution of the detector elements in the sample directly the characteristic spectral lines of X-ray fluorescence spectrometer. 3.3 Background background Spectral response outside the characteristic X-ray energy peaks. 3.4 Deadtime deadtime Multi-channel analyzer can not take time to accept other input signal interval after a single input signal. [GB/T 4833.1-2007, the definition 3.32] 3.5 The total dead time totaldeadtime In measuring time, the sum of the dead time. [GB/T 4833.1-2007, the definition 3.33] 3.6 Real time realtime Multi-channel pulse amplitude analyzer to obtain distribution data actually measured the elapsed time. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31364-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 31364-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 31364-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31364-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |