GB/T 30651-2014 English PDFUS$149.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30651-2014: Test method of flowability of petrolatum tape at high temperature Status: Valid
Basic dataStandard ID: GB/T 30651-2014 (GB/T30651-2014)Description (Translated English): Test method of flowability of petrolatum tape at high temperature Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A29 Classification of International Standard: 25.220.99 Word Count Estimation: 5,515 Date of Issue: 12/31/2014 Date of Implementation: 7/1/2015 Regulation (derived from): National Standards Bulletin 2014 No. 33 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the detection of petrolatum corrosion test method with high-temperature mobility equipment, sampling requirements, test procedures and test results reporting. This Standard applies to petrolatum corrosion at ambient temperature wit GB/T 30651-2014: Test method of flowability of petrolatum tape at high temperature---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Test method of flowability of petrolatum tape at high temperature ICS 25.220.99 A29 National Standards of People's Republic of China Petrolatum corrosion detection method with high-temperature fluidity Issued on. 2014-12-31 2015-07-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee anti-corrosion (SAC/TC381) centralized. This standard was drafted. Institute of Oceanology, Chinese industrial anti-corrosion Technology Association. The main drafters of this standard. HOU Bao-rong, Wang Jing, Zhao Xia, Yang Lihui, Li Yan Tao, Li Hongling, Xiu Tong, Ma Xiumin, Cao Kun, Sun Cong Tao, Wang Hao and Foster. Petrolatum corrosion detection method with high-temperature fluidity1 ScopeThis standard specifies the detection of petrolatum corrosion temperature fluidity with experimental methods of equipment, sampling, test procedures, and test results reported Report requirements. This standard applies to petrolatum corrosion at ambient temperature with 45 ℃ ~ 65 ℃ construction detection adaptability.2 Terms and definitionsThe following terms and definitions apply to this document. 2.1 Petrolatum corrosion with petrolatumtape Non-woven fabric as a carrier, the compound containing rust inhibitors, corrosion inhibitors, thickeners, lubricants, mineral fillers, etc. specially prepared fat immersed Strip corrosion material. 2.2 Temperature fluidity flowabilityathightemperature Petrolatum tape corrosion at ambient temperature for 45 ℃ ~ 65 ℃ conditioning 24h, the release properties of the composite corrosion petrolatum band.3 Reagents and materials3.1 acetone or ethanol. AR. 3.2 Pipe. diameter 50mm, length 300mm.4 InstrumentOvens. range is -20 ℃ ~ 120 ℃, temperature deviation ≤ ± 2 ℃.5 SamplingTake a size of 500mm × 50mm petrolatum corrosion tape as a sample. Step 6 6.1 adjust oven temperature to keep it at (60 ± 2) ℃ or other agreed temperature. 6.2 with gauze dipped in acetone or ethanol to clean steel, remove surface debris, dry surface. 6.3 in the middle of the steel pipe wrapped with two laps sample petrolatum corrosion, remove excess sample, the surface smooth. 6.4 will be wrapped around the pipe is placed on the sample holder, and place a tray below it (Figure 1). 6.5 The entire apparatus placed above regulate the temperature of the thermostatic oven, to maintain the level, 24h after the observation of the presence or absence of complex drip tray. 6.6 while doing three parallel sample detection. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30651-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30651-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 30651-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30651-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |