GB/T 30040.6-2013 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30040.6-2013: Leak detection systems -- Part 6: Sensors in monitoring wells Status: Valid
Basic dataStandard ID: GB/T 30040.6-2013 (GB/T30040.6-2013)Description (Translated English): Leak detection systems -- Part 6: Sensors in monitoring wells Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G93 Classification of International Standard: 23.020.01; 23.040.99; 29.260.20 Word Count Estimation: 7,760 Quoted Standard: GB 4208; GB/T 30040.1; GB/T 30040.4-2013 Adopted Standard: BS EN 13160-6-2003, NEQ Regulation (derived from): National Standards Bulletin No. 25 of 2013 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the design for storage of flammable, but outlined a flashpoint not exceeding 100��C Class V fuel system leak detection systems, monitoring wells, liquid recognition sensor, vapor sensors and leakage indicating devices. This standard GB/T 30040.6-2013: Leak detection systems -- Part 6: Sensors in monitoring wells---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Leak detection systems Part 6. Sensors in monitoring wells ICS 23.020.01; 23.040.99; 29.260.20 G93 National Standards of People's Republic of China Double tank leak detection system Part 6. Monitoring Wells Sensor Display System Leakdetectionsystems-Part 6. Sensorsinmonitoringwels Issued on. 2013-12-17 2014-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions Overview 4 1 5 monitoring wells 1 6 Liquid recognition sensor 3 7 vapor sensor 3 8 leakage indicating means 3 Configuration monitoring wells 1 2ForewordGB/T 30040 "double-tank leak detection system" is divided into seven sections. --- Part 1. General; --- Part 2. Pressure and vacuum systems; --- Part 3. Tank Liquid media systems; --- Part 4. double or facilities used in anti-leakage gap liquid or vapor sensor systems; --- Part 5. Tank level gauge leak detection systems; --- Part 6. Monitoring Wells sensor display system; --- Part 7. Double gap, anti-seepage lining and general requirements and test methods for anti-leakage jacket. This section GB/T Part of 630,040. This section drafted in accordance with GB/T 1.1-2009 given rules. The technical content portion BSEN13160-6.2003 "leak detection systems - Part 6. Monitoring Wells Sensor Display System" (In English) the same. This part is proposed by the State Administration of Work Safety. This part of the National Security Chemical Safety Production Standardization Technical Committee Technical Committee (SAC/TC288/SC3) centralized. This section is drafted. Beijing casting Hill Technology Co., Ltd., China Special Equipment Inspection and Research Institute, Beijing national production safety hazard Tank Testing Center product. The main drafters of this section. calm, Zhao Yan repair, cold as ice. Double tank leak detection system Part 6. Monitoring Wells Sensor Display System1 ScopeGB/T 30040 provisions of this part of the design for the storage of flammable, but not more than 100 ℃ flash point of the fuel system Ⅴ level leak detection Overview measurement system, monitoring wells, liquid identification sensors, sensor and vapor leakage indicating devices. This section applies to the design store flammable, but not more than 100 ℃ flash point of the fuel system Ⅴ level leak detection system.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4208 housing protection (IP Code) GB/T 30040.1 double-tank leak detection systems - Part 1. General GB/T 30040.4-2013 double-tank leak detection systems - Part 4. Applied leakage prevention facilities or double gap or liquid Vapor Sensor System3 Terms and DefinitionsTerms and definitions GB/T 30040.1 defined apply to this document.4 OverviewGeneral technical requirements in accordance with GB/T 30040.1 requirements.5 monitoring wellsDown 5.1 from the ground monitoring wells drilled formation, its minimum diameter of 300mm. 5.2 If a liquid sensor, the monitoring wells should surface extends down into the following positions further down the depth of at least 1.0m. a) the minimum normal water table; b) the lower end of the tank or pipe. 5.3 Choosing a), b) the lowest point of both. 5.4 If a vapor sensor, monitoring wells should surface extends down into the tank or pipe the lower end of the lowest point and then down at least Depth of 1.0m. 5.5 If there is a normal risk down to the water table monitoring wells above the radiation holes lowest opening 1.0m or less, use steam sensor. 5.6 Monitoring wells shall extend from the surface to the lowest point of the well casing, the sleeve is evenly covered with radiation holes in the vertical and circumferential directions. Distribution of radiation holes should allow the liquid at any height can enter the well, while preventing soil around the entry. Casing should have sufficient strength Degree, regardless of whether there is liquid monitoring wells, should not be damaged under the pressure of the surrounding land. ...... |