Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 30845.1-2023 English PDF

US$799.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30845.1-2023: Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements
Status: Valid

GB/T 30845.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 30845.1-2023799 Add to Cart 6 days Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements Valid
GB/T 30845.1-2014RFQ ASK 5 days Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) -- Part 1: General requirements Obsolete

Similar standards

GB/T 36277   GB/T 34130.21   GB/T 34130.1   GB/T 11918.6   GB/T 14048.11   GB/T 30845.2   

Basic data

Standard ID: GB/T 30845.1-2023 (GB/T30845.1-2023)
Description (Translated English): Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K30
Classification of International Standard: 29.120.30
Word Count Estimation: 42,496
Date of Issue: 2023-09-07
Date of Implementation: 2024-04-01
Older Standard (superseded by this standard): GB/T 30845.1-2014
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 30845.1-2023: Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.120.30 CCSK30 National Standards of People's Republic of China Replace GB/T 30845.1-2014 High voltage shore power connection system (HVSC system) With plugs, sockets and marine couplers Part 1.General requirements (IEC 62613-1.2019, MOD) Published on 2023-09-07 2024-04-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee

Table of contents

PrefaceⅠ Introduction III 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 2 4 General Principles 8 5 Standard rating 8 6 Category 9 7 flag 9 8 size 11 9 Protection against electric shock 11 10 Protective grounding measures 13 11 Terminals and Headers 13 12 Locking devices and interlocks 19 13 Aging resistance of rubber and thermoplastic materials 20 14 General structure 20 15 Structure of sockets and marine input sockets 21 16 Structure of marine connector 21 17 Structure of the plug 21 18 Protection level 21 19 Insulation resistance, electrical strength and partial discharge tests 22 20 Normal operation 24 21 temperature rise 25 22 Flexible cables and their connections 26 23 Mechanical strength 28 24 Screws, current-carrying parts and connections 29 25 Heat resistance, flame resistance and tracking resistance31 26 Resistant to corrosion and rust 32 27 Limited short circuit withstand current test 32 28 Electromagnetic compatibility 36 Reference 37

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is Part 1 of GB/T 30845 "Plugs, sockets and marine couplers for high-voltage shore power connection systems (HVSC systems)". GB/T 30845 has released the following parts. ---Part 1.General requirements; ---Part 2.Dimensional compatibility and interchangeability requirements for different types of marine accessories. This document replaces GB/T 30845.1-2014 "Plugs, sockets and marine couplers for high-voltage shore power connection systems (HVSC systems)" Part 1.General Requirements", compared with GB/T 30845.1-2014, in addition to structural adjustments and editorial changes, the main technical changes are as follows. ---The requirements for the number of control contacts have been changed, and the number of control contacts is no longer limited (see Chapter 1); ---Changed the picture, deleted the text in the picture, and changed it to annotation (see Figure 1 and Figure 8, Figure 1 and Figure 2 of the.2014 version); ---Added graphic description table (see Figure 8, Figure 2 of the.2014 version); ---The maximum rated withstand current peak value has been changed. For electrical accessories with a rated current value of 500A, the maximum rated withstand current peak value has been revised. Changed to 63kA (see 27.1,.2014 version of 27.1). This document is modified to adopt IEC 62613-1.2019 "Plugs, sockets and marine couplers for high-voltage shore power connection systems (HVSC systems)" Part 1.General requirements. The technical differences between this document and IEC 62613-1.2019 and their reasons are as follows. --- Added "This document specifies the structure, electrical structure and electrical requirements of plugs, sockets and marine couplers for high-voltage shore power connection systems (HVSC systems). "Technical requirements such as gas performance and mechanical properties" to comply with the requirements of GB/T 1.1 (see Chapter 1); ---Replaced IEC 60228 with normatively quoted GB/T 3956 to adapt to my country's technical conditions and increase operability (see Section 4 Chapter, Chapter 11 and Chapter 22); ---Replaced IEC 60664-1 with normatively quoted GB/T 16935.1 to adapt to my country's technical conditions and increase operability (see 4.1); ---Replaced IEC 60529 with normatively quoted GB/T 4208 to adapt to my country's technical conditions and increase operability (see Section 7 Chapter 9.1, 12.1 and 18.3); ---Added the requirement to identify the number of this document to adapt to my country's technical requirements and increase operability (see 7.1); ---Changed the notes with requirements to the text (see 10.2); ---Replaced IEC 62271-1 with normatively quoted GB/T 11022 to adapt to my country's technical conditions and increase operability (see 19.6); ---Replaced IEC 60068-2-75 with normatively quoted GB/T 2423.55 to adapt to my country's technical conditions and increase operability (see 23.1); ---Replaced IEC 60695-10-2 with normatively cited GB/T 5169.21 to adapt to my country's technical conditions and increase operability (see 25.3); ---Replaced IEC 60695-2-11 with normatively quoted GB/T 5169.11 to adapt to my country's technical conditions and increase operability (see 25.4); ---Replaced IEC 60112 with normatively quoted GB/T 4207 to adapt to my country's technical conditions and increase operability (see 25.5); ---Replaced IEC 60269-1 with normatively quoted GB/T 13539.1 to adapt to my country's technical conditions and increase operability (see 27.2); ---Replaced IEC 60269-2 with normatively quoted GB/T 13539.2 to adapt to my country's technical conditions and increase operability (see 27.2); ---Replaced IEC 60092-354 with normatively quoted GB/T 17755 to adapt to my country's technical conditions and increase operability (see Table 8); ---Replaced IEC 62262 with normatively cited GB/T 20138 to adapt to my country's technical conditions and increase operability (see 23.1); ---Replaced IEC /IEEE80005-1 with normatively cited GB/T 38329.1 to adapt to my country's technical conditions and increase operability Sex (see 22.2); ---The electrical accessories with a rated current value of 500 A have been changed, and the maximum rated withstand current peak value is 63kA, which is consistent with the The requirements of IEC /IEEE80005-1.2019 remain consistent (see 27.1). This document has made the following editorial changes. ---Changed the editorial error in the document, changing "CTI test" to "PTI test" according to GB/T 4207 (see 25.5); ---The editorial errors in the document have been changed, and the "Figure 9 and Figure 10" cited in 27.3 have been changed to "Figure 13 and Figure 14" (see 27.3). Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Technical Committee for Standardization of Electrical Accessories (SAC/TC67). This document was drafted by. China Electrical Apparatus Research Institute Co., Ltd., Jiangsu Jianlong Electric Co., Ltd., Water Transport Section of the Ministry of Transport Research Institute, Bull Group Co., Ltd., Shantou Kerun Electrical Equipment Co., Ltd., Renwa (Shanghai) Industrial Technology Co., Ltd., Xiamen Weien Electric Co., Ltd., Weikai Testing Technology Co., Ltd., Zhenjiang Electrical Equipment Factory Co., Ltd., Nari Group Co., Ltd., Nanjing Canni Technology Industrial Co., Ltd., Mannex Industrial Electric (China) Co., Ltd., Weihai Honglin Electric Power Technology Co., Ltd., Guangdong South China Home Appliance Research Institute, Shenzhen Lingke Electric Co., Ltd., Jiangsu Pinchuang Equipment Technology Co., Ltd., Shenzhen Lorentz Technology Co., Ltd., Weihai COSCO Shipping Heavy Industry Technology Co., Ltd., Guangdong Angyixin Technology Co., Ltd., Zhejiang Fangyuan Inspection Group Co., Ltd., Shaanxi Zhihengdian Appliance Technology Co., Ltd., Shenzhen Precision Technology Co., Ltd., Xi'an Xumai Intelligent Home Appliance Technology Co., Ltd., Zhejiang Yuehua Telecommunications Co., Ltd., Zhejiang Anya Intelligent Technology Co., Ltd., Guangdong Liying Intelligent Technology Co., Ltd., Motor (Guangzhou) New Energy Technology Co., Ltd., Shaanxi Xite Ni Electronics Co., Ltd., Yiwu Baoneng Mold Technology Co., Ltd. The main drafters of this document. Cai Jun, Huang Yibin, Yang Rui, Cai Yingfeng, Ding Liang, Tao Tao, Lin Ping, Zhang Tengfei, Sun Ting, Dai Gang, He Shengli, Ding Li, Wang Yue, Xu Yang, Lai Jing, Lin Shunhua, Gu Ketian, Ruan Jingyi, Wang Jian, Xiang Xianbing, Zhang Qiusheng, Ping Ge, Wang Fuxing, Chen Feng, Wang Sheng, Zhang Weijun, Wu Guangwei, Wang Wenxia, Tian Feng, Nan Shaowei, Ding Chunyan, Wang Tao, Quan Yongde, Zhang Deyin. The previous releases of this document and the standards it replaces are as follows. ---First published as GB/T 30845.1-2014 in.2014; ---This is the first revision.

Introduction

The preparation of this document is mainly to meet the needs of GB/T 38329.1 high-voltage shore power connection system. In this document the terms plug, socket, Marine connectors and marine input sockets are collectively referred to as electrical accessories and are used to transmit power from shore to ships docked in port. The purpose of GB/T 38329.1 is to specify the requirements for enabling ships to connect to high-voltage shore power supply systems through shore-to-ship compatible connections. The ship is as described in GB/T 38329.1. The requirements of the above high-voltage shore power connection system standards adopt the electrical accessories in the GB/T 30845.2 standard leaflet. Of course, for ships However, it may happen that the ship cannot be connected to the high-voltage shore power supply system. Condition. For certain types of ships, the requirements for low-voltage plugs, socket-outlets, marine connectors and marine in-sockets connected to the low-voltage shore power supply system For information, please refer to the GB/T 11918 series of standard requirements. High voltage shore power connection system (HVSC system) With plugs, sockets and marine couplers Part 1.General requirements

1 Scope

This document specifies the structure, electrical performance, mechanical properties of plugs, sockets and marine couplers for high-voltage shore power connection systems (HVSC systems). Performance and other technical requirements. This document applies to equipment with rated current not exceeding 500A, rated operating voltage not exceeding 12kV, frequency 50/60Hz, equipped with control contacts. Three-phase electrical accessories with grounding and single pole (neutral wire). Electrical accessories are mainly used in outdoor and marine environments with ambient temperatures between -25°C and 45°C to connect ships to high voltages. Shore power supply system. Electrical accessories are not intended for use in hazardous locations. For hazardous locations under special conditions, it may be necessary to stipulate additional requirements. Electrical accessories are intended for use only with copper or copper alloy cables. Sockets or marine input sockets installed in electrical equipment or fixed to the electrical equipment are within the scope of this document.

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 2423.55 Environmental testing of electrical and electronic products Part 2.Environmental testing test Eh. Hammer test (GB/T 2423.55-2006,IEC 60068-2-75.1997,IDT) GB/T 3956 Cable conductors (GB/T 3956-2008, IEC 60228.2004, IDT) GB/T 4207 Method for determination of tracking resistance index and relative tracking index of solid insulating materials (GB/T 4207-2022, IEC 60112.2020,IDT) GB/T 4208 Enclosure protection level (IP code) (GB/T 4208-2017, IEC 60529.2013, IDT) GB/T 5169.11 Fire hazard test for electrical and electronic products Part 11.Glow wire/Hot wire basic test method Glowing of finished products Wire flammability test method (GWEPT) (GB/T 5169.11-2017, IEC 60695-2-11.2014, IDT) GB/T 5169.21 Fire hazard test for electrical and electronic products Part 21.Abnormal hot ball pressure test method (GB/T 5169.21-2017,IEC 60695-10-2.2014,IDT) GB/T 11022 Common technical requirements for high-voltage AC switchgear and control equipment standards (GB/T 11022-2020, IEC 62271-1.2017, MOD) GB/T 12706.4-2020 Extruded insulated power cable with rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) Part 4.Test requirements for accessories of power cables with rated voltages from 6kV (Um=7.2kV) to 35kV (Um=40.5kV) (IEC 60502-4.2010, MOD) Note. There is no technical difference between the quoted content of GB/T 12706.4-2020 and the quoted content of IEC 60502-4.2010. GB/T 13539.1 Low-voltage fuses Part 1.Basic requirements (GB/T 13539.1-2015, IEC 60269-1.2009,
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30845.1-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30845.1-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30845.1-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30845.1-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 30845.1-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 30845.1-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.