GB/T 30128-2013 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30128-2013: Textiles -- Testing and evaluation for negative-ion concentration Status: Valid
Basic dataStandard ID: GB/T 30128-2013 (GB/T30128-2013)Description (Translated English): Textiles -- Testing and evaluation for negative-ion concentration Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: W04 Classification of International Standard: 59.080.30 Word Count Estimation: 7,766 Quoted Standard: GB/T 6529 Regulation (derived from): National Standards Bulletin No. 25 of 2013 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies test methods for textiles dynamic anion amount determined by the friction method, and gives an evaluation. This standard applies to all types of textile fabrics and products. This standard does not involve adding material containin GB/T 30128-2013: Textiles -- Testing and evaluation for negative-ion concentration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Textiles. Testing and evaluation for negative-ion concentration ICS 59.080.30 W04 National Standards of People's Republic of China Textiles anion generation amount of testing and evaluation Issued on. 2013-12-17 2014-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Textile Industry Association. The standard basis by the National Textile Standards Technical Committee of Standardization Technical Committee (SAC/TC209/SC1) centralized; This standard was drafted. Textile Standard (Beijing) Inspection and Certification Center Co., Ltd., Hangzhou Paradise Umbrella Group Co., Ltd., Fujian Rui ring Security Technology Co., Ltd. The main drafters. Zhang Hui, Fang Xijiang, Chen Yuli, Heling Jun, Liu Sheng. Textiles anion generation amount of testing and evaluation1 ScopeThis standard specifies the test methods for textiles dynamic amount of negative ions measured by rubbing method, and gives the evaluation. This standard applies to all types of textile fabrics and products. This standard does not address due to the additional material containing radioactive substances in the air of negative ions and inspire safety evaluation textile products.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 6529 Textiles Standard conditioning and testing atmosphere3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Anion negativeions Negatively charged ions in the atmosphere after the capture molecules or atom electronic form, such as OH- (H2O) n and O-2 (H2O) n and the like. 3.2 Anion generation amount negativeionconcentration Textiles inspired by the mechanical friction when the number of negative ions per cubic centimeter to (a/cm3) as a unit. Principle 4 A certain volume of the test cartridge, the sample is mounted on the upper and lower two friction disc, friction under specified conditions, measured by air ions Measured sample and the sample itself, the mutual friction in the unit volume of space to inspire the number of negative ions, negative ions and recording the sample volume Versus time curve.5 Equipment and Materials5.1 air ion measuring instrument Air ion measuring instrument shall meet the following requirements. --- Collected using capacitive inhalation air ions, ion mobility can collect more than 0.15 (cm2/V · s) ions; --- Negative ions can be measured with a resolution of no greater than 10/cm3; --- Operating temperature and relative humidity ranges to meet the requirements of the test conditions; --- Can record the amount of negative change over time curve. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30128-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 30128-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 30128-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30128-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |